Fault And Warning Messages - Datamax I-4206 Operator's Manual

Thermal transfer printer
Hide thumbs Also See for I-4206:
Table of Contents

Advertisement

6.1 Fault and Warning Messages

All printer functions are internally monitored. If a problem (Fault) or a potential
problem (Warning) is detected, the Error Indicator (see Section 4.0.4) will be
illuminated. A corresponding message will be displayed (if not within a branch
of the menu system or in Quick Test Mode). These messages, along with
possible solutions, are described below.
Fault Messages:
Fault Messages receive the highest display priority. If more than one fault is
detected the display will cycle between messages.
Note: To return to normal operation after the printer enters a fault condition,
the fault must be corrected and then the FEED Key must be pressed to
clear the condition.
Displayed Message
35W!PVU!PG!UPMFSBODF
BED!GBVMU
DVUUFS!GBVMU
I-Class
Printer Fault Messages
Description
The printer has
detected a drop in
the 24-volt power
supply.
The printer has
detected an analog
to digital circuit
converter failure.
The printer has
detected a cutter
mechanism fault.
Possible Solution(s)
Try cycling the printer power
'Off' and 'On'. If the fault
does not clear, call for
service.
Try cycling the printer power
'Off' and 'On'. If the fault
does not clear, call for
service.
WARNING! Use extreme
care. Turn 'Off' and unplug
the printer before proceeding.
Examine the cutter for
obstructions and ensure that
the cutter cable is properly
installed.
Plug in and turn 'On' the
printer. Press the FEED Key.
If the fault does not clear, call
for service.
93