7200 Series Models:
No Blower
1250 CFM
7236
7236-12
7242
7242-12
7248
7248-12
7254
7254-12
7260
7260-12
7266
7266-12
CONTENTS:
Part 1 - Planning The Installation
Part 2 - Electrical Connection
Part 3 - Direction of Vent and Securing The Hood
Part 4 - Use & Care
Before beginning installation, please thoroughly read and become familiar with these instructions. Installation and
service must be completed by a qualified installer. Failure to properly install this product may void the warranty.
Please be advised that the Trade-Wind
that does not have a roof over the Range Hood to protect it from direct rain or potential water ingress. This Hood
should be installed with a MINIMUM of three (3) feet of weather proof roof coverage on all sides that are not
protected from direct rain by an adjacent wall.
It is required that all duct work and roof openings be thoroughly sealed with the applicable tape and/or roof sealant
to prevent ingress of water.
Installer:
Please leave Installation Instructions with the range hood liner.
Owner:
Please keep Installation Instructions for local electrical inspector's use and for future reference.
WARNINGS: Must be followed carefully to avoid personal injury.
IMPORTANT: Must be followed carefully to avoid damage or incorrect installation.
TIPS: Contain helpful information to facilitate installation.
WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO
PERSONS OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have any questions, please contact the
manufacturer at the address or telephone number listed in the warranty.
b) Before servicing or cleaning unit, switch power off at service panel and lock service panel and lock the service
disconnection means to prevent power from being switch on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such as a tag to the service panel.
Item No. 0BL-00-010
Revised 08/25/14
2300 CFM
N/A
N/A
N/A
7254-23
7260-23
7266-23
®
7200 Series Range Hood MAY NOT be installed on a Patio or Lanai area
READ AND SAVE THESE INSTRUCTIONS
Copyright (C) 2008, Universal Metal Industries, Inc.
INSTALLATION INSTRUCTIONS &
USE & CARE GUIDE
Trade-Wind
®
BBQ 7200 Series Range Hood
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 7236 and is the answer not in the manual?

Questions and answers

Summary of Contents for Trade-wind 7236

  • Page 1 Failure to properly install this product may void the warranty. ® Please be advised that the Trade-Wind 7200 Series Range Hood MAY NOT be installed on a Patio or Lanai area that does not have a roof over the Range Hood to protect it from direct rain or potential water ingress. This Hood should be installed with a MINIMUM of three (3) feet of weather proof roof coverage on all sides that are not protected from direct rain by an adjacent wall.
  • Page 2 CAUTION -- For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. WARNING – TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite.
  • Page 3: Planning The Installation

    Some TRADE-WIND ® 7200 Series Range Hoods are for wall mounting only. For safe and secure wall mounting, the TRADE-WIND ® Hood should be mounted to a solid vertical surface of sufficient width to allow for mounting of the Hood. The horizontal surface should extend from a vertical plane to the point directly in front of the exhaust roof cap (or wall cap).
  • Page 4 IMPORTANT: All dimensions are nominal +/- 1/8”. FRONT VIEW Model # (No Blower) (1250 CFM) 7236 7236-12 7242 7242-12 7248 7248-12 **INSTALLER MUST DUCT TAPE PERFORATED KNOCKOUT 7254 7254-12 AREA TO ENSURE SEALED SMOKE CAPTURE AREA. 7260 7260-12 7266 7266-12...
  • Page 5 IMPORTANT: All dimensions are nominal +/- 1/8”. FRONT VIEW Model # (No Blower) (2300 CFM) **INSTALLER MUST DUCT TAPE PERFORATED KNOCKOUT 7254 7254-23 AREA TO ENSURE SEALED SMOKE CAPTURE AREA. 7260 7260-23 7266 7266-23 TOP/REAR VIEW Item No. 0BL-00-010 Revised 08/25/14 Copyright (C) 2008, Universal Metal Industries, Inc.
  • Page 6: Electrical Connection

    This Hood requires a 120 Volt, 60 Hertz electrical supply of an individual properly grounded branch circuit protected by a 15 or 20 Amp circuit breaker. TRADE-WIND ® 7200 Series Range Hood is supplied with a 6.0 Amp three speed fan control.
  • Page 7 PART 3 Determining Direction of Vent and Securing the Hood MOUNTING HOLES: TRADE-WIND ® Because the 7200 Series Range Hood was designed for all applications, no mounting holes have been pre-drilled. This allows for custom applications for mounting. The hood should be attached to the framing through the top and back, whenever possible.
  • Page 8: Warranty

    Some features may be slightly different than shown on product literature. ® For more information, please contact your Trade-Wind Representative 800 West Grant Street, Phoenix, AZ 85007 800 875-3654 Phone...
  • Page 9: Venting Installation Instructions

    Addendum   t o   I nstallation   Best   P ractices   Instructions   Venting   I nstallation   I nstructions   Model:     7 200   S eries IMPORTANT:     P roblems   c aused   b y   i mproper   i nstallations   a re   n ot   c overed   b y   t he   m anufacturer’s   w arranty.    ...
  • Page 10   Damper   i n   R oof   C ap   o r   W all   C ap   In   v entilation   s ystems   u tilizing   a   r oof   c ap   o r   w all   c ap   w ith   a   b uilt-­‐in   d amper,   d o   n ot   i nstall   a n   a dditional   i n-­‐line   d amper.   T wo   d ampers   are  ...
  • Page 11     D uct   S izing   C hart   a nd   A rea   C alculations     Ventilator   D ischarge   P ort   Minimum   D uct   S ize   Minimum   D ischarge   S ize   o f   R oofcap   Duct  ...

Table of Contents