9.5 Table of alarms

Alarm
Description
E00
No alarm.
Canister fill pump triac
E21
faulty.
Triac "sensing" circuit for the
E22
canister fill pump faulty
Signal frequency of the sen-
E31
sor too high.
Signal frequency of the sen-
E32
sor too low.
Appears in the displaying of
E33
the last alarm, if position 8 is
NOT OK.
E45
Door closure sensor.
Current absorption of the
E57
drum rotation motor out of
range.
Current absorption of drum
E58
rotation motor too high
Drum motor control board
E59
does not receive the correct
signals from the main board
Power supply of motor con-
E5H
trol board too low.
Power supply of motor con-
E5C
trol board too high.
Faulty communication
E5E
between motor control
board and main board.
E5F
Motor control board faulty.
Insufficient heating (maxi-
E61
mum time exceeded)
Power relay to heater unit
E62
faulty
Intervention of auto-reset
E63
thermostat on the heater
unit.
- ADL
Possible fault
---
Wiring faulty.
Electronic board faulty.
Electronic board faulty.
Electronic board faulty.
Wiring faulty.
Damaged brushes / faulty.
Electronic board faulty.
Wiring faulty.
Damaged brushes / faulty.
Electronic board faulty.
Door interlock faulty.
Wiring faulty.
Electronic board faulty.
Motor faulty.
Wiring faulty.
Motor control main board faulty.
Motor faulty.
Wiring faulty.
Motor control main board faulty.
Motor faulty.
Wiring faulty.
Motor control board faulty.
Wiring faulty.
Motor control board faulty.
Motor control board faulty.
Wiring faulty.
Motor control board faulty.
Main electronic board faulty
Motor control board faulty.
Heater unit faulty.
Wiring faulty.
NTC sensor faulty/out of place.
Electronic board faulty.
Heater unit faulty.
Wiring faulty.
Electronic board faulty.
Thermostat faulty.
Heater unit faulty.
Wiring faulty.
Electronic board faulty.
39/62
Action/machine status
---
Cycle interrupted.
Cycle interrupted.
Alarm activated only dur-
ing
diagnostics.
Cycle interrupted.
Alarm activated only dur-
ing
diagnostics.
Cycle interrupted.
Cycle interrupted.
Cycle interrupted
Cycle interrupted.
Cycle interrupted.
Cycle interrupted.
Cycle interrupted
Cycle interrupted
Cycle paused.
Forced cooling.
circuit
Disconnects the power
supply to the heater unit.
If the problem does not re-
occur, the alarm is memo-
rized and the cycle contin-
ues. If the fault persists
after several attempts to
supply power, alarm E62
is generated.
599 71 49 26

Advertisement