4.1.4

Printer Options

MODULES
PRINT DIRECTORY
PRINT FILE
FORMAT MODULE
DELETE FILE
PACK MODULE
PRESENT SENSOR
ENABLED
DISABLED
NOT INSTALLED
I-Class
Memory available for user storage of
graphics, fonts and label formats. (The
physical presence of the respective memory
module must be detected to show the
function selections in the menu system. See
Appendix C for a listing of all possible
modules.)
Prints a label directory of selected, or of all
available modules, the available space on
these modules, the files present, and the type
of module and files.
The user may select from a list of available
files for sample printing.
The user may select from a list of available
modules for formatting – all data will be
erased.
The user may select from a list of available
files for deleting (protected modules will not
appear). Bytes will not be retrieved until the
module that contained the deleted file is
packed.
Packing the module removes files marked as
deleted
and
structures to recover space.
Used for on-demand label dispensing, where
a printed label blocking the sensor will
inhibit further printing until removed. (The
physical presence of the device must be
detected to show the ENABLE/DISABLE
selections.)
Enables the sensor for on-demand printing.
Disables the sensor.
No Present Sensor is detected.