Trade-wind 30303RC Installation Instructions & Use & Care Manual

Advertisement

PERFORMANCE · QUALITY · CUSTOMER SERVICE
FRONT TO
MODEL
BACK
WIDTH
30303RC
20"
30"
30363RC
20"
36"
30366RC
20"
36"
30423RC
20"
42"
30426RC
20"
42"
30486RC
20"
48"
P L E A S E R E M O V E T H E R I G H T S I D E B A F F L E F I L T E R
T O L O C A T E Y O U R N E W R E M O T E C O N T R O L .
Before beginning installation, please thoroughly read and become familiar with these instructions. Installation
and service must be completed by a qualified installer. Failure to properly install this product may void the
warranty.
Installer:
Please leave Installation Instructions with the range hood.
Owner:
Please keep Installation Instructions for local electrical inspector's use and for future reference.
WARNINGS:
Must be followed carefully to avoid personal injury.
IMPORTANT:
Must be followed carefully to avoid damage and incorrect installation.
TIPS:
Contains helpful information to facilitate installation.
WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have any questions, please contact the
manufacturer at the address or telephone number listed in the warranty.
b) Before servicing or cleaning unit, switch power off at service panel, lock service panel, and lock the service
disconnection means to prevent power from being switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
CAUTION: For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
WARNING! TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite.
Heat oils slowly on low or medium settings.
P R O V E R B S
3-SPEED
INTERNAL
CFM
BLOWER
390
390
600
390
600
600
* * * A T T E N T I O N * * *
READ AND SAVE THESE INSTRUCTIONS
2 2 : 2 9
I N S T A L L A T I O N I N S T R U C T I O N S
3 0 0 0 S L I M L I N E S E R I E S
1
© 2 0 2 3
T R A D E - W I N D
U S E & C A R E G U I D E
R A N G E H O O D S
REVISED: JANUARY 1, 2024
M A N U F A C T U R I N G ,
L L C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 30303RC and is the answer not in the manual?

Questions and answers

Summary of Contents for Trade-wind 30303RC

  • Page 1 3 0 0 0 S L I M L I N E S E R I E S R A N G E H O O D S PERFORMANCE · QUALITY · CUSTOMER SERVICE REVISED: JANUARY 1, 2024 3-SPEED FRONT TO INTERNAL MODEL BACK WIDTH BLOWER 30303RC 20" 30" √ 30363RC 20" 36" √ 30366RC 20" 36"...
  • Page 2: Installation Instructions

    To reduce the risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls, ceilings, cabinets or into attics, crawl spaces, or garages. TO ACCESS THE INSTALLATION INSTRUCTIONS FOR YOUR TRADE-WIND® PRODUCT, PLEASE SCAN THE QR CODE:...
  • Page 3 ELECTRONIC 3-SPEED DUCT S/S BAFFLE REMOTE TOUCH FRONT TO INTERNAL MODEL FLITERS CONTROL BACK WIDTH COLOR LIGHTS COLLAR CONTROL BLOWER 30303RC 20" 30" √ √ √ 7" √ 30363RC 20" 36" √ √ √ 7" √ 30366RC 20" 36" √...
  • Page 4: Part 1: Planning The Installation

    PART 1: PLANNING THE INSTALLATION CAUTION: 1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. To reduce the risk of fire and to properly exhaust air, the hood must be exhausted to outside air. Never exhaust into a wall, an attic or a concealed area in the building.
  • Page 5: Mounting Holes

    FILTER BRACKETS, ELECTRICAL COMPONENTS OR UL LABEL. The Trade-Wind® 3000 Series range hood comes with x2 triangular mounting brackets that attach to the top of the hood and the wall to support the hood and minimize "rocking". There are x4 holes in each bracket that mount against the wall.
  • Page 6 HOUSE ELECTRICAL PANEL GREEN WHITE 120V BLACK H O O D DIAGRAM 1: ALL MODELS WITH FACTORY INSTALLED INTERNAL MOTOR/BLOWER. PART 4: USE AND CARE CAUTION: The edges of the stainless steel are extremely sharp. To ensure safety, wear gloves when handling all parts. WARNING: Do not operate the blower/ventilator system without the filters in place, or with dirty, grease laden filters.
  • Page 7: Range Of Remote Control

    LED LIGHT BULBS: Trade-Wind® liners are designed for MR16/GU10 LED light bulbs. They can be purchased at most home or grocery stores. The bulbs provided with the unit are 3. 5 watt, 350 lumens, and 3000K (warm white color temperature).
  • Page 8: Warranty

    For Service: If you need service on your TRADE-WIND® Ventilation Product, visit our website at: www. t- wusa. com and click on the warranty tab. Fill out the simple form providing the model number, serial number, date of purchase, and brief description of the problem.
  • Page 9: Building Codes

    B E S T P R A C T I C E S V E N T I N G I N S T A L L A T I O N I N S T R U C T I O N S F O R R A N G E H O O D S A N D W O O D H O O D L I N E R S ( A L L M O D E L S ) PERFORMANCE ·...
  • Page 10 d. ) Duct runs for 600 – 1200 CFM hood/liner models should not exceed 35 linear feet with two 90-degree elbows and two 45-degree elbows, a damper and a roof or wall cap. Longer runs or additional elbows will result in decreased ventilation performance.
  • Page 11 No Mushroom Cap Style No "Goose-Neck" Style Only use a shape that looks like the picture shown. Call TRADE-WIND® Customer Service for any questions. 6. ATTACHING DUCT TO HOUSE FRAMEWORK The ventilation system should be attached to the framework in such a manner that the weight of the duct and fittings is supported with no stress on the duct joints, fittings or on the hood/liner.