Omcan Aurora PT-CN-0686E-HC Instruction Manual

Refrigerated prep unit
Hide thumbs Also See for Aurora PT-CN-0686E-HC:

Advertisement

Quick Links

Aurora Refrigerated Prep Units
Models PT-CN-0686E-HC, 1194E-HC, 0711E-HC, 1537E-HC,
1270E-HC, 1829E-HC
Items 59045, 59046, 59049, 59051, 59042, 59043
Instruction Manual
Revised - 11/30/2022
Toll Free: 1-800-465-0234
Fax: 905-607-0234
Email: service@omcan.com
www.omcan.com

Advertisement

Table of Contents
loading

Summary of Contents for Omcan Aurora PT-CN-0686E-HC

  • Page 1 Aurora Refrigerated Prep Units Models PT-CN-0686E-HC, 1194E-HC, 0711E-HC, 1537E-HC, 1270E-HC, 1829E-HC Items 59045, 59046, 59049, 59051, 59042, 59043 Instruction Manual Revised - 11/30/2022 Toll Free: 1-800-465-0234 Fax: 905-607-0234 Email: service@omcan.com www.omcan.com...
  • Page 2: Table Of Contents

    Table of Contents Model PT-CN-0686E-HC / Model PT-CN-1194E-HC / Model PT-CN-0711E-HC Model PT-CN-1537E-HC / Model PT-CN-1270E-HC / Model PT-CN-1829E-H Section Page Disclaimer -------------------------------------------------------------------------------------------- 3 General Information --------------------------------------------------------------------------- 4 - 5 Safety and Warranty --------------------------------------------------------------------------- 5 - 7 Technical Specifications ---------------------------------------------------------------------- 7 - 9 Installation -------------------------------------------------------------------------------------- 9 - 11 Maintenance...
  • Page 3: Disclaimer

    Disclaimer OMCAN IS NOT RESPONSIBLE FOR ANY DAMAGES DUE TO WATER LEAKS. WARRANTY FOR WATER LEAKS IS VOID IF THE AMBIENT ROOM TEMPERATURE EXCEEDS 75°F AND 55% RELATIVE HUMIDITY, AND THE APPLIANCE DRAIN IS NOT CONNECTED DIRECTLY TO A FLOOR DRAIN.
  • Page 4: General Information

    If the package has suffered rough handling, bumps or damage (visible or concealed), please note it on the bill of lading before accepting the delivery and contact Omcan within 24 hours, so we may initiate a claim with the carrier. A detailed report on the extent of the damage caused to the machine must be filled out within three days, from the delivery date shown in the shipping documents.
  • Page 5: Safety And Warranty

    Si el paquete ha sufrido un manejo de poco cuidado, golpes o daños (visible o oculto) por favor anote en la factura antes de aceptar la entrega y contacte Omcan dentro de las 24 horas, de modo que podamos iniciar una reclamación con la compañia.
  • Page 6 2 YEARS PARTS AND LABOUR / 5 YEARS PARTS ONLY ON COMPRESSOR WARRANTY Within the warranty period, contact Omcan Inc. at 1-800-465-0234 to schedule an Omcan authorized service technician to repair the equipment locally. Unauthorized maintenance will void the warranty. Warranty covers electrical and part failures, not improper use.
  • Page 7: Technical Specifications

    Safety and Warranty In any case, for suitable recycling, we suggest disposing of the products separately (differentiated waste) according to the current norms. DO NOT DISCARD ANY PACKAGING MATERIALS IN THE ENVIRONMENT! Technical Specifications REFRIGERATED PREP TABLES Model PT-CN-0686E-HC PT-CN-1194E-HC Net Volume 201 L / 7.1 cu.ft.
  • Page 8 Technical Specifications MEGA REFRIGERATED PREP TABLES Model PT-CN-0711E-HC PT-CN-1537E-HC Net Volume 201 L / 7.1 cu.ft. 469 L / 16.6 cu.ft. Temperature Range 0.5 - 4.4°C / 33 - 40°F Max Ambient Temp 24°C / 75°F Rating Refrigerant R290 Electrical 110V / 60Hz / 1 Power 0.5 HP / 372 W...
  • Page 9: Installation

    Technical Specifications PIZZA REFRIGERATED PREP TABLES Model PT-CN-1270E-HC PT-CN-1829E-HC Net Volume 220 L / 7.8 cu.ft. 442 L / 15.6 cu.ft. Temperature Range 0.5 - 4.4°C / 33°F - 40°F Max Ambient Temp 24°C / 75°F Rating Refrigerant R290 Electrical 110V / 60Hz / 1 Power 0.5 HP / 336 W...
  • Page 10 Installation CABINET LOCATION GUIDELINES • Install the unit on strong and leveled surfaces. - Unit may make unpleasant noises if surface is uneven. - Unit may malfunction if surface is uneven. • Install the unit in an indoor, well-ventilated area. - Unit performs more efficiently in a well-ventilated area.
  • Page 11: Maintenance

    Installation DEFROST SYSTEMS Refrigerator coils are kept below the freezing point (32°F). During compressor down-time, the evaporator fan continues to circulate air through the evaporator coil. This air circulation raises the coil temperature above the freezing point, melting any accumulated frost. Run-off water is drained into the evaporator pan and evaporated. Freezer coils are defrosted electrically.
  • Page 12: Troubleshooting

    Maintenance CLEANING THE FAN BLADE AND MOTOR • If necessary, clean the fan blades and motor with a soft cloth, If it is necessary to wash the fan blades, cover the fan motor to prevent moisture damage. CLEANING THE INTERIOR OF UNIT •...
  • Page 13 Troubleshooting Condensing unit runs for long Excessive amount of warm product Allow adequate time for Product to periods of time. Placed in cabinet. cool down. Prolonged door opening or door Ensure doors are closed when not ajar. in use. Avoid opening doors for long periods of time.
  • Page 14: Controller Instructions

    Controller Instructions Digital controller model: PJEZ for cooler Display and functions During normal operation, the controller displays the value of the probe set using parameter/4 (=1 ambient probe, default, = 2 second probe, = 3 third probe).In addition, the display has LEDs that indicate the activation of the control functions (see Table 1), while the 3 buttons can be used to activate/deactivate some of the functions (see Table 2).
  • Page 15 Controller Instructions Table of Functions activated by the buttons - Models S, X, Y, C (Table 2) Button Normal Operation Start Up Pressing the Button Alone Pressed Together More than 3 sec: toggle ON/ Start/Stop ON/OFF continuous cycle Down More than 3 sec: start/stop Pressed For 1 sec.
  • Page 16 Controller Instructions • to display/set the values of the parameter displayed, press SET, then UP/DOWN and finally SET to confirm the changes (returning to the parameter menu). To save all the new values and exit the parameter menu, press SET for 3 s; To exit the menu without saving the changed values (exit by timeout) do not press any button for at least 60 s.
  • Page 17: Parts Breakdown

    Parts Breakdown Model PT-CN-0686E-HC 59045...
  • Page 18 Parts Breakdown Model PT-CN-0686E-HC 59045 Item No. Description Position Item No. Description Position Item No. Description Position AF068 Cabinet for 59045 AL925 Right Clapboard of Evaporator for 59045 AB595 Filter Fixer for 59045 AL920 Door for 59045 AL926 Left Clapboard of Evaporator for 59045 AI968 Filter for 59045 AB250...
  • Page 19 Parts Breakdown Model PT-CN-1194E-HC 59046...
  • Page 20 Parts Breakdown Model PT-CN-1194E-HC 59046 Item No. Description Position Item No. Description Position Item No. Description Position AF092 Cabinet for 59046 AF100 Inner Drain Pan for 59046 AL932 Condenser Fan Motor for 59046 AL940 Right Door for 59046 AL945 Evaporator for 59046 AI391 Blade of Condenser Fan Motor for 59046 AB197...
  • Page 21 Parts Breakdown Model PT-CN-0711E-HC 59049...
  • Page 22 Parts Breakdown Model PT-CN-0711E-HC 59049 Item No. Description Position Item No. Description Position Item No. Description Position AF068 Cabinet for 59049 AL925 Right Clapboard of Evaporator for 59049 AB595 Filter Fixer for 59049 AL920 Door for 59049 AL926 Left Clapboard of Evaporator for 59049 AI968 Filter for 59049 AB250...
  • Page 23 Parts Breakdown Model PT-CN-1537E-HC 59051...
  • Page 24 Parts Breakdown Model PT-CN-1537E-HC 59051 Item No. Description Position Item No. Description Position Item No. Description Position AF108 Cabinet for 59051 AF116 Inner Drain Pan for 59051 AL932 Condenser Fan Motor for 59051 AL955 Right Door for 59051 AI371 Evaporator for 59051 AI391 Blade of Condenser Fan Motor for 59051 AB363...
  • Page 25 Parts Breakdown Model PT-CN-1270E-HC 59042...
  • Page 26 Parts Breakdown Model PT-CN-1270E-HC 59042 Item No. Description Position Item No. Description Position Item No. Description Position AL962 Cabinet for 59042 AB475 Lid Hinge Axis for 59042 AL985 Right Compressor Unit Track for 59042 Compressor Unit Installation Board AL963 Top Rail for 59042 AL973 Evaporator for 59042 AL986...
  • Page 27 Parts Breakdown Model PT-CN-1829E-HC 59043...
  • Page 28 Parts Breakdown Model PT-CN-1829E-HC 59043 Item No. Description Position Item No. Description Position Item No. Description Position AL989 Cabinet for 59043 AL994 Lid for 59043 AL985 Right Compressor Unit Track for 59043 Compressor Unit Installation Board AL990 Top Rail for 59043 AB475 Lid Hinge Axis for 59043 AL986...
  • Page 29: Electrical Schematics

    Electrical Schematics Model PT-CN-0686E-HC 59045...
  • Page 30 Electrical Schematics Model PT-CN-1194E-HC 59046...
  • Page 31 Electrical Schematics Model PT-CN-0711E-HC 59049...
  • Page 32 Electrical Schematics Model PT-CN-1537E-HC 59051...
  • Page 33 Electrical Schematics Model PT-CN-1270E-HC 59042...
  • Page 34 Electrical Schematics Model PT-CN-1829E-HC 59043...
  • Page 35: Warranty Registration

    Warranty Registration Thank you for purchasing an Omcan product. To register your warranty for this product, complete the information below, tear off the card at the perforation and then send to the address specified below. You can also register online by visiting: Merci d’avoir acheté...
  • Page 36 Since 1951 Omcan has grown to become a leading distributor of equipment and supplies to the North American food service industry. Our success over these many years can be attributed to our commitment to strengthen and develop new and existing relationships with our valued customers and manufacturers.

Table of Contents