Remote terminal unit (rtu) coin cell battery (6 pages)
Summary of Contents for Emerson FB3000
Page 1
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 Emerson FB3000 RTU LCD Touchpad User Manual Energy and Transportation Solutions...
Page 2
Emerson office. You can also receive the same quality training via our live, interactive Emerson Virtual Classroom and save on travel costs.
FB3000 RTU. This manual describes how to install, configure, and use the Touchpad. After you install the Touchpad in your enclosure and wire it to the FB3000, you access and configure the Touchpad using FBxConnect configuration software (version 3.17 or higher) loaded on a personal computer running Microsoft...
Page 6
(see through connection is permanently configured with a baud rate of 19,200, 1 stop bit, 1 start bit, 8 data bits, and no parity. The Touchpad cannot use the FB3000’s Ethernet connection but Figures 2-4 and 2-5). can be wired to an FB3000 4-port Serial Communications module (see The Touchpad is transreflective.
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 Figure 1-2. FB3000 Touchpad with Open Cover KEY ACK ALARM TOUCH SCREEN TO ACTIVATE To use the Touchpad, open its protective cover and touch the screen. Two light-emitting diodes (LEDs) at the top of the display provide visual signals on the Touchpad’s operational status.
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 Figure 1-4. Initial Touchpad Screens List mode (indicated by the List Mode label at the top of the screen) provides an auto- scrolling list of read-only parameters, which displays up to 48 user-defined parameters (at a user-defined refresh rate) without requiring a log on process.
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 Once configured, the Touchpad display is blank; the green KEY ACK LED blinks once every three seconds to indicate the Touchpad is still active. The Touchpad “awakens” when you touch it and displays either the splash screen or begins scrolling through the List mode displays (if configured).
Page 10
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 Introduction...
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 Chapter 2. Installing the Touchpad This chapter describes how to install the Touchpad in an enclosure or panel that you provide. Locating the Touchpad The Touchpad is delivered as a kit (Touchpad, cable, dielectric plastic template, and instructions for installing the Touchpad).
Touchpad to the FB3000’s Comm 1 or Comm 2 ports. Figures 2-4 show the wiring for an externally powered Touchpad to the FB3000’s Comm 1 port or to the 4-port Communications module. Installing the Touchpad...
Page 13
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 Figure 2-2. Internally Powered Touchpad Wired to FB3000 Comm Port 1 Figure 2-3. Internally Powered Touchpad Wired to FB3000 Comm Port 2 Installing the Touchpad...
Page 14
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 Figure 2-4. Externally Powered Touchpad Wired to FB3000 Comm Port 1 Figure 2-5. Externally Powered Touchpad Wired to 4-port Comm Module Installing the Touchpad...
LCD Touchpad screen: Figure 3-1. FBxConnect LCD Touchpad Screen While the FB3000 is set up to accept the Touchpad, you need to set some parameters to connect the Touchpad to the FB3000. After connecting the Touchpad, you can configure Sections 3-1 through 3-5).
D301935X012 August 2024 Configuring the Communications Port Owner Even though you may have already wired the Touchpad to the FB3000 (or to a 4-port Serial Communications module), you must identify the communications port (COM1 or COM2) the Touchpad uses. From an FBxConnect session select Configure and then Communications.
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 Figure 3-3. Display on Activated Touchpad As soon as the FB3000 configures the communications with the Touchpad, the splash screen displays: Figure 3-4. Emerson Splash Screen Proceed to Sections 3.2 through to configure display options.
Page 18
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 Figure 3-5. LCD Touchpad Screen 2. In the List Mode Status pane, click Display Lists to show the Display List screen: Configuring the Touchpad...
Page 19
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 Figure 3-6. Display List Screen 3. Select a display list (internally, FBxConnect labels the lists DispList_1 through DispList_4). If you are defining display lists for the first time, select a list and give it a tag and description meaningful to your organization 4.
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 6. Complete the Scroll Time field (at the top of the screen) to indicate the number of seconds (between 1 and 255, with 4 seconds as the default) each parameter screen displays on the Touchpad before being replaced by another parameter screen.
Page 21
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 Figure 3-8. Clk Second Charting Screens In this example, the trending value for the Clk Second parameter restarts after 60 seconds. Select Exit three times to redisplay the Touchpad’s main menu.
Page 22
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 Figure 3-9. Display Chart Parameters 2. Select a display list. 3. Select a parameter (use the point picker). 4. Select Enable to activate dynamic charting for this parameter. 5. Provide values for an upper and lower range limit for the chart.
Normal mode is the default operating mode for the Touchpad and requires no configuration. When you open the cover of the Touchpad you typically see the Emerson splash screen: Figure 3-10. Emerson Splash Screen If you have previously configured List mode, when you touch the screen it automatically begins scrolling through a series of parameter screens.
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 Defining Touchpad Users Note For further information on defining usernames, refer to the Adding a User topic in the FBxConnect online help. In Normal mode, touching the screen displays a grid of defined users: Figure 3-12.
Page 25
August 2024 Figure 3-14. FBxConnect Security user details screen 3. Complete the fields: Field Description Protocol Type DNP3 is the default protocol for the FB3000; do not change this value. Username Enter any combination of up to 30 alphanumeric characters Password Enter any combination of up to 32 alphanumeric characters;...
Page 26
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 Configuring the Touchpad...
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 Chapter 4. Using the Touchpad This chapter describes the day-to-day use of the Touchpad in Normal mode. In List mode, the Touchpad scrolls through a series of parameter screens without further intervention.
Page 28
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 3. Enter a PIN. As you enter the first character of the PIN, the screen changes to accommodate the process: Figure 4-4. PIN Screen 4. Click Done when you have entered a PIN. The first Main Menu screen (left side of...
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 Touchpad Screens The Touchpad uses several kinds of screens to present information: menu screens, parameter screens, and dynamic charts. Note System security settings controls which options display on your Touchpad and whether Section 2.6, Configuring Display...
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 4.2.2 Parameter Screens Parameter screens typically display values. A label at the top of a parameter screen (here, List 1) indicating the user list housing that parameter. The bottom of the screen contains...
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 As you enter a new value, the numeric keypad changes (to include a Done option). When you are finished, touch Done. The Touchpad displays a confirmation screen for the edited value: Figure 4-11.
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 The parameter label displays in the upper center of the screen (here, TP) and alternates every four seconds with a display of the units. The current parameter value (here, 76.382) displays in the lower center of the screen.
D301935X012 August 2024 The FB3000 Touchpad supports four user lists, each of which can display up to 16 parameters. Touch a list to begin a sequential display of the parameters (such as MPU Load or Ext Volt) defined for that list: Figure 4-17.
FBxConnect displays these parameters in List mode (see Meter Runs After touching the Meter Runs option on the main menu, you then select a range of meters (the FB3000 supports up to 36 meters) from the Meter Range menu: Using the Touchpad...
Touchpad menus to match the number and variety of meters in your organization. Modules Select the Module option on the main menu to view information for each I/O module installed in the FB3000. The Module menu displays: Using the Touchpad...
Select the comm port assigned to the MVS modules (here, COMM 3): Figure 4-26. 4088B Menu The FB3000 can support up to 10 4088B sensors. Selecting a sensor displays a sequence of detailed parameter screens for primary values and any alarms: Figure 4-27.
I/O Modules Selecting the Slot 2-8 option lot displays a menu of all I/O modules installed on the FB3000 (here, the 8AIDIPI module installed in slot 2), and can be a list of up to 31 modules (for a four-chassis FB3000): Figure 4-28.
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 Charts Select the Chart option on the main menu to view the charting (or “trending”) function for a parameter. Figure 4-31. Chart Menu The Dynamic option enables you to define up to 24 parameters which you can then view as a dynamic trend.
Page 40
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 Figure 4-34. LCD Touchpad Screen 2. Select Display Chart Parameters to open the Display Chart Parameter screen: Figure 4-35. Display Chart Parameter Screen Using the Touchpad...
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 3. Define up to 24 parameters (which display in 6 sequential screens) for the display list. Use the browse button ( ) to select parameters for the chart. Use the Description field to optionally name each chart (up to10 alphanumeric characters).
PID menu: Figure 4-40. PID Menu This menu currently provides a basic method for displaying and changing Proportional, Integral, and Derivative (PID) loops. The FB3000 supports up to eight PID loops. 4.8.1 Displaying Basic PID Loops Select Basic to display the PID loops currently defined in the FB3000: Figure 4-41.
Emerson FB3000 RTU LCD Touchpad User Manual D301935X012 August 2024 Figure 4-42. Basic PID Menu Screen Select Primary to display the primary PV and SP for the PID loop: Figure 4-43. PID Primary Variables Screen Select Mode to switch the PID mode between automatic and manual: ...
Page 44
Emerson and Singapore 128461 the Emerson logo are trademarks and service marks of Emerson Electric Co. All T +65 6777 8211| F +65 6777 0947 other marks are the property of their respective owners.
Need help?
Do you have a question about the FB3000 and is the answer not in the manual?
Questions and answers