3.10 Adjusting the level of conductivity

The "conductivity" of the water used to wash the fabrics varies from zone to zone: the conductimetric sensor is
calibrated to a standard value; any major variations in the level of conductivity may affect the final drying result
(i.e. the washing may be too dry or too humid):
These variations can be noticed above all in "slightly humid" or "iron ready" cycles; the "cupboard dry" cycles
are not affected by the variations of the conductivity.

3.10.1 Procedure

To access adjustment mode:
1. Turn the programme selector to switch on the
appliance.
2. In selection mode (set-up), simultaneously press
the following buttons:
1 and 5 on models with big LCD.
1 and 5 on models with small LCD.
1 and 4 on models with small LCD and alarm
LEDs
1 and 3 (start/pause) on models without LCD
3. Continue to hold down the buttons until the
buzzer sounds (about 5 seconds).
Adjusting the level of conductivity:
Press the START/PAUSE button sequentially: the
conductivity level varies and is signalled by the
switching on of the LEDs or of the horizontal seg-
ments of the last digit.
Memorizing the new setting:
1. Simultaneously push the buttons previously
pushed.
2. Hold down the buttons till the buzzer sounds
(about 5 seconds).