I/O signals (CN1) - output signals
Pin No.
Signal Name
3
Common
ALM+
4
ALM-
1
/BK+
(/SO1+)
2
/BK-
(/SO1-)
23
/SO2+
24
/SO2-
25
/SO3+
26
/SO3-
16
FG
17
PAO
18
/PAO
19
PBO
20
/PBO
21
PCO
22
/PCO
5
Reserved
-
I/O signals (CN8) - safety signals
Pin No.
Signal Name
4
Common
/HWBB1+
3
/HWBB1-
6
/HWBB2+
5
/HWBB2-
8
EDMI+
7
EDMI-
1
Reserved
-
2
Terminal specifications
Symbol
Name
L1, L2 or
Main circuit AC input terminal
L1, L2, L3
U, V, W
Servo motor connection terminal
L1C, L2C
Control power input terminal
24V, 0
Frame ground
B1/ ⊕, B2, B3
Main circuit DC output terminal
or
B1, B2, B3
1,
2
DC reactor connection terminal for
suppressing power supply harmonic
waves
Encoder connector (CN2)
Pin No.
Signal Name
1
E5V
2
E0V
3
BAT+
4
BAT–
5
S+
6
S–
Sigma-5 servo drive
Function
Servo alarm: Turns OFF when an error is detected.
Brake interlock signal
Controls the brake. The brake is released when the signal turns ON.
Allocation can be changed to general-purpose output signals (/SO1+, /SO1-).
General-purpose output signal.
Note: Set the parameter to allocate a function.
Signal ground:
Connected to frame ground if the shield wire of the I/O signal cable is connected to the connector shell.
Phase-A signal
Dividing ratio can be set by parameter
(proper line receiver is SN75175 manufactured by Texas instruments or the equivalent
corresponding to MC3486)
Phase-B signal
Phase-C signal
Terminal not used. Do no connect.
Function
Hard wire baseblock input 1
Hard wire baseblock input 2
Monitored circuit status output 1:
ON when the hard wire baseblock function is normally activated.
Terminals not used.
Do not connect.
Function
AC power input terminals for the main circuit
Terminals for outputs to the servo motor.
AC power input terminals for the control circuit.
24V DC power input terminals for the control circuit.
Ground terminal. Ground to a maximum of 100 Ω. (class 3).
Up to 400 W:
From 500 W to 5 kW:
the wire between B2 and B3 and connect an external regenerative resistor between
Normally, short
1 and
If a countermeasure against power supply harmonic waves is needed, connect a DC reactor
between
1 and
2.
Function
Encoder power supply + 5 V
Encoder power supply ground
Battery + (used only with absolute encoder)
Battery – (used only with absolute encoder)
Encoder serial signal input
Encoder serial signal input
If the regenerative capacity is insufficient, connect an external regenerative resistor
(option) between B1/ ⊕ and B2.
Normally short B2 and B3. If the internal regenerative resistor is insufficient, remove
B1/ ⊕ and B2.
2.
9