Installation Instructions
I
MAKE ELECTRICAL CONNECTION TO THE UNIT
m REMOVE JUNCTION
BOX
1. Removethe junction box cover bg removing the front
two screws.
2. Removethe junction box bg removing the top and
bottom rear screws. Note how the tabs on the lower
left side of the junction box serve to hold the side in
place.This will help when the box is being reinstalled.
Unitconnector
jJ
,]unction
box cover
_
Junction
box
121 CONNECT THE CORDSET
Plug the connector, provided in the Direct Connect Kit,
fully into place in the unit mating connector. Be sure
the locking tabs at the sides are engaged.
NOTE:Order Kit RAK4OO2CW to enable a quick
disconnect inside the junction box.
I
131 ATTACH CONDUIT
I. Usethe round knockout at the bottom of the junction
box to attach conduit coming from the branch circuit.
Removethe knockout, attach the conduit and bring
wires into the junction box. Leave6" of wire free at the
end of the conduit to allow connections to be made.
2. If a fuse and fuseholder are to be used, the
knockout at the top of the box is for mounting
a Bussfuseholder. Be sure the fuse and fuseholder are
of the same rating as the branch circuit. Leadwires at
the fuse can be either soldered in place or attached
using UL-listed 1/4" female (receptacle)crimp
connectors. Follow local codes.
_-I REINSTALL JUNCTION
BOX
• Reinstallthe junction box bg engaging the left tabs
on the lower right face of the unit, aligning the screw
holes at the top and bottom and driving the two
screws until secure. Be sure that all wire leads are
inside the box and not pinched between the box and
the unit. The green insulated ground wire from the unit
MUSTbe connected to the branch circuit ground wire.
Make all wire connections bg using appropriate
UL-listed electrical connectors and techniques
(black to black, white to white and green to green).
rsi REINSTALLJUNCTION BOX COVER
1. Carefullg tuck all wires and connections back inside
the junction box. Be sure there are no loose
connections or strag uninsulated wires exposed.
2. Placethe junction box cover in place. Replacethe two
screws removed earlier and tighten securelg.