Installation and Operation Manual
X-VA-1350G-eng
Part Number: 541B205AAG
November, 2016
®
Brooks
Sho-Rate™ Series
Models 1350G/1355G Sizes 2-6
Sho-Rate
Model 1350G
(No Valve)
Sho-Rate
Model 1355G
(No Valve)
Brooks
®
Sho-Rate
Sho-Rate
Model 1350G
with optional
integrated
flow controller
Sho-Rate
Model 1355G
with optional
integrated
flow controller
TM
Models 1350G/1355G
Sho-Rate
Model 1350G
with optional
needle valve
Sho-Rate
Model 1355G
with optional
needle valve

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sho-Rate 1350G and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Brooks Sho-Rate 1350G

  • Page 1 Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG Brooks ® Sho-Rate Models 1350G/1355G November, 2016 ® Brooks Sho-Rate™ Series Models 1350G/1355G Sizes 2-6 Sho-Rate Sho-Rate Sho-Rate Model 1350G Model 1350G Model 1350G (No Valve) with optional with optional integrated needle valve...
  • Page 2 Read before proceeding! Brooks Instrument designs, manufactures and tests its products to meet many national and international standards. These products must be properly installed, operated and maintained to ensure they continue to operate within their normal specifications. The following instructions must be adhered to and integrated into your safety program when installing, operating and maintaining Brooks Instrument products.
  • Page 3 We appreciate this opportunity to service your flow measurement and control requirements with a Brooks Instrument device. Every day, flow customers all over the world turn to Brooks Instrument for solutions to their gas and liquid low-flow applications. Brooks provides an array of flow measurement and control products for various industries from biopharmaceuticals, oil and gas, fuel cell research and chemicals, to medical devices, analytical instrumentation, semiconductor manufacturing, and more.
  • Page 4 Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG ® Brooks Sho-Rate Models 1350G/1355G November, 2016 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
  • Page 5: Table Of Contents

    Figures Typical Flowmeter Installation ........................2-3 Dimensions - Sho-Rate 1350G ........................2-3 Dimensions - Sho-Rate 1350G Panel Mount ..................... 2-4 Dimensions - Sho-Rate 1350G Bezel ......................2-4 Dimensions - Sho-Rate 1355G ........................2-5 Dimensions - Sho-Rate 1355G Panel Mount ..................... 2-6 Dimensions - Sho-Rate 1355G Bezel ......................
  • Page 6 Contents Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG Brooks ® Sho-Rate Models 1350G/1355G November, 2016 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
  • Page 7: Section 1 Introduction

    Section 1 Introduction Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG ® Brooks Sho-Rate Models 1350G/1355G November, 2016 1-1 Description The Sho-Rate Flowmeters are variable area, glass tube, flow rate indicating meters. The basic elements are a tapered glass metering tube and a metering float.
  • Page 8: Specifications For Sho-Rate Models 1350G And 1355G

    Section 1 Introduction Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG Brooks ® Sho-Rate Models 1350G/1355G November, 2016 Table 1-1 Specifications for Sho-Rate Models 1350G and 1355G 1350G 1350G 1350G 1350G 1350G 1355G 1355G 1355G 1355G 1355G Performance Performance Performance...
  • Page 9: Tube And Float Code - Eighth And Ninth Digit In Model Code For Scale Configuration

    Section 1 Introduction Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG ® Brooks Sho-Rate Models 1350G/1355G November, 2016 Table 1-2 Capacities - Rib Guide Tubes, Spherical Floats for use with 1350G Series Only Meter Meter Meter T T T T T ube...
  • Page 10: Optional Equipment

    For more details on the needle valve go to our website: BrooksInstrument.com, select Documentation, Precision Valves & Flow Controllers, select Brooks-Line IV, CART, 8503 or 8504 valves. Flow Contollers Flow controllers can be supplied integrally mounted to the inlet or outlet of the instrument.
  • Page 11: Section 2 Installation

    2-5 Recommended Storage Practice If intermediate or long term storage is required for equipment, as supplied by Brooks Instrument, it is recommended that said equipment be stored in accordance with the following: • Within the original shipping container.
  • Page 12: Installation

    Section 2 Installation Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG ® Brooks Sho-Rate Models 1350G/1355G November, 2016 • Stored in a sheltered area, preferably a warm, dry heated warehouse. • Ambient temperature: 70°F (21.0°C) nominal, 110°F (43°C) maximum, 45°F (7.1°C ) minimum.
  • Page 13: Typical Flowmeter Installation

    Figure 2-1 Typical Flowmeter Installation It is recommended that a final leak test of the system plumbing and meter be performed before subjecting it to process fluid. (See "4-2 Reassembly Procedure" on p. 4-2, step 6) Figure 2-2 Dimensions - Sho-Rate 1350G...
  • Page 14: Dimensions - Sho-Rate 1350G Panel Mount

    Section 2 Installation Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG ® Brooks Sho-Rate Models 1350G/1355G November, 2016 Figure 2-3 Dimensions - Sho-Rate 1350G Panel Mount Figure 2-4 Dimensions - Sho-Rate 1350G Bezel...
  • Page 15: Dimensions - Sho-Rate 1355G

    Section 2 Installation Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG ® Brooks Sho-Rate Models 1350G/1355G November, 2016 Figure 2-5 Dimensions - Sho-Rate 1355G...
  • Page 16: Dimensions - Sho-Rate 1355G Panel Mount

    Section 2 Installation Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG ® Brooks Sho-Rate Models 1350G/1355G November, 2016 Figure 2-6 Dimensions - Sho-Rate 1355G Panel Mount...
  • Page 17: Dimensions - Sho-Rate 1355G Bezel

    Section 2 Installation Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG ® Brooks Sho-Rate Models 1350G/1355G November, 2016 Figure 2-7 Dimensions - Sho-Rate 1355G Bezel...
  • Page 18: Dimensions - Model 1350G/1355G With Flow Controller

    Section 2 Installation Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG ® Brooks Sho-Rate Models 1350G/1355G November, 2016 Figure 2-8 Dimensions - Model 1350G/1355G with Flow Controller...
  • Page 19: Section 3 Operation

    Section 3 Operation Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG Brooks ® Sho-Rate Models 1350G/1355G November, 2016 3-1 Operation After the flowmeter has been installed in the flow system, it is ready for operation. An optional built-in needle control valve may be provided to control the flow through the flowmeter.
  • Page 20 Section 3 Operation Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG ® Brooks Sho-Rate Models 1350G/1355G November, 2016 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
  • Page 21: Section 4 Maintenance

    Section 4 Maintenance Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG Brooks ® Sho-Rate Models 1350G/1355G November, 2016 4-1 Disassembly and Cleaning It is recommended the user periodically inspect the tube and float, and clean if necessary. Dirt or foreign materials adhering to the tube and float may cause inaccuracy and sticking of the float.
  • Page 22: Reassembly Procedure

    Section 4 Maintenance Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG ® Brooks Sho-Rate Models 1350G/1355G November, 2016 4-2 Reassembly Procedure 1. Use the reverse of Steps 1 through 5 of the disassembly procedure to reassemble the meter. 2. Prior to installing the needle control valve assembly make certain that the valve stem is turned completely counterclockwise (full open position) to prevent damage to the valve seat.
  • Page 23: Section 5 Parts List

    Section 5 Parts List Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG Brooks ® Sho-Rate Models 1350G/1355G November, 2016 5-1 General When ordering parts please specify: Brooks Serial Number Model Number Part Number Description and Quantity (Refer to Figure 5-1 and Table 5-1)
  • Page 24: Parts Drawing Sho-Rate Models 1350G And 1355G

    Section 5 Parts List Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG ® Brooks Sho-Rate Models 1350G/1355G November, 2016 Figure 5-1 Parts Drawing Sho-Rate Models 1350G and 1355G...
  • Page 25 Section 5 Parts List Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG Brooks ® Sho-Rate Models 1350G/1355G November, 2016 Table 5-1 Sho-Rate 1350G/1355G Parts List COMPONENT PART NUMBER for PART DESCRIPTION QTY. 1350G 1355G SEAL END FITTING Brass 325A110GGJ 325A110GGJ...
  • Page 26 X-VA-1350G-eng Part Number: 541B205AAG ® Brooks Sho-Rate Models 1350G/1355G November, 2016 Table 5-1 Sho-Rate 1350G/1355G Parts List (Continued) COMPONENT PART NUMBER for PART DESCRIPTION QTY. 1350G 1355G ADAPTERS from End Fitting ( to 5/16-24 UNF ) **2 if no FCA, 1 if with FCA 2 or 1...
  • Page 27 Section 5 Parts List Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG Brooks ® Sho-Rate Models 1350G/1355G November, 2016 Table 5-1 Sho-Rate 1350G/1355G Parts List (Continued) COMPONENT PART NUMBER for PART DESCRIPTION QTY. 1350G 1355G 20 INLET FLOAT STOP R-2-65-AG,BG,CG Std Teflon...
  • Page 28 Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG ® Brooks Sho-Rate Models 1350G/1355G November, 2016 Table 5-1 Sho-Rate 1350G/1355G Parts List (Continued) COMPONENT PART NUMBER for PART DESCRIPTION QTY. 1350G 1355G ADAPTER: Flow Controller to Cust Connection (1/4" M-NPT to) 1/8" (F) NPT...
  • Page 29 Section 5 Parts List Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG Brooks ® Sho-Rate Models 1350G/1355G November, 2016 Table 5-1 Sho-Rate 1350G/1355G Parts List (Continued) O-RING MATERIAL VALVE TYPE SIZE BUNA VITON KALREZ EPR/EPM KALREZ/TEFLON BUTYL 947N091BMA 947N092BMA 947N095BMA...
  • Page 30 Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG ® Brooks Sho-Rate Models 1350G/1355G November, 2016 Table 5-1 Sho-Rate 1350G/1355G Parts List (Continued) Sho-Rate G Valve Sizing - AIR Sho-Rate G Valve Sizing - WATER Recommended Recommended Recommended Recommended Max Flow (SCCM...
  • Page 31: Section A Essential Instructions

    Section A Essential Instructions Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG Brooks ® Sho-Rate Models 1350G/1355G November, 2016 Bulgarian Brooks Instrument Brooks Instrument. Brooks Instrument : (1) . (2) Brooks Instrument (PED) 0,5 bar (g) 25 mm 1" (inch), (PED).
  • Page 32 P ed instalací si p e t te následující instrukce! Spole nost Brooks Instrument konstruuje, vyrábí a testuje tento produkt tak, aby splnil mnoho národních a mezinárodních standard . P ístroje musí být ádn nainstalovány, používány a udržovány tak, aby byl zajišt n jejich nep etržitý provoz v rámci normálních technických specifikací. Musíte dodržovat následující...
  • Page 33 Om kvalitet af signalkabler, kabeltilslutninger og koblinger: Brooks tilbyder kabler af højest kvalitet, som er tilpasset CEE kvalificeringens forskrifter. Hvis man vælger at bruge egne kabler, skal man vælge et kabel som har den nødvendige afskærmning for at sikre 100 % mod udefra kommende støj.
  • Page 34 Lees ze voordat u verder gaat! Brooks Instrument ontwerpt, produceert en test haar producten zodanig dat ze voldoen aan vele nationale en internationale normen. Deze producten moeten correct worden geïnstalleerd, bediend en onderhouden zodat ze binnen hun normale specificaties blijven werken.
  • Page 35 Olulised juhised Enne kasutamist lugege hoolikalt läbi! Brooks Instrument konstrueerib, valmistab ja katsetab oma tooteid selliselt, et need vastaksid paljudele riiklikele ja rahvusvahelistele standarditele. Ainult nõuetekohane paigaldamine, kasutamine ja hooldamine tagab toodete katkematu talitluse tavaspetsifikatsiooni raames. Brooks Instrumenti toodete paigaldamisel, kasutamisel ja hooldamisel tuleb täita alljärgnevaid juhiseid ja integreerida need asjakohasesse ohutusprogrammi.
  • Page 36 PED direktiiviä koskevat määräykset löytyvät käyttöoppaan ’’Tekniset tiedot” -luvusta. Käyttöoppaassa kuvatut tuotteet ovat 2014/34/EU EU-direktiivin mukaisia. Kaikki Brooks Instrumentin virtausmittarit kuuluvat ryhmään 1. Laitteet, jotka ovat suurempia, kuin 25 mm tai 1 tuuma, ovat PED I, II, III kategorien mukaisia.
  • Page 37 AVERTISSEMENT: n’utilisez pas cet instrument au-delà des spécifications énumérées dans le manuel d’utilisation. Le non-respect de cet avertissement peut entraîner de graves blessures et / ou endommager l’équipement. • Si vous ne comprenez pas l’une des instructions, prenez contact avec un représentant de Brooks Instrument pour obtenir des explications. •...
  • Page 38 Produkte mit einer Größe von 25 mm oder 1“ (inch) oder kleiner sind Sound Engineering Practice (SEP). Europäische Verordnung zur elektromagnetischen Verträglichkeit (EMV) Geräte von Brooks Instrument (elektrischer und elektronischer Art) mit CE-Zeichen haben den Test auf Einhaltung der Verordnung zur elektromagnetischen Verträglichkeit (EMV Richtlinie 2014/30/EU) erfolgreich bestanden.
  • Page 39 Section A Essential Instructions Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG Brooks ® Sho-Rate Models 1350G/1355G November, 2016 Greek Brooks Instrument Brooks Instrument. ’ Brooks Instrument. : (1) . (2) Brooks Instrument. (PED) 0,5 bar (g) 25 mm (PED).
  • Page 40 üzemeltetni és karbantartani ahhoz, hogy mindenképpen a normál m ködési tartományuknak megfelel en üzemelhessenek. Az alábbi utasításokat be kell tartani, és be kell építeni a munkavédelmi programba a Brooks Instrument termékeinek telepítése, üzemeltetése és karbantartása során.
  • Page 41 Direttiva europea relativa alla compatibilità elettromagnetica (EMC) Le apparecchiature (elettriche/elettroniche) Brooks Instrument dispongono del marchio CE ed hanno superato positivamente i test per i requisiti di compatibilità elettromagnetica (Direttiva EMC 2014/30/EU). In ogni caso bisogna prestare particolare attenzione alla scelta dei cavi di segnale utilizzati per le apparecchiature con marchio CE.
  • Page 42 Lai nodrošin tu šo izstr d jumu turpm ku darb bu atbilstoši noteiktajiem parametriem, tie ir pareizi j uzst da, j lieto un j apkopj. Uzst dot, lietojot „Brooks Instrument” izstr d jumus un veicot to apkopi, ir j iev ro šie nor d jumi un j iek auj tie j su droš bas programm .
  • Page 43 SP JIMAS: nenaudokite šio prietaiso viršydami instrukcijoje ir eksploatacijos vadove nurodytus techninius duomenis. Nesilaikydami šio sp jimo galite sunkiai susižeisti ir (arba) sugadinti rang . Jei nesuprantate koki nors nurodym , kreipkit s „Brooks Instrument“ atstov , kad paaiškint . Paisykite vis sp jim , persp jim ir nurodym , pažym t ant gaminio arba pateikt su juo.
  • Page 44 Produkty o wielko ci 25 mm lub 1 cala lub mniejsze podlegaj zaleceniom „Uznanej Praktyki In ynierskiej” (SEP). Europejska dyrektywa dotycz ca kompatybilno ci elektromagnetycznej (EMC) Urz dzenia elektryczne / elektroniczne firmy Brooks Instrument posiadaj ce oznaczenie CE, przesz y pozytywnie testy pod k tem spe niania przez nich wymogów kompatybilno ci elektromagnetycznej (Dyrektywa EMC 2014/30/EU).
  • Page 45 Ler antes de proceder! A Brooks Instrument projecta, fabrica e testa os seus produtos de forma a satisfazer numerosas normas nacionais e internacionais. Estes equipamentos devem ser instalados, utilizados e mantidos de forma adequada, e devem funcionar dentro da sua gama de utilização. As instruções seguintes devem ser, durante a instalação, uso e/ou manutenção dos equipamentos da Brooks Instrument, apreendidas e integradas no plano de...
  • Page 46 În m sura în care indica iile c r ii ma inii nu sunt suficient de l muritoare, lua i leg tura cu reprezentantul Brooks Instrument pentru clarificarea problemei.
  • Page 47 Pre íta pred inštaláciou! Brooks Instrument svoje výrobky projektuje, vyrába a testuje takým spôsobom, aby tieto vyhoveli domácim aj medzinárodným normám. Tieto zariadenia je potrebné predpísaným spôsobom inštalova , prevádzkova a udržiava , na zabezpe enie ich spo ahlivej a normálnej prevádzky v celom pracovnom rozsahu.
  • Page 48 Pred servisom morate odstraniti tlak v obdelovalni liniji. e potrebujete rezervne dele, zagotovite, da usposobljeno osebje uporablja rezervne dele, ki jih je odobrila družba Brooks Instrument. Neodobreni deli in postopki lahko vplivajo na u inkovitost delovanja izdelka ali ogrozijo varno upravljanje postopka.
  • Page 49 ¡Léalos primero! El Brooks Instrument proyecta, fabrica y prueba sus productos de manera que éstos respondan a numerosas normas nacionales e internacionales. Dichas instalaciones deben ser emplazadas, operadas y mantenidas adecuadamente, para que puedan marchar de todas formas en conformidad con el alcance normal de funcionamiento.
  • Page 50 Läs detta innan du fortsätter! Brooks Instrument konstruerar, tillverkar och testar sina produkter med syfte att uppfylla alla nationella och internationella standarder. Dessa produkter måste installeras på rätt sätt, handhas och underhållas för att de skall fungera kontinuerligt enligt deras normala specifikation. De följande anvisningarna bör följas och integreras till Ert säkerhetsprogram varje gång när Brooks Instruments produkter installeras, handhas och underhålls.
  • Page 51 Installation and Operation Manual X-VA-1350G-eng Part Number: 541B205AAG ® Brooks Sho-Rate Models 1350G/1355G November, 2016...
  • Page 52 BROOKS SERVICE AND SUPPORT Brooks is committed to assuring all of our customers receive the ideal flow solution for their application, along with outstanding service and support to back it up. We operate first class repair facilities located around the world to provide rapid response and support.

This manual is also suitable for:

Sho-rate 1355g

Table of Contents