Table of Contents Model PT-TH-0686-HC / Model PT-TH-0920-HC / Model PT-TH-1194-HC Model PT-TH-1524-HC / Model PT-TH-1778-HC Section Page Disclaimer ----------------------------------------------------------------------------------------------------- 3 General Information --------------------------------------------------------------------------------- 4 - 5 Safety and Warranty --------------------------------------------------------------------------------- 5 - 7 Technical Specifications ------------------------------------------------------------------------------- 8 Installation --------------------------------------------------------------------------------------------- 8 - 10...
Disclaimer OMCAN IS NOT RESPONSIBLE FOR ANY DAMAGES DUE TO WATER LEAKS. WARRANTY FOR WATER LEAKS IS VOID IF THE AMBIENT ROOM TEMPERATURE EXCEEDS 75°F AND 55% RELATIVE HUMIDITY, AND THE APPLIANCE DRAIN IS NOT CONNECTED DIRECTLY TO A FLOOR DRAIN.
If the package has suffered rough handling, bumps or damage (visible or concealed), please note it on the bill of lading before accepting the delivery and contact Omcan within 24 hours, so we may initiate a claim with the carrier. A detailed report on the extent of the damage caused to the machine must be filled out within three days, from the delivery date shown in the shipping documents.
Si el paquete ha sufrido un manejo de poco cuidado, golpes o daños (visible o oculto) por favor anote en la factura antes de aceptar la entrega y contacte Omcan dentro de las 24 horas, de modo que podamos iniciar una reclamación con la compañia.
2 YEAR PARTS AND LABOUR 5 YEAR COMPRESSOR WARRANTY Within the warranty period, contact Omcan Inc. at 1-800-465-0234 to schedule an Omcan authorized service technician to repair the equipment locally.
Page 7
Safety and Warranty use. Please see https://omcan.com/disclaimer for complete info. WARNING: The packaging components are classified as normal solid urban waste and can therefore be disposed of without difficulty. In any case, for suitable recycling, we suggest disposing of the products separately (differentiated waste) according to the current norms.
Installation NOTE This product is for indoor use only. It should be placed in a cool and ventilated place without direct sunlight. The normal working environment temperature is in the range of 5℃~35℃. BEST USE ENVIRONMENT • Do not install this product near stoves, grills or other equipment that generates high temperatures. •...
Installation WARNING If the power cord is damaged, in order to avoid danger, it must be replaced by a professional staff who is from the manufacturer’s maintenance department or similar department. • Before using the product, please check whether there is any damage to the main power cord. Do not stress the power cord.
Page 11
Operation 7. Do not use flammable sprays,products or place volatile products near the machine, sparks generated when operating a switch or similar device may cause fire disaster. 8. Do not place any objects at the cooling air outlet and return air inlet, which will affect the interior gas circulation and reduces the cooling effect.
Operation HOW TO SEE THE SET POINT 1. Push and release the SET key, the set point will be showed. 2. Push and immediately release the SET key or wait 5s to return to normal visualization. HOW TO CHANGE THE SET POINT 1.
Maintenance SHUTDOWN 1. Before shutting down, please move the stored food to another refrigerator or freezer. 2. Unplug or disconnect the main power. 3. When the machine is not used for a long time, please clean the inside of the cabinet and the door seals of the cabinet and dry them thoroughly, then wrap the machine with plastic tape and store it in a dry place.
Maintenance AIR FILTER WARNING To prevent deformation of the air filter, please do not use hot water above 40℃ to clean the filter. The plastic filter can remove debris or dust in the air, prevent the condenser from clogging, and affect the refrigeration performance of the freezer to decline.
Page 17
Troubleshooting Fans output enabled. Flashing Fans delay after defrost. Alarms happening. Flashing ------ FAULT WITH SHOWING FAULT CODE When the temperature display window of the thermostat panel flashes the fault code and the temperature in the cabinet alternately, check the fault code and follow the instructions below. Code Failure and remedial measures Cabinet temperature high temperature alarm...
Page 18
Troubleshooting Poor cooling The ambient temperature is too high (above 32℃). performance. Whether the temperature setting is appropriate. Whether put too much food or warm/hot food. The air outlet/return air outlet is blocked. The machine is in the process of defrosting. At this time, the temperature in the cabinet may temporarily increase, but it will not affect the food in the cabinet.
Page 20
Parts Breakdown Model PT-TH-0686-HC 58005 Item No. Description Position Item No. Description Position Item No. Description Position Fan Stainless Steel Mesh Cover Compressor (NUT55NR; AP919 AP933 Top Hinge for 58005 AN293 for 58005 115-127V~60Hz R290) for 58005 Steam Table Pan Cover Sixth...
Page 21
Parts Breakdown Model PT-TH-0920-HC 58006...
Page 22
Parts Breakdown Model PT-TH-0920-HC 58006 Item No. Description Position Item No. Description Position Item No. Description Position Fan Stainless Steel Mesh Cover AP919 AP952 Top Hinge (Left) for 58006 AP940 Condenser Motor for 58006 for 58006 AP920 Evaporator Motor for 58006 AP953 Gasket for 58006 AP957...
Page 23
Parts Breakdown Model PT-TH-1194-HC 58007...
Page 24
Parts Breakdown Model PT-TH-1194-HC 58007 Item No. Description Position Item No. Description Position Item No. Description Position Fan Stainless Steel Mesh Cover AP919 AP952 Top Hinge (Left) for 58007 AP940 Condenser Motor for 58007 for 58007 AP920 Evaporator Motor for 58007 AP963 Gasket for 58007 AP967...
Page 25
Parts Breakdown Model PT-TH-1524-HC 58008...
Page 26
Parts Breakdown Model PT-TH-1524-HC 58008 Item No. Description Position Item No. Description Position Item No. Description Position Fan Stainless Steel Mesh Cover AP919 AP952 Top Hinge (Left) for 58008 AP940 Condenser Motor for 58008 for 58008 AP920 Evaporator Motor for 58008 AP973 Gasket for 58008 AP976...
Page 27
Parts Breakdown Model PT-TH-1778-HC 58009...
Page 28
Parts Breakdown Model PT-TH-1778-HC 58009 Item No. Description Position Item No. Description Position Item No. Description Position Fan Stainless Steel Mesh Cover AP919 AP980 Gasket for 58009 AP942 Power Cable (Black) for 58009 for 58009 Controller (Dixell) 115V/60Hz AP920 Evaporator Motor for 58009 AP933 Top Hinge (Right) for 58009 AP945...
Electrical Schematics Model PT-TH-0686-HC 58005 Model PT-TH-0920-HC 58006 Model PT-TH-1194-HC 58007 Model PT-TH-1524-HC 58008 Model PT-TH-1778-HC 58009...
Warranty Registration Thank you for purchasing an Omcan product. To register your warranty for this product, complete the information below, tear off the card at the perforation and then send to the address specified below. You can also register online by visiting: Merci d’avoir acheté...
Page 32
à plus de 6500 produits provenant du monde entier. Desde 1951 Omcan ha crecido hasta convertirse en un líder en la distribución de equipos y suministros de alimentos en América del Norte industria de servicios. Nuestro éxito en estos años se puede atribuir a nuestro compromiso de fortalecer y desarrollar nuevas relaciones...
Need help?
Do you have a question about the PT-TH-0686-HC and is the answer not in the manual?