This parameter determines the default
settings for output voltage and frequen
cy.
You can choose from 3 presets:
Device type
version
This parameter can be changed from
the Admin user level.
This parameter has 2 modes:
Operation mode
This parameter can be changed from
the Expert user level.
This parameter determines the ratio
between positive and negative ions the
anti-static bar produces.
The default value is 0, producing an
equal number of positive (+) and nega
tive (-) ions. This parameter ranges
Balance offset
from -100 (100% negative ions) to 100
(100% positive ions).
This parameter can be changed from
the Expert user level (and the Opera
tion mode parameter then must be set
to Manual).
This parameter determines the default
positive output voltage (when the Bal
ance offset parameter is set to 0).
Output voltage
The default output voltage positive val
positive set
ue is determined by the Device type
version parameter.
point
This value can be adjusted from the
Admin user level for specific applica
tions.
This parameter determines the default
negative output voltage (when the Bal
Output voltage
ance offset parameter is set to 0).
negative set
The default output voltage negative
value is determined by the Device type
point
version parameter.
This value can be adjusted from the
Speed: web speed >500 m/min,
•
web distance 50-500 mm
Hybrid: web speed 0-500 m/min,
•
web distance 100-500 mm
Distance: web distance 100-1000
•
mm
Fixed (default): the anti-static bar
•
uses the default settings.
Manual: parameters related to the
•
output voltage and frequency can
be changed, it is also possible to
use the anti-static bar in CLFB
mode.