Table of Contents Model RE-CN-0006-HC / Model RE-CN-0008-HC / Mode RE-CN-0011-HC Model RE-CN-0015-HC / Model RE-CN-0016-HC / Model RE-CN-0006-BS-HC Model RE-CN-0011-BS-HC / Model RE-CN-0015-BS-HC Model RE-CN-0016-BS-HC / Model FR-CN-0686-HC / Model FR-CN-0008-HC Model FR-CN-1219-HC / Model FR-CN-1524HC / Model FR-CN-0686-BS-HC...
D’huMIDITé relaTIve, eT sI le DraIn De l’appareIl n’esT pas raCCOrDé DIreCTeMenT à un DraIn De planCher. OMCan nO se haCe respOnsable De lOs DañOs CausaDOs pOr Fugas De agua. la garanTía pOr Fugas De agua queDa anulaDa sI la TeMperaTura aMbIenTe supera lOs 75°F y el...
If the package has suffered rough handling, bumps or damage (visible or concealed), please note it on the bill of lading before accepting the delivery and contact Omcan within 24 hours, so we may initiate a claim with the carrier. A detailed report on the extent of the damage caused to the machine must be filled out within three days, from the delivery date shown in the shipping documents.
Si el paquete ha sufrido un manejo de poco cuidado, golpes o daños (visible o oculto) por favor anote en la factura antes de aceptar la entrega y contacte Omcan dentro de las 24 horas, de modo que podamos iniciar una reclamación con la compañia.
Page 6
2 YEARS PARTS AND LABOUR / 5 YEARS PARTS ONLY ON COMPRESSOR WARRANTY Within the warranty period, contact Omcan Inc. at 1-800-465-0234 to schedule an Omcan authorized service technician to repair the equipment locally. Unauthorized maintenance will void the warranty. Warranty covers electrical and part failures, not improper use.
Page 7
safety and Warranty In any case, for suitable recycling, we suggest disposing of the products separately (differentiated waste) according to the current norms. DO NOT DISCARD ANY PACKAGING MATERIALS IN THE ENVIRONMENT!
Technical Specifications WORKTABLE REFRIGERATION Model RE-CN-0006-HC RE-CN-0008-HC RE-CN-0011-HC RE-CN-0015-HC RE-CN-0016-HC Temperature 0.5°C - 5°C / 33°F - 41°F Range Max Ambient 24°C / 75°F Temp Rating Power 124 W 250 W 149 W 324 W 149 W Refrigerant R290 Isolation...
Page 9
Technical Specifications WORKTABLE FREEzERS Model FR-CN-0686-HC FR-CN-0008-HC FR-CN-1219-HC FR-CN-1524-HC Temperature -22 to -18°C / -8 to 0°F Range Max Ambient 24°C / 75°F Temp Rating Power 149 W 275 W 186 W 600 W Refrigerant R290 Isolation Cyclopentane Material Cooling Ventilated System Defrosting...
Page 10
Technical Specifications WORKTABLE REFRIGERATION WITH BACKSPLASH Model RE-CN-0006-BS-HC RE-CN-0011-BS-HC RE-CN-0015-BS-HC RE-CN-0016-BS-HC Volume 154 L / 5 cu.ft. 320 L / 11 cu.ft. 425 L / 15 cu.ft. 481 L / 17 cu.ft. Power 210 W 270 W 345 W 290 W Current 1.8A 2.4A...
Technical Specifications WORKTABLE FREEzERS WITH BACKSPLASH Model FR-CN-0686-BS-HC FR-CN-1219-BS-HC FR-CN-1524-BS-HC Volume 154 L / 5 cu.ft. 320 L / 11 cu.ft. 425 L / 15 cu.ft. Power 480 W 600 W Current 4.2A 5.2A Refrigerant R290 Temperature -22 to -18°C / -8 to 0°F Range Max Ambient 24°C / 75°F...
Page 12
Installation • Make sure that the unit drops down to desired temperature before loading the unit with product. • Make sure that there is proper ventilation around the unit in the area where it will operate. • Make sure all accessories are installed (i.e. shelves, shelf clips, casters) before plugging the unit in. •...
Page 13
Installation LOADING PRODUCT Shelves have been factory-installed for your convenience. Before loading shelves, please be sure that all shelf clips are completely fastened in their correct locations. It is important that all shelves rest completely level before stocking your cabinet with product. In order to maintain correct air flow inside the unit, please be sure to leave two to four(2 to 4) inches of space between the back wall and stored product.
Maintenance CLEANING THE CONDENSER COIL • For efficient operation, it is important that the condenser surface be kept free of dust, dirt, and lint. • We recommend cleaning the condenser coil and fins at least once per month. • Clean with a commercial condenser coil cleaner, available from any kitchen equipment retailer. Brush the condenser fins from top to bottom, not side to side.
Troubleshooting Before requesting any service on your unit, please check the following points. Please note that this guide serve only as a reference for solutions to common problems. SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Compressor not running. Fuse blown or circuit breaker Replace fuse or reset circuit tripped.
Page 16
Troubleshooting Cabinet temperature Is too warm. Thermostat set too warm. Set thermostat to lower temperature. Blocking air flow. Re-arrange product to allow for proper air flow. Make sure there Is at least four inches of clearance from evaporator. Excessive amount of warm product Allow adequate time for product to placed in cabinet.
Controller Instructions Digital controller model: PJEz for cooler Display and functions During normal operation, the controller displays the value of the probe set using parameter/4(=1 ambient probe, default, = 2 second probe, = 3 third probe).In addition, the display has LEDs that indicate the activation of the control functions (see Table 1), while the 3 buttons can be used to activate/deactivate some of the functions(see Table 2).
Page 18
Controller Instructions Table of Functions activated by the buttons - Models S, X, Y, C (Table 2) Button Normal Operation Start Up Pressing the Button Alone Pressed Together More than 3 sec: toggle ON/ Start/Stop ON/OFF continuous cycle Down More than 3 sec: start/stop Pressed For 1 sec.
Page 19
Controller Instructions • to display/set the values of the parameter displayed, press SET, then UP/DOWN and finally SET to confirm the changes (returning to the parameter menu). To save all the new values and exit the parameter menu, press SET for 3 s; To exit the menu without saving the changed values (exit by timeout) do not press any button for at least 60 s.
Page 20
Controller Instructions Light Auxiliary output light Auxiliary output light Anti-sweat heater function active not active active Service No malfunction Malfunction (eg. EEPROM error or probe fault) HACCP HACCP function HACCP function HACCP alarm (HA and/or enabled HF) not enabled Continuous Enabled Not enabled Request...
Page 21
Controller Instructions Accessing the configuration parameter (type F) 1. Hold the “ ” button for more than 5 s (if there are active alarms, first mute the buzzer), the display will show the first modifiable “F” parameter. Modifying the parameters After having displayed the parameter, either type “C”...
parts breakdown Model re-Cn-0006-hC 50054 Model re-Cn-0006-bs-hC 50095...
Page 23
parts breakdown Model re-Cn-0006-hC 50054 Item No. Description Position Item No. Description Position Item No. Description Position AF730 Cabinet for 50054 AB109 Thermostat for 50054 AF741 Evaporator Cover for 50054 AF731 Top Board for 50054 AF080 Stand Off Bracket for 50054 AF090 K Strip-3 Holes for 50054 AF732...
Page 25
Model re-Cn-0008-hC 50102 Item No. Description Position Item No. Description Position Item No. Description Position AN864 Cabinet for 50102 AB320 Thermostat Installation Board for 50102 AN873 Back Grill for 50102 AN865 Top Board for 50102 27185 Carel Controller PYGX1Z0501 for 50102...
Page 26
parts breakdown Model re-Cn-0011-hC 50056 Model re-Cn-0011-bs-hC 50097...
Page 27
parts breakdown Model re-Cn-0011-hC 50056 Item No. Description Position Item No. Description Position Item No. Description Position AF743 Cabinet for 50056 AB320 Thermostat Installation Board for 50056 AF750 Back Grill for 50056 AF744 Top Board for 50056 AB109 Thermostat for 50056 AF751 Evaporator Cover for 50056 AF745...
Page 28
parts breakdown Model re-Cn-0015-hC 50093 Model re-Cn-0015-bs-hC 50099...
Page 29
parts breakdown Model re-Cn-0015-hC 50093 Item No. Description Position Item No. Description Position Item No. Description Position AM740 Cabinet for 50093 AB320 Thermostat Installation Board for 50093 AM712 Compressor Starting Kit for 50093 34 - 37 AN078 Top Board for 50093 AI375 Thermostat for 50093 AM713...
Page 30
parts breakdown Model re-Cn-0016-hC 50091 Model re-Cn-0016-bs-hC 50100...
Page 31
parts breakdown Model re-Cn-0016-hC 50091 Item No. Description Position Item No. Description Position Item No. Description Position Compressor Starting Components for AK189 Cabinet for 50091 AB320 Thermostat Installation Board for 50091 AK194 33-36 50091 AK190 Top Board for 50091 AI375 Thermostat for 50091 AK195 Back Grill for 50091...
Page 32
parts breakdown Model Fr-Cn-0686-hC 50053 Model Fr-Cn-0686-bs-hC 50094...
Page 33
parts breakdown Model Fr-Cn-0686-hC 50053 Item No. Description Position Item No. Description Position Item No. Description Position AF730 Cabinet for 50053 AF080 Stand Off Bracket for 50053 AF089 K Strip-2 Holes for 50053 AF731 Top Board for 50053 AF085 Compressor Unit Track for 50053 26884 K Clip for 50053 AB172...
Page 34
parts breakdown Model Fr-Cn-0008-hC 50103...
Page 35
parts breakdown Model Fr-Cn-0008-hC 50103 Item No. Description Position Item No. Description Position Item No. Description Position AN864 Cabinet for 50103 AI322 Thermostat for 50103 AF090 K Strip-3 Holes for 50103 AN865 Top Board for 50103 AF080 Stand Off Bracket for 50103 AF089 K Strip-2 Holes for 50103 AN880...
Page 36
parts breakdown Model Fr-Cn-1219-hC 50055 Model Fr-Cn-1219-bs-hC 50096...
Page 37
parts breakdown Model Fr-Cn-1219-hC 50055 Item No. Description Position Item No. Description Position Item No. Description Position AF743 Cabinet for 50055 AA324 Thermostat for 50055 AF090 K Strip-3 Holes for 50055 AF744 Top Board for 50055 AF080 Stand Off Bracket for 50055 AF089 K Strip-2 Holes for 50055 AF755...
Page 38
parts breakdown Model Fr-Cn-1524-hC 50092 Model Fr-Cn-1524-bs-hC 50098...
Page 39
parts breakdown Model Fr-Cn-1524-hC 50092 Item No. Description Position Item No. Description Position Item No. Description Position AM717 Cabinet for 50092 AI322 Thermostat for 50092 AM723 Evaporator Cover for 50092 AN078 Top Board for 50092 AF080 Stand Off Bracket for 50092 AF090 K Strip-3 Holes for 50092 AM718...
Warranty registration Thank you for purchasing an Omcan product. To register your warranty for this product, complete the information below, tear off the card at the perforation and then send to the address specified below. You can also register online by visiting: Merci d’avoir acheté...
Page 52
Since 1951 Omcan has grown to become a leading distributor of equipment and supplies to the North American food service industry. Our success over these many years can be attributed to our commitment to strengthen and develop new and existing relationships with our valued customers and manufacturers.
Need help?
Do you have a question about the RE-CN-0008-HC and is the answer not in the manual?