Omron L7Z Quick Start Manual page 33

Table of Contents

Advertisement

Param.
Name
Num.
U1-08 Output power in kW
U1-09 Torque reference in % of the motor rated torque
Shows input ON/OFF status.
Input terminal
U1-10
status
Shows output ON/OFF status.
Output termi-
U1-11
nal status
Inverter operating status.
Operation sta-
U1-12
tus
U1-13 Cumulative operation time
U1-20 Frequency reference after soft-starter
U1-34 OPE fault parameter
U1-51 Max Current during acceleration
U1-52 Max Current during deceleration
U1-53 Max Current during Top speed
U1-54 Max Current during leveling speed
U1-55 Number of travels
Fault Trace Data
U2-01 Current fault
U2-02 Last fault
U2-03 Reference frequency at fault
U2-04 Output frequency at fault
U2-05 Output current at fault
U2-06 Motor speed at fault
U2-07 Output voltage reference at fault
U2-08 DC bus voltage at fault
U2-09 Output power at fault
U2-10 Torque reference at fault
U2-11 Input terminal status at fault
U2-12 Output terminal status at fault
Param.
Description
Num.
U2-13 Operation status at fault
U2-14 Cumulative operation time at fault
Fault History Data
U3-01
1: FWD command
U3-04
(S1) is ON
1: REV command
U3-05
(S2) is ON
1: Multi input 1
U3-08
(S3) is ON
1: Multi input 2
U3-09
(S4) is ON
1: Multi input 3
U3-14
(S5) is ON
U3-15
1: Multi input 4
(S6) is ON
1: Multi input 5
U3-20
(S7) is ON
* The following errors are not recorded in the error log:
1: Multi-function
contact output 1
(M1-M2) is ON
1: Multi-function
Digital Input Function Selections
contact output 2
(M3-M4) is ON
1: Multi-function
contact output 3
(M5-M6) is ON
Not used
(Always 0).
1: Error output
(MA/MB-MC) is
ON
20 to
Run
1: Zero speed
1: Reverse
1: Reset signal
input
1: Speed agree
1: Inverter ready
1: Minor fault
Digital Output Function Selections
1: Major fault
Name
to
Last fault to Fourth last fault
to
Cumulative operation time at fault 1 to 4
to
Fifth last to tenth last fault
to
Accumulated time of fifth to tenth fault
CPF00, 01, 02, 03, UV1, and UV2.
3
Multi-step speed reference 1
4
Multi-step speed reference 2
Jog frequency command (higher priority than multi-step
6
speed reference)
F
Not used (Set when a terminal is not used)
14
Fault reset (Reset when turned ON)
External fault; Input mode: NO contact/NC contact, Detec-
2F
tion mode: Normal/during operation
80
Nominal Speed Selection (d1-09)
81
Intermediate Speed Selection (d1-10)
82
Releveling Speed Selection (d1-13)
83
Leveling Speed Selection (d1-17)
84
Inspection Run Selection (d1-14)
During run 1 (ON: run command is ON or voltage is being
0
output)
Inverter operation ready; READY: After initialization or no
6
faults
8
During baseblock (NO contact, ON: during baseblock)
Car stuck/undertorque detection 1 NO (NO contact, ON:
B
Overtorque/undertorque detection)
F
Not used. (Set when the terminal is not used.)
10
Minor fault (ON: Alarm displayed)
Car stuck/undertorque detection 1 NC (NC Contact, OFF:
17
Torque detection)
1A
During reverse run (ON: During reverse run)
40
Brake Release Command
41
Output Contactor Close Command
Description
EN-30

Advertisement

Table of Contents
loading

Table of Contents