Trade-wind VSL430 BF Installation Instructions & Use & Care Manual

Trade-wind VSL430 BF Installation Instructions & Use & Care Manual

Designer series liners

Advertisement

Designer Series Models
Model
Width
28 – 3/8‖
VSL430 BF
34 - 3/8‖
VSL436 BF
40 - 3/8‖
VSL442 BF
46 - 3/8‖
VSL448 BF
28 - 3/8‖
VSL430-4 BF
34 - 3/8‖
VSL436-4 BF
40 - 3/8‖
VSL442-4 BF
28 - 3/8‖
VSL430-6 BF
34 - 3/8‖
VSL436-6 BF
40 - 3/8‖
VSL442-6 BF
46 - 3/8‖
VSL448-6 BF
46 - 3/8‖
VSL442-12 BF
46 - 3/8‖
VSL448-12 BF
*These models connect to an In-Line, Roof or
Wall-Mounted Remote Blower. The blower used
determines the CFM.
Before beginning installation, please thoroughly read and become familiar with these instructions. Installation and
service must be completed by a qualified installer. Failure to properly install this product may void the warranty.
Installer:
Please leave Installation Instructions with the range hood liner.
Please keep Installation Instructions for local electrical inspector's use and for future reference.
Owner:
WARNINGS: Must be followed carefully to avoid personal injury.
IMPORTANT: Must be followed carefully to avoid damage or incorrect installation.
TIPS: Contain helpful information to facilitate installation.
WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO
PERSONS OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have any questions, please contact the
manufacturer at the address or telephone number listed in the warranty.
b) Before servicing or cleaning unit, switch power off at service panel, lock service panel, and lock the service
disconnection means to prevent power from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Item No. 0BL-00-012
Revised 07/19/2010
Type of
CFM
Motor &
Blower
*
Remote
*
Remote
*
Remote
*
Remote
410
Internal
410
Internal
410
Internal
660
Internal
660
Internal
660
Internal
660
Internal
1360
Internal
1360
Internal
READ AND SAVE THESE INSTRUCTIONS
Copyright © 2008 Universal Metal Industries, Inc.
INSTALLATION INSTRUCTIONS &
USE & CARE GUIDE
®
Trade-Wind
Designer Series Liners
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VSL430 BF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Trade-wind VSL430 BF

  • Page 1: Installation Instructions

    USE & CARE GUIDE ® Trade-Wind Designer Series Liners Designer Series Models Type of Motor & Model Width Blower 28 – 3/8‖ VSL430 BF Remote 34 - 3/8‖ VSL436 BF Remote 40 - 3/8‖ VSL442 BF Remote 46 - 3/8‖ VSL448 BF Remote 28 - 3/8‖...
  • Page 2 CAUTION -- For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. WARNING – TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite.
  • Page 3: Planning The Installation

    In-Line Blowers, it is highly recommended that the blower NOT ® be attached directly to the liner or in a chase immediately above the liner unless a Trade-Wind brand duct silencer is installed between the blower and liner and neoprene lined FC Clamps are used. FC Clamps are ®...
  • Page 4 Installation Instructions provided with the duct silencer. ® Given that most installations are different, a back-draft damper is not provided with this unit. Trade-Wind back ® draft dampers are also available from your local Trade-Wind dealer.
  • Page 5 THROUGH FILTER BRACKETS, ELECTRICAL COMPONENTS OR UL LABEL. ® Because the Trade-Wind Standard Series Liner was designed for various wood hood applications, no mounting holes have been pre-drilled. This allows the liner to be attached in most any area of the canopy that has a wood frame support, e.g., the back, sides or top.
  • Page 6 HALOGEN LIGHT BULBS: ® Trade-Wind liners are designed for Par 20 halogen lamps. They can be purchased at most home or grocery stores, e.g., Lowe’s, McCoy’s, Menards, Ace True Value and Home Depot. Item No. 0BL-00-012 Revised 07/19/2010 Copyright ©...
  • Page 7 (either in-line or roof top). If the ventilator is rated in watts rather than ® amps, divide the watts by 120 and this will give you the amperage rating. The Trade-Wind liner is supplied with a 5.0 amp variable speed fan control.
  • Page 8: Wiring Diagrams

    Liner VSL442-12 BF VSL448-12 BF Diagram 2: Models Connected to Variable Speed Blowers House Electrical Models: Panel 120V Red Green VSL430 BF VSL436 BF White (N) VSL442 BF 120V Black VSL448 BF Ventilator Green, Ground Liner Diagram 3: Models Connected to 3-Speed Roof or Wall Mounted Blowers IMPORTANT--Connections to 3-Speed Blowers Require a 5-wire connection to the blower.
  • Page 9: Warranty

    Designer Series Kitchen Ventilation Products What is Covered ® Universal Metal Industries, Inc., warrants its Trade-Wind Standard Series kitchen ventilation products to the original user, to be free of defects in materials and workmanship for one (1) year from the date of purchase.

Table of Contents