Advertisement

Quick Links

SPARTUS® EasyARC
216P
User's manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EasyARC and is the answer not in the manual?

Questions and answers

Summary of Contents for Spartus EasyARC

  • Page 1 SPARTUS® EasyARC 216P User’s manual...
  • Page 2 Therefore, our offer covers such a wide assortment of products. Thank you very much for your trust in our company. We would like to invite you to familiarize yourself with the remaining products and offer at www.spartus. info or directly at a local distributor of SPARTUS® products.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS 1. SAFE USE – HAZARDS ASSOCIATED WITH ARC WELDING AND PLASMA CUTTING ....2 1.1 General safety rules ................................... 2 1.2 Electric shock can kill ................................2 1.3 Welding arc radiation can be dangerous ......................... 3 1.4 Vapours and gases can be dangerous ..........................3 1.5 Noise can be harmful ................................
  • Page 4: Safe Use - Hazards Associated With Arc Welding And Plasma Cutting

    USER’S MANUAL 1. SAFE USE – HAZARDS ASSOCIATED WITH ARC WELDING AND PLASMA CUTTING Arc welding and plasma cutting are processes feeder fitted with spool and harness). Care that can pose hazards for the operator and per- shall be taken during manual handling. sons in his vicinity.
  • Page 5: Welding Arc Radiation Can Be Dangerous

    USER’S MANUAL • Power supply must never be connected Such radiation can be direct or reflected from before the accessories of SK sockets/con- surfaces such as bright metals and light colo- nectors are properly installed in the device. ured objects. •...
  • Page 6: Noise Can Be Harmful

    USER’S MANUAL Arc welding and allied processes produce wel- in case of an emergency, are in the imme- ding fume which may pollute the atmosphere diate vicinity. surrounding the work. Welding fume is a vary- • In closed rooms or in certain circumstances ing mixture of airborne gases and fine particles during outdoor operations, it may be re- which, if inhaled or swallowed, constitute a...
  • Page 7: Fire Or Explosion Hazard

    USER’S MANUAL source, observed for an adequate period after its c) effective maintenance of sound protection termination. devices, • „Hot spots” and immediate surroundings d) indication as „ear protection areas” where should be observed until their temperature applicable, has dropped to normal. e) restriction of entry to these „ear protection 1.6.2 Explosion hazard areas”...
  • Page 8: Other Hazards

    USER’S MANUAL 1.7.4 Moving elements can be dangerous cylinder valve socket when the valve is being opened. • Special valve shield should always be in- stalled during cylinder transportation or when the cylinder is not used. OTHER HAZARDS Arc welding and allied processes carrying other All protective elements and device housing hazards not listed before.
  • Page 9: Symbols Used In Instructions

    USER’S MANUAL WARNING The maximum voltage of 15kV. Accidental pressing of the microswitch results in unintentional arc ignition. Never bring a bare hand close to the electrode, when the device is connected to a power source. 1.9 SYMBOLS USED IN INSTRUCTIONS We use this symbol to pay your attention about important information.
  • Page 10: Assesment Of Area

    Methods of reducing electromagnetic interference are listed in detail in the standard EN 60974-9 – „Arc welding equipment – Part 9: Installation and use”. 4. CONFORMITY WITH STANDARDS SPARTUS® EasyARC 216P is in conformity with the relevant Union harmonization legislation: LVD 2014/35/UE Low Voltage Directive...
  • Page 11: General Description

    The welding machine and its equipment can be placed in a handy case included in the set. Examples of use: light industrial, agricultural farm, portable repair, workshop, manufacturing. 5.1 PURPOSE OF USE SPARTUS® EasyARC 216P is designed for: • Manual Metal Arc welding (MMA), • Manual Metal Arc welding (MMA) with VRD, •...
  • Page 12: Technical Parameters Of Device

    Dimensions [mm] 280 × 130 × 200 7. INSTALLATION AND USE WARNING! SPARTUS® EasyARC series is intended for professional and industrial applications. Installation and use of the device may only be carried out appropriately trained professionals. It is forbidden to carry out work related to metalworking (for example grinding, drilling, etc.) near the welding device, especially near the vents.
  • Page 13: Movement And Handling

    USER’S MANUAL 7.2 MOVEMENT AND HANDLING Please take special care when moving the welding machine. The device should be moved by using specially designed transport lugs. If transport handle is damaged, then it needs to be repaired at an authorized service center. 7.3 DESCRIPTION OF CONSTRUCTION 7.3.1 Front panel / rear panel Transport handle...
  • Page 14: Connecting To Power Supply

    USER’S MANUAL 7.4 CONNECTING TO POWER SUPPLY Requirements for power network parameters (voltage, permissible range of mains voltage fluctuations etc.) are given in the table with technical parameters of device and on the rating plate of welding machine. Before connecting the unit to the power source: •...
  • Page 15: Device Control Panel - Using

    USER’S MANUAL 7.6 DEVICE CONTROL PANEL – USING Numeric display Welding parameters adjustment knob EASYARC 216P DISPLAY PANEL OPERATION...
  • Page 16: Maintenance

    USER’S MANUAL Electrode size (default unit is mm) Indicator for welding current / Hot Start /Arc Force Plate thickness (default unit is mm) Pulse ON/ Pulse OFF Function selection and adjustment knob: MMA / Hot Start / Arc Force / TIG Lift VRD ON / OFF function (VRD ON available only in LIFT TIG mode) Over temperature warning Frequency (Hz) of pulse...
  • Page 17: Environmental Protection

    10. TROUBLESHOOTING Not all problems with functioning of the device, are the evidence of failure. You can independently carry out an analysis in search of probable failure. In case of doubt, please contact to SPARTUS® dealer or authorized service center.
  • Page 18 USER’S MANUAL Capacity on electrode holder is too small. Electrode holder cable is too hot, Cable is too thin. output terminals are too hot. Socket is loosen. TIG WELDING PROBLEMS The problem of obtaining adequate Too low welding current. weld penetration. Improper welding parameters.
  • Page 19 A masterly combination of high quality production, excellent parameters and ergonomics – these are fea- tures of the SPARTUS® Master series of devices, which were created with demanding welding jobs in mind. Precision, functionality, excellent parameters and resistance to high workloads –...
  • Page 20 Videopresentation of products Subscribe to the channel SPARTUS.INFO...