Sigma-5 Analog/Pulse Reference Servo Drive

General specifications

Speed control range
Speed
Load variance
variance
Voltage variance
Temperature variance
Frequency characteristics
Torque control accuracy (Repeatability)
Soft start time setting
Speed
Reference voltage
reference
input
Input impedance
Circuit time constant
Torque
Reference voltage
reference
input
Input impedance
Circuit time constant
Feedforward compensation
Position completed width setting
Input pulse type
Command
Input pulse form
pulse
Input pulse frequency
Control signal
Position signal output
Sequence input signal
Sequence output signal
USB
Interface
Communica-
Communications standard
tions
Function
Automatic load inertia detection
Dynamic brake (DB)
Regenerative processing
Overtravel (OT) prevention function
Encoder divider function
Electronic gearing
Internal speed setting function
Protective functions
Analog monitor functions for supervision
Panel operator
Display functions
Panel operator keys
Safety functions
Others
Sigma-5 servo drive
1:5000
During 0 to 100% load ±0.01% max. (at rated speed)
Rated voltage ±10%:0% (at rated speed)
25 ±25 °C: ±0.1 % max. (at rated speed)
1.6 kHz
±1%
0 to 10 s (acceleration, deceleration can each be set.)
±6 VDC (forward motor rotation if positive reference) at rated speed: Set at delivery
Variable setting range: ±2 to ±10 VDC at rated speed/ max. input voltage: ±12 V
Approx. 14 kΩ
Approx. 30 µs
±3 VDC (forward rotation if positive reference) at rated torque: Set at delivery
Variable setting range ±1 to ±10 VDC at rated torque reference, max. input voltage: ±12 V
Approx. 14 KΩ
Approx. 30 µs
0 to 100% (setting resolution: 1%)
0 to 1073741824 command units (setting resolution: 1 command unit)
Sign + pulse train, 90° phase displacement 2-phase pulse (A-phase+ B-phase) or CCW/CW pulse train
Non-insultated line driver (+5 V level) , open collector.
0 to 4 Mpps (200 Kpps max. at open collector)
Clears error pulse by external signal
A-phase, B.phase, C-phase: line driver output.
Servo ON, P control (or control mode switching, forward/reverse motor rotation by internal speed setting, zero
clamp, command pulse inhibit), forward/reverse run prohibit, forward/reverse current limit (or internal speed
switching), alarm reset.
Servo alarm, alarm codes (3-bit output): CN1 output terminal is fixed
It is possible to output three types of signal form incl.: positioning complete, speed coincidence detection, servo-
motor rotation detection, servo ready, current limit detection, speed limit detection, brake release, warning, NEAR.
Personal computer
Compliant with USB1.1 standard (12 Mbps)
Status display, parameter settings, adjustment functions, utility functions, alarm traceback display, JOG run/au-
totuning operations and graphing functions for speed/torque command signal, etc
Automatic motor parameter setting. One parameter rigidity setting.
Operates during main power OFF, servo alarm, servo OFF or overtravel
Internal resistor included in models from 500 W to 5 kW. Regenerative resistor externally mounted (option).
DB stop, deceleration stop or coast to stop during P-OT, N-OT operation
Optional division pulses possible
0,01< Numerator/Denominator<100
3 speeds may be set internally
Overcurrent, overvoltage, low voltage, overload, regenerative error
Integrates analog monitor connector for supervision of the speed and torque reference signals, etc.
Number of channels: 2 (Output voltage: +/-10V DC)
CHARGE, 7-segments LEDx5
Used to set parameters (4 keys)
Hard wire base block signal and status monitor (fixed output) of safety circuit
Reverse connection, zero search, automatic motor discrimination function, and DC reactor connection terminal
for high frequency power suppression function.