F043-T
TEMPERATURE INDICATOR
WITH HIGH / LOW TEMPERATURE ALARMS
Signal input sensor: PT100
Alarm output: one temperature alarm.
Options: Intrinsically Safe.
F-Series - Field mounted indicators for safe and hazardous areas. More info: www.fluidwell.com/fseries

Advertisement

Table of Contents
loading

Summary of Contents for Fluidwell F043-T

  • Page 1 F043-T TEMPERATURE INDICATOR WITH HIGH / LOW TEMPERATURE ALARMS Signal input sensor: PT100 Alarm output: one temperature alarm. Options: Intrinsically Safe. F-Series - Field mounted indicators for safe and hazardous areas. More info: www.fluidwell.com/fseries...
  • Page 2: Safety Instructions

     This unit must be installed in accordance with the EMC guidelines (Electro Magnetic Compatibility).  Do connect a proper grounding to the aluminum casing as indicated if the F043-T has been supplied with the 115-230V AC power-supply type PM. The green / yellow wire between the back-casing and removable terminal-block may never be removed.
  • Page 3: About The Operation Manual

    This operation manual describes the standard unit as well as most of the options available. For additional information, please contact your supplier. A hazardous situation may occur if the F043-T is not used for the purpose it was designed for or is used incorrectly. Please carefully note the information in this operating manual indicated by the pictograms: A "warning"...
  • Page 4: Table Of Contents

    Safety rules and precautionary measures ....................... 2 About the operation manual ..........................3 Contents manual .............................. 4 Introduction ..........................5 1.1. System description of the F043-T ..................5 Operational ..........................6 2.1. General ..........................6 2.2. Control panel .......................... 6 2.3.
  • Page 5: Introduction

    Fig. 1: Typical application for the F043-T. Configuration of the unit The F043-T has been designed to be implemented in many types of applications. For that reason, a SETUP-level is available to configure your F043-T according to your specific requirements.
  • Page 6: Operational

     Take careful notice of the " Safety rules, instructions and precautionary measures " in the front of this manual. This chapter describes the daily use of the F043-T. This instruction is meant for users / operators. 2.2. CONTROL PANEL The following keys are available: Fig.
  • Page 7: Operator Information And Functions

    SETUP-settings. The signal generated by the connected sensor is measured by the F043-T in the background, whichever screen refresh rate setting is chosen. After pressing a key, the display will be updated very quickly during a 30 second period, after which it will slow-down again.
  • Page 8 Page 8  Temperature alarm When the actual temperature is outside the allowed range, an alarm message will be displayed indicating the type of alarm: "LO TEMP", "HI TEMP". The alarm is terminated automatically as soon as the temperature is within its range again. ...
  • Page 9: Configuration

    Operating Manual before carrying out its instructions.  The F043-T may only be operated by personnel who are authorized and trained by the operator of the facility. All instructions in this manual are to be observed.
  • Page 10 Page 10 Matrix structure SETUP-level: SCROLLING THROUGH SETUP-LEVEL Selection of function-group and function: SETUP is divided into several function groups and functions. Each function has a unique number, which is displayed below the word "SETUP" at the bottom of the display. The number is a combination of two figures. The first figure indicates the function-group and the second figure the sub-function.
  • Page 11 Page 11 To change or select a value: To change a value, use  to select the digits and  to increase that value. If the new value is invalid, the increase sign or decrease-sign will be displayed while you are programming.
  • Page 12: Overview Functions Setup Level

    - 1 sec - 3 sec - 15 sec - 30 sec - off BATTERY MODE operational - shelf SENSOR NR OF WIRES 2 - 3 - 4 FILTER 0 - 99 OTHERS TYPE / MODEL F043-T SOFTWARE VERSION 03.xx.xx SERIAL NO. xxxxxxx PASS CODE 0000 - 9999 TAGNUMBER 0000000 - 9999999 3.2.3.
  • Page 13: Display

    When used with the internal battery option, the user can expect reliable measurement over a long period of time. The F043-T has several smart power management functions to extend the battery life time significantly. Two of these functions can be set:...
  • Page 14: Sensor

    The output signal of a sensor does mirror the actual temperature. This FILTER signal is measured several times a second by the F043-T. The value measured is a "snap-shot" of the real temperature as it will be fluctuating. With the help of this digital filter a stable and accurate reading can be obtained while the filter temperature can be set to a desired value.
  • Page 15: Installation

    Operating Manual before carrying out its instructions.  The F043-T may only be operated by personnel who are authorized and trained by the operator of the facility. All instructions in this manual are to be observed.
  • Page 16: Dimensions- Enclosure

    Page 16 4.3. DIMENSIONS- ENCLOSURE Aluminum enclosures: 75 mm (2.95") 112 mm (4.40") 130 mm (5.12") 12mm 12mm 30mm 30mm 24mm 24mm M20 x 1,5 6 x M12 36mm 36mm 30mm 30mm M16 x 1,5 M16 x 1,5 1/2"NPT M20 x 1,5 0.12"...
  • Page 17 Page 17 GRP enclosures: 75 mm (2.95") 112 mm (4.40") 130 mm (5.12") HK back box: (flat bottom) 75 mm (2.95") 118 mm (4.65”) 25mm 25mm D=20mm D=20mm 12mm 12mm 30mm 30mm 24mm 24mm D=12mm D=16mm D=16mm D=20mm 36mm 36mm 0.12”...
  • Page 18: Installing The Hardware

    Page 18 4.4. INSTALLING THE HARDWARE 4.4.1. INTRODUCTION  Electro static discharge does inflict irreparable damage to electronics! Before installing or opening the unit, the installer has to discharge himself by touching a well-grounded object.  This unit must be installed in accordance with the EMC guidelines (Electro Magnetic Compatibility).
  • Page 19: Terminal Connectors With Power Supply - Type : Pb / Px

    PT100 - 2 WIRE PT100 - 3 WIRE PT100 - 4 WIRE Fig. 9: Overview of terminal connectors F043-T-(PB / PX) and options. REMARKS: TERMINAL CONNECTORS: Terminals 1-4; Sensor input type T – PT100: See drawing above for the proper connection of a 2, 3 or 4 wire PT100 sensor. The sensor signal which will be processed once per second with a 16 bits accuracy.
  • Page 20: Intrinsically Safe Applications

    Safety Instructions  Certificates, safety values, control drawing and declaration of compliance can be found in the document named: “Fluidwell F0..-T-XI - Documentation for Intrinsic Safety”.  For installation under ATEX directive: this intrinsically safe device must be installed in accordance with the Atex directive 94/9/EC and the product certificate KEMA 05ATEX1168 X.
  • Page 21: Terminal Connectors Intrinsically Safe Applications

    FWCD-0005. Tamb CSA Certificate nr: CSA.08.2059461 – FM Project ID: 3033306 -40°C ... +70°C Made in Veghel, The Netherlands by Fluidwell bv -40°F ... +158°F KEMA 05ATEX1168 X Battery powered applications: II 1 G Ex ia IIC T4 Replace with certified II 1 D Ex iaD 20 IP 65 / 67 T 100°C...
  • Page 22: Configuration Examples Intrinsically Safe Applications

    Type PX: as standard, all intrinsically safe products are supplied with terminal 4 and 5 to power the product externally. 5.3. CONFIGURATION EXAMPLES INTRINSICALLY SAFE APPLICATIONS: Configuration example Configuration example IIA - IIB and IIC application - F043-T-PX-XI-ZB HAZARDOUS AREA SAFE AREA TERMINAL CONNECTORS F0-series = max.
  • Page 23: Battery Replacement Instructions

    Page 23 5.4. BATTERY REPLACEMENT INSTRUCTIONS FW-LiBAT-001 - INST001 Fig. 14: Battery replacement instructions Intrinsically Safe Battery. HF043TEN_v0402_04 Atex_IECEx_CSA_FM...
  • Page 24: Maintenance

    Operating Manual before carrying out its instructions.  The F043-T may only be operated by personnel who are authorized and trained by the operator of the facility. All instructions in this manual are to be observed.
  • Page 25: Appendix A: Technical Specification

    Page 25 APPENDIX A: TECHNICAL SPECIFICATION GENERAL Display Type High intensity reflective numeric and alphanumeric LCD, UV-resistant. Digits Seven 17mm (0.67") and eleven 8mm (0.31"). Various symbols and measuring units. Refresh rate User definable: 8 times/sec - 30 secs. Type ZB (option) Tri-color configurable LED-backlight - green, amber with red flashing during alarm.
  • Page 26 Page 26 Data protection Type EEPROM backup of all settings. Data retention at least 10 years. Pass code Configuration settings can be pass code protected. Hazardous area (option) Intrinsically safe ATEX approval: Type XI II 1 G Ex ia IIC T4 II 1 D Ex iaD 20 IP 65 / 67 T 100°C IECEx approval: Ga Ex ia IIC T4...
  • Page 27: Appendix B: Problem Solving

    Page 27 APPENDIX B: PROBLEM SOLVING In this appendix, several problems are included that can occur when the F043-T is going to be installed or while it is in operation. Range error  Range error: the input value is at least 5% above or below the calibrated measurement range.
  • Page 28: Index Of This Manual

    Page 28 INDEX OF THIS MANUAL actual settings low current alarm 8, 27 low-battery alarm output function main-function alarm values maintenance delay time alarm manual version set alarm operator level model alarm output operational alarm values operator level backlight pass code 14, 27 alarm color power supply...
  • Page 29: List Of Figures In This Manual

    Fig. 7: Dimensions GRP enclosures....................17 Fig. 8: Grounding aluminum enclosure with option PF..............18 Fig. 9: Overview of terminal connectors F043-T-(PB / PX) and options..........19 Fig. 10: Example serial number......................20 Fig. 11: Label information Intrinsically Safe application..............21 Fig.
  • Page 30: Notes

    Page 30 NOTES HF043TEN_v0402_04 Atex_IECEx_CSA_FM...
  • Page 31 Page 31 NOTES HF043TEN_v0402_04 Atex_IECEx_CSA_FM...
  • Page 32 64 pass code 0000 65 tagnumber 0000000 Fluidwell bv HF043TEN_v0402_04 Atex_IECEx_CSA_FM PO box 6 Voltaweg 23 Website: www.fluidwell.com 5460 AA Veghel 5466 AZ Veghel Find your nearest representative: www.fluidwell.com/representatives The Netherlands The Netherlands Copyright Fluidwell bv - 2012 - HF110AEN_v0501_03...

This manual is also suitable for:

F series

Table of Contents