Crestron C2N-MNETGW Operation Manual
Crestron C2N-MNETGW Operation Manual

Crestron C2N-MNETGW Operation Manual

Infinet gateway/transceiver
Hide thumbs Also See for C2N-MNETGW:

Advertisement

Quick Links

Crestron C2N-MNETGW
infiNET™ Gateway/Transceiver
Operations Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C2N-MNETGW and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Crestron C2N-MNETGW

  • Page 1 Crestron C2N-MNETGW infiNET™ Gateway/Transceiver Operations Guide...
  • Page 2 This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2005 Crestron Electronics, Inc.
  • Page 3: Table Of Contents

    Crestron C2N-MNETGW infiNET™ Gateway/Transceiver Contents infiNET™ Two-Way RF Transceiver: C2N-MNETGW Introduction..................1 Functions and Features ............1 InfiNET Technology..............2 Specifications.................3 Physical Description ..............4 Industry Compliance..............7 Setup....................8 Network Wiring ..............8 Crestron Toolbox ..............9 Identity Code ...............10 Configuring the infiNET Network ........12 Hardware Hookup..............20 Programming Software ..............21...
  • Page 5: Infinetâ„¢ Two-Way Rf Transceiver: C2N-Mnetgw

    Crestron C2N-MNETGW infiNET™ Gateway/Transceiver infiNET™ Two-Way RF Transceiver: C2N-MNETGW Introduction Functions and Features The C2N-MNETGW is a two-way radio frequency (RF) gateway/transceiver that utilizes the 2.4 GHz “ISM band” to ® communicate with the Crestron infiNET line of wireless network devices.
  • Page 6: Infinet Technology

    C2N-MNETGW devices may be added to a Cresnet network. InfiNET Technology The C2N-MNETGW is a part of Crestron’s line of network devices using infiNET network technology. InfiNET technology is “Wi-Fi” friendly and provides fault tolerance and increased reliability as network devices are added.
  • Page 7: Specifications

    Multiple gateways can be connected via Cresnet to one 2-Series control system. Specifications The table below is a summary of specifications for the C2N-MNETGW. Specifications of the C2N-MNETGW SPECIFICATION DETAILS Cresnet Power Usage 3 Watts (24VDC @ 0.125A)
  • Page 8: Physical Description

    RF interference, multiple transceivers operating at the same frequencies should not be installed within three to five feet of each other. The latest software versions can be obtained from the Crestron website. Refer to the NOTE following these footnotes.
  • Page 9 Physical Views of C2N-MNETGW Ports The C2N-MNETGW has two ports. Refer to the diagrams and descriptions that follow. This 4-position terminal block connector is used to connect the C2N-MNETGW to the Cresnet network.
  • Page 10 The C2N-MNETGW indicators are described in the following paragraphs. PWR (Power) This LED illuminates when 24 VDC is supplied to the C2N-MNETGW via the NET port. This LED illuminates when communication between the control system and the C2N-MNETGW (over Cresnet) is established (the unit is polled on the network).
  • Page 11: Industry Compliance

    Crestron C2N-MNETGW infiNET™ Gateway/Transceiver Industry Compliance As of the date of manufacture, the C2N-MNETGW has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling. Contains FCC ID: EROCWD1012 NOTE: This device complies with part 15 of the FCC rules. Operation is...
  • Page 12: Setup

    CAUTION: Use only Crestron power supplies for Crestron equipment. Failure to do so could cause equipment damage or void the Crestron warranty. CAUTION: Provide sufficient power to the system. Insufficient power can lead to unpredictable results or damage to the equipment.
  • Page 13: Crestron Toolbox

    NOTE: The minimum version of Crestron Toolbox required to operate with the C2N-MNETGW is version 1.02.06 or later. The Crestron Toolbox (a replacement for Crestron Viewport) is a broad- based software package that accomplishes multiple system tasks, primarily using an RS-232 or TCP/IP connection between a PC and one or more Crestron control systems.
  • Page 14: Identity Code

    Net ID in Device Settings” on page 25 for details of the SIMPL Windows procedure. The Net ID of the C2N-MNETGW has been factory set to 0F. The Net IDs of multiple C2N-MNETGW devices in the same system must be unique.
  • Page 15 4. Expand the Network Device Tree until the Net ID that is to be changed is visible. Right-click on the Net ID, and when the sub- menu appears, select Change Network ID. “Network Device Tree” – Sub-Menu Operations Guide - DOC. 6317 infiNET™ Gateway/Transceiver: C2N-MNETGW • 11...
  • Page 16: Configuring The Infinet Network

    Acquire mode. Refer to “Acquiring Devices” on page 15 for information. Setting the Operating Channel The C2N-MNETGW can operate on a fixed channel that is set by the installer or it can automatically set itself to the clearest channel. 12 • infiNET™ Gateway/Transceiver: C2N-MNETGW...
  • Page 17 For systems using multiple gateways or systems operating in environments containing other devices that use similar frequencies, Crestron recommends setting the C2N-MNETGW to operate on a fixed channel to avoid RF interference with other devices in the vicinity. Ideally, each gateway should operate on its own channel to avoid interfering with other gateways operating in the vicinity.
  • Page 18 The gateway will scan for a new channel if it detects a specific level of interference. • Fixed: The C2N-MNETGW is set to the channel specified from the adjacent dropdown list. NOTE: Changes to the channel and channel selection mode are applied immediately.
  • Page 19 (even if the gateway and the device are operating on the same channel). To add infiNET devices to the network, the C2N-MNETGW must be in the Acquire mode. The Acquire mode can be activated from Crestron Toolbox (recommended) or the device. The Acquire mode can be activated approximately 15 seconds after applying power to the C2N-MNETGW.
  • Page 20 InfiNET™ Gateway/Transceiver Crestron C2N-MNETGW NOTE: If the C2N-MNETGW is already in the Acquire mode, a message indicating the status will be displayed. Acquire Mode Message 2. To place the C2N-MNETGW in the Acquire mode, click Start Acquire. The default time that the C2N-MNETGW remains in the Acquire mode (when starting the Acquire mode from Toolbox) is one hour.
  • Page 21 NOTE: If the acquired devices have never had an MNET ID assigned, they will be acquired with the default MNET ID 01. Just like a device on a Cresnet system (like the C2N-MNETGW) requires a unique identity code (NET ID), every device and user interface on the infiNET network requires a unique identity code (MNET ID) that identifies it to a control system.
  • Page 22 InfiNET™ Gateway/Transceiver Crestron C2N-MNETGW NOTE: The C2N-MNETGW must be placed in the Acquire mode before an infiNET device is placed in the Acquire mode. 2. Place new infiNET devices in the Acquire mode as described in their respective manuals. Devices will be automatically acquired by the gateway approximately five minutes after they enter the Acquire mode.
  • Page 23 Reacquire the device if desired. Devices can also be released from a gateway at the device. Refer to the infiNET device’s Operations Guide. Operations Guide - DOC. 6317 infiNET™ Gateway/Transceiver: C2N-MNETGW • 19...
  • Page 24: Hardware Hookup

    InfiNET™ Gateway/Transceiver Crestron C2N-MNETGW Hardware Hookup The C2N-MNETGW serves as a gateway between infiNET devices and the Cresnet system. Refer to the illustration after this paragraph for proper connections; apply power last. When making network connections to a control system or Cresnet peripherals, refer to “Network Wiring” on page 8.
  • Page 25: Programming Software

    Have a question or comment about Crestron software? Answers to frequently asked questions (FAQs) can be viewed in the Online Help section of the Crestron website. To post your own question or view questions you have submitted to Crestron’s True Blue Support, log in at http://support.crestron.com.
  • Page 26: Earliest Version Software Requirements For The Pc

    InfiNET™ Gateway/Transceiver Crestron C2N-MNETGW Earliest Version Software Requirements for the NOTE: Crestron recommends that you use the latest software to take advantage of the most recently released features. The latest software is available from the Crestron website. The following are the minimum recommended software versions for the PC running Windows XP or Windows 2000: •...
  • Page 27: Programming With Simpl Windows

    The C2N-MNETGW does not require any specific programming other than placing it in the SIMPL Windows program. A program can be created that includes a C2N-MNETGW and infiNET devices using the Crestron programming tool SIMPL Windows. NOTE: The following assumes that the reader has knowledge of SIMPL Windows.
  • Page 28 Wireless Receivers | Wireless Receivers (RF) folder of the Device Library and drop it in the System Views. The PAC2 system tree displays the C2N-MNETGW in slot 6 with a default Net ID of 0F as shown in the following illustration.
  • Page 29 Crestron C2N-MNETGW infiNET™ Gateway/Transceiver NOTE: The first C2N-MNETGW in a system is preset with a Net ID of 0F when its symbol is dragged into the upper pane of System Views. Additional units are assigned different Net ID numbers as they are added.
  • Page 30 InfiNET™ Gateway/Transceiver Crestron C2N-MNETGW Adding infiNET Devices to the C2N-MNETGW To add infiNET devices to the C2N-MNETGW, right click on the C2N-MNETGW, select Add item to: “C2N-MNETGW” and select an infiNET device as shown in the following diagram. Adding an infiNET Device to the C2N-MNETGW The selected infiNET device will be added with a default MNET ID.
  • Page 31: Uploading And Upgrading

    Establishing Communications The procedure in this section provides details for RS-232 communication between a PC and the C2N-MNETGW via the control system. This method can be used to communicate with the control system directly and with a C2N-MNETGW via the control system’s Cresnet connection. If TCP/IP communication is preferred, consult the latest version of the Crestron e-Control Reference Guide (Doc.
  • Page 32 InfiNET™ Gateway/Transceiver Crestron C2N-MNETGW connection diagram when connecting to a C2N-MNETGW via a control system. Indirect Serial Communications Setup Connections 1. Ensure that all devices are connected to the control system and the control system is connected via serial cable to the PC.
  • Page 33 Serial on COM1 from the drop down list if it is not already selected. If communication is successful, the network devices that are connected to the control system are displayed. Network Device Tree Operations Guide - DOC. 6317 infiNET™ Gateway/Transceiver: C2N-MNETGW • 29...
  • Page 34: Troubleshooting Communications

    Use the following checklist if communication cannot be established with the control system. 1. Verify that the correct cables are used. Refer to the control systems Operations Guide for information about RS-232 cables. 30 • infiNET™ Gateway/Transceiver: C2N-MNETGW Operations Guide - DOC. 6317...
  • Page 35: Uploading A Simpl Windows Program

    27 has been performed to establish a connection between the PC and the control system. 2. Open Crestron Toolbox and select Tools | System Info. Crestron Toolbox – Tools | System Info Operations Guide - DOC. 6317 infiNET™ Gateway/Transceiver: C2N-MNETGW • 31...
  • Page 36 “SIMPL Program” Window 5. Click the button to browse for a new compiled (.spz) program. “Open” Window 6. Select a file and click Open. When the “SIMPL Program” window re-opens click Send. 32 • infiNET™ Gateway/Transceiver: C2N-MNETGW Operations Guide - DOC. 6317...
  • Page 37: Firmware Upgrade

    1. Verify that the procedure for “Establishing Communications” that begins on page 27 has been performed. 2. Open Crestron Toolbox and open the Network Device Tree (the firmware upgrade function is also available in the SMW Program Tree window).
  • Page 38 7. The “Firmware” window reopens indicating the new firmware version to be uploaded. Click Send to transfer the new firmware to the device. Click Close after the firmware has been transferred. 34 • infiNET™ Gateway/Transceiver: C2N-MNETGW Operations Guide - DOC. 6317...
  • Page 39: Problem Solving

    Functions | MNET Gateway…. If devices are not listed, add devices by putting the C2N-MNETGW and infiNET device in Acquire mode. (continued on following page) Operations Guide - DOC. 6317 infiNET™ Gateway/Transceiver: C2N-MNETGW • 35...
  • Page 40 ACQUIRE. Intermittent C2N-MNETGW Verify that large amount of response from is in vicinity of metal is not in vicinity of metal C2N-MNETGW transmission. during obstruction. communication with infiNET devices. 36 • infiNET™ Gateway/Transceiver: C2N-MNETGW Operations Guide - DOC. 6317...
  • Page 41: Further Inquiries

    Crestron website (www.crestron.com) for a listing of Crestron worldwide offices. You can also log onto the online help section of the Crestron website to ask questions about Crestron products. First-time users will need to establish a user account to fully benefit from all available features.
  • Page 42: Appendix A: The Infinet Spectrum

    Wi-Fi (802.11b) To manage interference that may be present at installation time or may be introduced later, the C2N-MNETGW has the ability to automatically select a channel to operate on based on an evaluation of RF signal levels on each channel. The gateway and devices are therefore designed to be able to track and, if necessary, re-locate to channels with less interference.
  • Page 43: Appendix B: Optimum Rf Reception Guidelines

    (no obstructions between gateway, repeaters, and other infiNET devices). Crestron recommends that the gateway be placed at least five to six feet high for best results. Avoid placing gateways at a low height or on the ground.
  • Page 44: Antenna Orientation

    Antenna Orientation The antenna orientation on the C2N-MNETGW can have considerable effect on the signal range and reliability. In most applications, the antenna should be set vertically as shown in the following diagrams.
  • Page 45 (perpendicular to the metal surface) as shown in the following diagram. Horizontal Orientation NOTE: RF propagation is best from the sides of the antenna. For specific information on where to place the C2N-MNETGW, refer to “Gateway Placement” on page 39. Operations Guide - DOC. 6317 infiNET™ Gateway/Transceiver: C2N-MNETGW • 41...
  • Page 46: Return And Warranty Policies

    (property or economic damages inclusive) arising from the sale or use of this equipment. CRESTRON is not liable for any claim made by a third party or made by the purchaser for a third party.
  • Page 47 Crestron C2N-MNETGW infiNET™ Gateway/Transceiver This page intentionally left blank. Operations Guide - DOC. 6317 infiNET™ Gateway/Transceiver: C2N-MNETGW • 43...
  • Page 48 Crestron Electronics, Inc. Operations Guide - DOC. 6317 15 Volvo Drive Rockleigh, NJ 07647 (2011634) Tel: 888.CRESTRON 12.05 Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice.

Table of Contents