∗ Be sure to confirm the polarity when connecting.
1. Removal of product
1) Shut off the fluid supply and release the fluid pressure in the system.
2) Shut off the power supply.
3) Confirm that the valve temperature has dropped sufficiently before removing the product.
2. Replace or clean filters (strainers) periodically.
1) Replace filters after one year of use, or earlier if the pressure drop reaches 0.1 MPa.
2) Clean strainers when the pressure drop reaches 0.1 MPa.
3. Exhaust the drainage from air filters periodically.
If condensation in the drain bowl is not emptied on a regular basis, the bowl will overflow and allow the
condensation to enter the compressed air lines. This causes the malfunction of pneumatic equipment.
If the drain bowl is difficult to check and remove, the installation of a drain bowl with an auto drain option
is recommended.
4. Low frequency operation
Switch valves at least once every 30 days to prevent malfunction.
Also, in order to use them under the optimum state, conduct a regular inspection biannually.