Ordering Information

■ List of Models
Input type
DC voltage/current, NPN
DC voltage/current, PNP

Specifications

■ Ratings
Supply voltage
Operating voltage range
Power consumption (see note)
Insulation resistance
Dielectric strength
Noise immunity
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
EMC
Approved standards
Weight
Note: A control power supply capacity greater than the rated capacity is required when the Digital Panel Meter is turned ON. Do not forget to take
this into consideration when using several Digital Panel Meters. When power is supplied, all indicators will light and outputs will be OFF.
When using startup compensation time operation, the display will read "00000" and all outputs will be OFF.
K-8
1/32 DIN Digital Panel Meter
Supply
Output
voltage
24 VDC
Dual relays (SPST-NO)
Three NPN open collector
Dual relays (SPST-NO)
Three PNP open collector
24 VDC
85% to 110% of the rated supply voltage
2.5 W max. (at max. DC load with all indicators lit)
20 M min. (at 500 VDC) between external terminal and case.
Insulation provided between inputs, outputs, and power supply.
1,000 VAC for 1 min between external terminal and case.
Insulation provided between inputs, outputs, and power supply.
480 V on power supply terminals in normal mode, 1,500 V in common mode, 1 s, or 100 ns for square-
wave noise with 1 ns
Malfunction: 10 to 55 Hz, 10 min each in X, Y, and Z directions; acceleration: 9.8 m/s
Destruction: 10 to 55 Hz, 30 min each in X, Y, and Z directions; acceleration: 19.6 m/s
Malfunction: Models with transistor outputs: 196 m/s
Models with relay contact outputs: 98 m/s
2
Destruction: 294 m/s
for 3 times each in X, Y, and Z directions
Operating:
10 C to 55 C (with no condensation or icing)
Storage:
25 C to 65 C (with no condensation or icing)
Operating:
25% to 85% (with no condensation)
(EMI)
Emission Enclosure:
Emission AC Mains:
(EMS)
Immunity ESD:
Immunity RF-interference:
Immunity Fast Transient Noise:
Immunity Burst Noise:
Immunity Surge:
Immunity Conducted Disturbance EN61000-4-6:
Immunity Voltage Dip/Interrupting EN61000-4-11:
UL508, CSA22.2;
Conforms to EN61326+A1, EN61010-1 (IEC61010-1)
Conforms to VDE0106/P100 (finger protection) when the terminal cover is mounted.
Approx. 100 g
K3GN
No communications
K3GN-NDC 24 VDC
K3GN-NDT1 24 VDC
K3GN-PDC 24 VDC
K3GN-PDT2 24 VDC
2
for 3 times each in X, Y, and Z directions
2
for 3 times each in X, Y, and Z directions
EN61326+A1
Industry
CISPR 11 Group 1 class A: CISRP16-1/-2
CISPR 11 Group 1 class A: CISRP16-1/-2
EN61326+A1
Industry
EN61000-4-2:
4 kV contact discharge (level 2)
8 kV air discharge (level 3)
EN61000-4-3:
10 V/m (amplitude-modulated,
80 MHz to 1 GHz) (level 3)
EN61000-4-4:
2 kV (power line) (level 3)
1 kV line to line (I/O signal line)
EN61000-4-5:
1 kV line to line
2 kV line to ground (power line)
3 V (0.15 to 80 MHz) (level 2)
0.5 cycles, 0, 180 , 100% (rated voltage)
Communications
RS-485
K3GN-NDC-FLK 24 VDC
K3GN-NDT1-FLK 24 VDC
K3GN-PDC-FLK 24 VDC
K3GN-PDT2-FLK 24 VDC
2
2