I/O signals (CN1) - output signals
Pin No.
Signal Name
31
Common
ALM+
32
ALM-
27
/TGON+
28
/TGON-
29
/S-RDY+
30
/S-RDY-
33
PAO
34
/PAO
35
PBO
36
/PBO
19
PCO
20
/PCO
37 (1)
ALO1
38 (1)
ALO2
39 (1)
ALO3
Shell
FG
25
Speed
/V-CMP+
26
/V-CMP-
25
Position
/COIN+
26
/COIN-
-
Reserved
/CLT
/VLT
/BK
/WARN
/NEAR
3
-
13
16
17
18
23
24
48
49
50
Note: 1. Pin numbers in parentheses () indicate signal grounds.
2. The functions allocated to /TGON, /S-RDY, and /V-CMP (/COIN) output signals can be changed by using the parameters. /CLT, /VLT, /
BK, /WARN and /NEAR signals can also be changed.
I/O signals (CN8) - safety signals
Pin No.
Signal Name
4
Common
/HWBB1+
3
/HWBB1-
6
/HWBB2+
5
/HWBB2-
8
EDMI+
7
EDMI-
1
Reserved
-
2

Terminal specifications

Symbol
Name
L1, L2 or
Main circuit AC input terminal
L1, L2, L3
U, V, W
Servo motor connection terminal
L1C, L2C
Control power input terminal
24V, 0V
Frame ground
B1/ ⊕, B2, B3
Main circuit DC output terminal
1,
2
DC reactor connection terminal for
suppressing power supply harmonic
waves

Encoder connector (CN2)

Pin No.
Signal Name
1
E5V
2
E0V
3
BAT+
4
BAT–
5
S+
6
S–
Sigma-5 servo drive
Function
Servo alarm: Turns OFF when an error is detected.
Detection during servo motor rotation: detects when the servo motor is rotating at a speed higher than the motor speed
setting.
Servo ready: ON if there is no servo alarm when the control/main circuit power supply is turned ON.
Phase-A signal
Two-phase pulse encoder output pulse signal
Phase-B signal
Phase-C signal
Zero-point pulse signal
Alarm code output: Outputs 3-bit alarm codes.
Connected to frame ground if the shield wire of the I/O signal cable is connected to the connector shell.
Turns ON when whether the motor speed is within the setting range is detected and if it matches the reference speed
value.
Turns ON when the number of position error pulse reaches the value set.
Reserved terminals
The functions allocated to /TGON, /S-RDY, and /V-CMP (/COIN) can be changed by using the parameters.
/CLT, /VLT, /BK, /WARN and /NEAR signals can also be changed.
Terminals not used.
Do not connect.
Function
Hard wire baseblock input 1
Hard wire baseblock input 2
Monitored circuit status output 1:
ON when the hard wire baseblock function is normally activated.
Terminals not used.
Do not connect.
Function
AC power input terminals for the main circuit
Terminals for outputs to the servo motor.
AC power input terminals for the control circuit.
24V DC power input terminals for the control circuit.
Ground terminal. Ground to a maximum of 100 Ω. (class 3).
Up to 400 W:
From 500 W to 5 kW:
the wire between B2 and B3 and connect an external regenerative resistor between
Normally, short
1 and
If a countermeasure against power supply harmonic waves is needed, connect a DC reactor
between
1 and
2.
Function
Encoder power supply + 5 V
Encoder power supply ground
Battery + (used only with absolute encoder)
Battery – (used only with absolute encoder)
Encoder serial signal input
Encoder serial signal input
If the regenerative capacity is insufficient, connect an external regenerative resistor
(option) between B1/ ⊕ and B2.
Normally short B2 and B3. If the internal regenerative resistor is insufficient, remove
B1/ ⊕ and B2.
2.
7