Configuration; Introduction; Configuring Using Setup Mode; Entering Setup Mode - Fluidwell B Series User Manual

Flowrate indicator/totalizer
Hide thumbs Also See for B Series:
Table of Contents

Advertisement

User manual
5

CONFIGURATION

5.1

INTRODUCTION

This chapter describes how technicians can use configuration settings to configure the B-Smart for
optimal functionality. Configuration is done in SETUP mode, using the front keys.
Also, the B-Smart can be configured by PC with our Remote Configuration Tool. Besides the
possibility to configuring the unit, this solution offers up- and download and printing of all settings.
The Remote Configuration Tool software package can be downloaded free of charge from our
website at www.fluidwell.com/software, and installed on a Microsoft
also contains a quick-start manual with detailed instructions to successfully connect the PC and your
B-Series.
Connection between the service port of the B-Smart and the PC is made by using a special cable (to
be ordered separately). For more info see
5.2

CONFIGURING USING SETUP MODE

For an overview of Operating modes, see
Changing settings may influence current operation
In SETUP mode the unit remains fully operational. Make sure the product is not being used for any
application when changing settings.
5.2.1

ENTERING SETUP MODE

1. Press the SELECT-key for 7 seconds. During this, the symbol
be prompted to enter a password.
2. The
SET-UP
READY
5.2.2

NAVIGATING THE SETUP MENU

The SETUP menu contains several menu groups, which each contain various menu items. Each
menu item has a unique number which is displayed at the bottom of the display. Additionally, each
menu item is expressed with a keyword.
The menu number is a combination of two figures separated by a dot:
● the first figure indicates the selected menu group (e.g. 1. TOTAL).
● the second figure indicates the menu item (e.g. 1.1 UNIT).
The following image shows the layout of the menu structure:
Navigate the SETUP menu with the following functions:
SELECT-key
This key selects the next function in the list (e.g. 1. à 1.1. à 1.2. à 1.... à 1.)
select
When the top of the list is reached, it will return to the function group selection level.
Page 10
indicator is now activated on the display and the
1.3
1.2
select
1.1
1.
Fig. 6:
SETUP menu layout and navigation
Section 6.5.5: Service port [»23]
Section 4.1.1: Operating modes [»8]
RUN
READY
2.2
2.1
2.
FUNCTION GROUP
®
®
Windows
PC. The package
.
.
will be flashing. You may
SET-UP
READY
indicator is deactivated.
3.1
3.
clear
FW_B-SMART_M_v0401-01_EN
B-Smart

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the B Series and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

B-smartB-connectedB-basic

Table of Contents