Advantech DS-450 Series User Manual
Advantech DS-450 Series User Manual

Advantech DS-450 Series User Manual

Palm-size mini-pc with hdmi x2 + function port x1

Advertisement

Quick Links

User Manual
DS-450 Computer
Palm-Size Mini-PC with
HDMI x2 + Function Port x1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DS-450 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Advantech DS-450 Series

  • Page 1 User Manual DS-450 Computer Palm-Size Mini-PC with HDMI x2 + Function Port x1...
  • Page 2 No part of this manual may be reproduced, copied, translated, or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. The information provided in this manual is intended to be accurate and reliable.
  • Page 3 Product Warranty (2 years) Advantech warrants the original purchaser that each of its products will be free from defects in materials and workmanship for two years from the date of purchase. This warranty does not apply to any products that have been repaired or altered by persons other than repair personnel authorized by Advantech, or products that have been subject to misuse, abuse, accident, or improper installation.
  • Page 4 Consult the dealer or an experienced radio/TV technician for assistance.  Technical Support and Assistance Visit the Advantech website at www.advantech.com/support to obtain the latest product information. Contact your distributor, sales representative, or Advantech's customer service center for technical support if you need additional assistance. Please have the following information ready before calling: –...
  • Page 5 Warnings, Cautions, and Notes/Avertissements, mises en garde et remarques Warning! Warnings indicate conditions that if not observed can cause personal injury! Les avertissements indiquent des conditions qui, si elles ne sont pas observées, peuvent causer des blessures! Caution! Cautions are included to help prevent hardware damage and data losses.
  • Page 6 Safety Instructions Read these safety instructions carefully. Lisez attentivement ces instructions de sécurité. Retain this user manual for future reference. Conservez ce manuel de l'utilisateur pour référence ultérieure. Disconnect the equipment from all power outlets before cleaning. Use only a damp cloth for cleaning.
  • Page 7 Assistance, please contact Advantech for further information. DISCLAIMER: These instructions are provided according to IEC 704-1 standards. Advantech disclaims all responsibility for the accuracy of any statements contained herein. AVERTISSEMENT: Cet ensemble d'instructions est donné conformément à la norme CEI 704-1.
  • Page 8 DS-450 Series Part Number Remark DS-450GB-U0A1E DS-450, J6412, Barebones, 4GB LPDDR4 DS-450GB-U1A1E DS-450, J6412, Barebones, 8GB LPDDR4 DS-450GB-U0A1U DS-450, J6412, Barebones, 4GB LPDDR4, for US DS-450GB-U1A1U DS-450, J6412, Barebones, 8GB LPDDR4, for US DS-450GB-U0A1U DS-450GB-U1A1U DS-450GB-U2A1U DS-450GB-U3A1U DS-450GB-U4A1U DS-450GB-U5A1U DS-450GB-U0A1E DS-450GB-U1A1E...
  • Page 9: Table Of Contents

    1.6.5 Shock During Vibration ..............4 1.6.6 EMC ....................4 Chapter Hardware Configuration......5 DS-450 Series I/O ..................6 Figure 2.1 DS-450 I/O..............6 2.1.1 LED ....................6 Figure 2.2 Power ................. 6 Figure 2.3 LED - HDD..............6 2.1.2 Power On/off ................. 6 Figure 2.4 Power Button ..............
  • Page 10 Chapter BIOS Settings ........11 BIOS Introduction..................12 Entering the Setup .................. 13 3.2.1 Main Setup.................. 13 3.2.2 Advanced..................14 3.2.3 Advanced → CPU Configuration ..........15 3.2.4 Advanced → Power & Performance ........... 16 3.2.5 Advanced → PCH-FW Configuration ......... 18 3.2.6 Advanced →...
  • Page 11: Chapter 1 General Introduction

    Chapter General Introduction This chapter gives background information on DS-450 series.
  • Page 12: Introduction

    System Memory: 4GB or 8GB DDR4 on board  Storage: M.2 2242 M Key (mSATA)  SUSI: SUSI is Advantech unique hardware management that provided in stan-  dard DS-450 Win10 IoT image. Below function are included. – Watchdog Timer –...
  • Page 13: Mechanical Specification

    Mechanical Specification 1.4.1 Dimension 160 x 115 x 44 mm (L x W x H) Figure 1.1 Dimensions 1.4.2 Weight 0.7 kg  Power Requirements 1.5.1 Adapter Power Max: 19V , 3.42A, 65W  1.5.2 RTC Battery Battery: 3V 210mAH CR2032M1S8-LF ...
  • Page 14: Shock During Vibration

    1.6.5 Shock During Vibration 20 G, IEC 60068-2-27, half sine, 11 ms duration  1.6.6 CE, FCC Class B  DS-450 User Manual...
  • Page 15: Chapter 2 Hardware Configuration

    Chapter Hardware Configuration This chapter introduces external IO and the installation of DS-450 series Hardware.
  • Page 16: Ds-450 Series I/O

    DS-450 Series I/O Figure 2.1 DS-450 I/O 2.1.1 Below LED indicator means power on status when it shows green. Figure 2.2 Power Below LED indicator means SSD status when it shows orange. Figure 2.3 LED - HDD 2.1.2 Power On/off Push below button to power on/off DS-450.
  • Page 17: Usb 3.0 Gen2

    2.1.3 USB 3.0 Gen2 DS-450 supports 2 x USB 3.0 interfaces. The USB interfaces complies with USB UHCI, Rev. 3.0 standards. Please refer to Table 2.5 for its pin assignments. USB 3.0 connectors contain legacy pins to interface with USB 2.0 devices, and a new set of pins for USB 3.0 connectivity.
  • Page 18: Wifi Antenna

    Table 2.3: Right Side LED: Green LED Link Status Always turn on without transmitting/receiving data Activity status Flash Left side LED: Green/Orange LED Status Display 10Mbps Always off 100Mbps Green 1000Mbps Orange 2.1.5 WiFi Antenna DS-450 provides two WiFi antenna connectors to connect with SMA antenna. Figure 2.7 SMA connector 2.1.6 Function Port...
  • Page 19: Jumpers Location

    Jumpers Location Figure 2.8 Jumper Layout 2.2.1 Clear CMOS (JCMOS1) Table 2.5: Clear CMOS (JCMOS1) Location JCMOS1 Setting Function (1-2)* Normal operation (Default) (2-3) Clear CMOS 2.2.2 AT/ATX (PSON1) Table 2.6: AT/ATX (PSON1) Location PSON1 Setting Function (1-2) (2-3)* ATX (Default) DS-450 User Manual...
  • Page 20: Hardware Installation

    Hardware Installation 2.3.1 Mounting Bracket Installation Find 4 pcs of M3(L=5mm) screws to affix the mounting brackets on system bottom. (The screws and mounting brackets are both included in the system accessory box) Trouvez 4 vis M3 (L = 5 mm) pour fixer les supports de montage au bas du système. (Les vis et les supports de montage sont tous deux inclus dans la boîte d'accessoires du système) 2.3.2...
  • Page 21: Bios Settings

    Chapter BIOS Settings...
  • Page 22: Bios Introduction

    BIOS Introduction AMI’s BIOS has been integrated into motherboards for over two decades. With the AMI’s BIOS Setup program, users can modify BIOS settings and control various sys- tem features. This chapter describes the basic navigation of the DS-450 BIOS setup screens.
  • Page 23: Entering The Setup

    BIOS supports your CPU. If there is no number assigned to the patch code, please contact an Advantech application engineer to obtain an up- to-date patch code file. This will ensure that your CPU‘s system status is valid.
  • Page 24: Advanced

    3.2.2 Advanced DS-450 User Manual...
  • Page 25: Advanced → Cpu Configuration

    3.2.3 Advanced → CPU Configuration Intel (VMX) Virtualization  Enable or Disable Intel VMX Virtualization support. Active Processor Cores  Enable all or 1/2/3. MonitorMWait  Enable or disable MonitorMWait support. DS-450 User Manual...
  • Page 26: Advanced → Power & Performance

    3.2.4 Advanced → Power & Performance DS-450 User Manual...
  • Page 27 Boot performance mode  Max non-Turbo performance. Max battery Turbo performance Intel SpeedStep  Enable or disable Intel SpeedStep support. Turbo mode  Enable or disable Turbo mode. C states  Enable or disable C states. DS-450 User Manual...
  • Page 28: Advanced → Pch-Fw Configuration

    3.2.5 Advanced → PCH-FW Configuration ME State  Enable or disable ME State. ME Unconfig on RTC Clear  Enable or disable ME Unconfig on RTC Clear. DS-450 User Manual...
  • Page 29 3.2.5.1 Advanced → PCH-FW Configuration → Firmware update Configuration Me FW Image Re-Flash  Enable or disable Me FW Image Re-Flash. FW Update  Enable or disable FW Update. DS-450 User Manual...
  • Page 30 3.2.5.2 Advanced → PCH-FW Configuration → PTT Configuration TPM Device Selection  Select PTT or dTPM. DS-450 User Manual...
  • Page 31: Advanced → Acpi Settings

    3.2.6 Advanced → ACPI Settings Enable ACPI Auto Configuration  Enable or disable ACPI Auto Configuration. Enable Hibernation  Enable or disable Hibernation. ACPI Sleep State  Select S3 (Suspend to RAM) or suspend Disabled. DS-450 User Manual...
  • Page 32: Advanced → It5121 Hw Monitor

    3.2.7 Advanced → IT5121 HW Monitor DS-450 User Manual...
  • Page 33: Advanced → It5121 Super Io Configuration

    3.2.8 Advanced → IT5121 Super IO Configuration ACPI Shutdown Temperature  Disabled 70° C/158° F 75° C/167° F 80° C/176° F 85° C/185° F 90° C/194° F 95° C/205° F Watch Dog Timer (PreBoot)  Enable or disable Watch Dog Timer (PreBoot). Watch Dog Timer ...
  • Page 34 → → 3.2.8.1 Advanced IT5121 Super IO Configuration Serial Port 1 Configuration Serial Port  Enable or disable Serial Port. Change Settings  Auto or Change IRQ setting. DS-450 User Manual...
  • Page 35: Advanced → Trusted Computing

    3.2.9 Advanced → Trusted Computing Security Device Support  Enable or disable Security Device Support. SHA256 PCR Bank  Enable or disable SHA256 PCR Bank. Pending operation  None or TPM Clear. DS-450 User Manual...
  • Page 36: Advanced → S5 Rtc Wake Settings

    3.2.10 Advanced → S5 RTC Wake Settings Wake system from S5  Enable or disable Wake system from S5. 3.2.11 Advanced → USB Configuration DS-450 User Manual...
  • Page 37 XHCI Hand-off  Enable or disable XHCI Hand-off. USB Mass Storage Driver Support  Enable or disable USB Mass Storage Driver Support. USB transfer time-out  Configure time for USB transfer time-out. Device reset time-out  Configure time for Device reset time-out. Device power-up delay ...
  • Page 38: Advanced → Network Stack Configuration

    3.2.12 Advanced → Network Stack Configuration Network Stack  Enable or disable Network Stack. Chipset DS-450 User Manual...
  • Page 39: Chipset → System Agent (Sa) Configuration

    3.3.1 Chipset → System Agent (SA) Configuration VT-d  Enable or disable VT-D. → → 3.3.1.1 Chipset System Agent (SA) Configuration Memory Configuration DS-450 User Manual...
  • Page 40: Chipset → Pch-Io Configuration

    3.3.2 Chipset → PCH-IO Configuration Onboard LAN Controller  Enable or disable Onboard LAN Controller. LAN1 PXE OpROM  Enable or disable LAN1 PXE OpROM. PCIE Wake  Enable or disable PCIE Wake. PinCntrl Driver GPIO Scheme  Enable or disable PinCntrl Driver GPIO Scheme. DS-450 User Manual...
  • Page 41 → → 3.3.2.1 Chipset PCH-IO Configuration SATA Configuration SATA Controller(s)  Enable or disable SATA Controller(s). SATA Mode Selection  Select AHCI. Aggressive LPM Support  Enable or disable Aggressive LPM Support. SATA Controller Speed  Select Default or Gen1 or Gen2 or Gen3. M.2 M-Key →...
  • Page 42 → → 3.3.2.2 Chipset PCH-IO Configuration USB Configuration XHCI Compliance Mode  Enable or disable XHCI Compliance Mode. USB3 Port 1  Enable or disable USB3 Port 1. USB3 Port 2  Enable or disable USB3 Port 2. USB2 Port 1 ...
  • Page 43 → → 3.3.2.3 Chipset PCH-IO Configuration PCI Express Configuration PCI Express Root Port 2  Enable or disable PCIe of M.2. DS-450 User Manual...
  • Page 44: Security

    Security Administrator Password  Set/Configure Administrator Password. User Password  Set/Configure User Password. DS-450 User Manual...
  • Page 45: Security → Secure Boot

    3.4.1 Security → Secure Boot Secure Boot  Enable or disable Secure Boot. Secure Boot Mode  Select Custom or Standard. DS-450 User Manual...
  • Page 46 → 3.4.1.1 Security Secure Boot DS-450 User Manual...
  • Page 47: Boot

    Boot Setup Prompt Timeout  Configure Setup Prompt Timeout. Bootup Numlock State  Select On or off. Quiet Boot  Enable or disable Quiet Boot. DS-450 User Manual...
  • Page 48: Save & Exit

    Save & Exit Save Changes and Exit  Save your changes and exit BIOS setting. Discard Changes and Exit  Discard your changes and exit BIOS setting. Save Changes and Reset  Save your changes and reset the system. Discard Changes and Reset ...
  • Page 49 DS-450 User Manual...
  • Page 50 No part of this publication may be reproduced in any form or by any means, such as electronically, by photocopying, recording, or otherwise, without prior written permission from the publisher. All brand and product names are trademarks or registered trademarks of their respective companies. © Advantech Co., Ltd. 2023...

Table of Contents