Uninterruptible Power Supply ADIRA LI RT 1000 VA – 3000 VA User Manual V 1.0 Item number: ACX11A1T1K0LI000 ACX11A1T2K0LI000 ACX11A1T3K0000LI English Operating Manual (translation)
Installation and connection of the UPS ..............32 External bypass ....................... 34 Connection preparations ..................34 Connecting the UPS device ..................35 Communication ..................... 40 Device operation and service ................45 Operation and performance of the UPS ..............45 ADIRA LI RT Series...
Page 4
Optional accessories ..................... 65 15.1 External battery bank and connection cable ............. 65 15.2 External bypass ....................... 65 15.3 Communication adapter SNMP ................66 15.4 Communication adapter, relay card (Z0C/AS400) ............ 66 Declaration of conformity..................67 ADIRA LI RT Series...
Please read this operating manual carefully and take particular note of the safety instructions! If you have questions about the device, the technical supervisor at your company or our employees will gladly assist you. Sincerely, EFFEKTA Regeltechnik GmbH ADIRA LI RT Series...
(UPS) defined in the technical data as a whole or as it refers to modules, components, and individual parts that were developed and built by EFFEKTA Regeltechnik GmbH ( Chapter 13 Technical data). Read this documentation carefully and familiarize yourself with the product before beginning with its operation.
Page 7
This symbol indicates text that contains notices or instructions/comments or advice. Warning about danger areas: General warning about danger areas! Specific warnings: ADIRA LI RT Series...
Page 8
Disconnect before operation! Environmental symbols: Indicates instructions for recycling. Indicates components that are subject to the Electronic Swap Regulation. Indicates components or parts that must be disposed of properly. Do not dispose of these in the household waste. ADIRA LI RT Series...
This applies, in particular, to maintenance, operating and cleaning personnel including persons responsible for transportation and/or disposal. EFFEKTA Regeltechnik GmbH is not liable for damage incurred or caused by staff who have not been trained or who have been insufficiently trained.
The warranty period for replaced and/or repaired parts as part of this warranty expires together with the original warranty for the product. ADIRA LI RT Series...
EFFEKTA Regeltechnik GmbH was informed of the possibility of such damage in advance. This exemption also includes any liability that can result from the claims of third parties against the initial purchaser.
The device is not designed for use: – in explosive; – in dusty or humid; – in radioactive or – in biological or chemically contaminated atmospheres! For information about the respective IP protection class of the device, please contact our service centers. ADIRA LI RT Series...
Observe the prescribed instruction steps. Use only original replacement parts from EFFEKTA Regeltechnik GmbH. Environmental protection Return the product to EFFEKTA Regeltechnik GmbH after the end of its service life. We will ensure that it is disposed of in an environmentally friendly manner.
4. Storage and unpacking Due to the possibility of existing energy storage (accumulators) within a UPS, devices must generally be inspected by EFFEKTA Regeltechnik GmbH or a qualified service center for transportation damages. Overall, transport damages present a high risk that the energy storage units and/or their electrical connections have been affected.
UPS; – Do not connect any loads or appliances to the UPS that could overload the device; – In general, only use appropriate tools for the installation. ADIRA LI RT Series...
Working with accumulators The UPS systems in the ADIRA LI RT series are equipped with lithium-ion batteries. When handling accumulators, there is always a risk of electric shock, burns and/or chemical burns.
The UPS may not be disassembled; – Work on the accumulators must only be carried out and supervised by personnel with the required expertise concerning safety regulations; – Unauthorized personnel are to be kept away from the UPS and the accumulators. ADIRA LI RT Series...
The ADIRA LI RT series contains an internal battery bank as well as a secondary power source. A possible extension of the autonomous times occurs through the adaption of an external battery bank or its capacity. If very high...
Page 19
In the event the supply network temporarily fails, the inverter draws power directly from the battery bank and thereby supplies the UPS output without interruption. The battery mode is limited by the capacity of the battery bank and its charging status. Fig. 3-3 Operating mode: battery mode. ADIRA LI RT Series...
Page 20
However, the use of the ECO MODE is only sensible when the loads are “robust” devices which have low tolerance for switching and power supply fluctuations while in the bypass mode. ADIRA LI RT Series...
Page 21
The same applies as long as the UPS is not being supplied by the public network but rather by a generator. ADIRA LI RT Series...
ADIRA LI RT 1000 VA – 3000 VA Device Description The device series, format and housing sizes The ADIRA LI RT series 1000VA-3000VA is produced in a wide range of performance capacities and models, each with a respective XL variant. See the following lists for more information.
Thus the respective rear sides of the ADIRA LI RT device series differ in individual models and are represented accordingly below with the numbered components: ADIRA LI RT 1000 ADIRA LI RT 2000 ADIRA LI RT 3000 ADIRA LI RT Series...
Page 24
Depending on the model, there are 6-8 plugs. The current carrying capacity is labelled accordingly. The device variants ADIRA LI RT 3000 is also equipped with a 16A high-current output. ADIRA LI RT Series...
Page 25
UPS with a (suitable) external battery bank. The nominal battery bank voltage is indicated directly on the connection and must be observed! The slot for additional expansion modules, INTELLIGENT SLOT (7), is usually fitted with an SNMP adapter. ADIRA LI RT Series...
Page 26
UPS. The representation of all device information and parameters occurs on the LC DISPLAY. This includes operation parameters, status data or error codes. A complete table of all status messages on all UPS operating modes is summarized under 9 Error diagnosis. ADIRA LI RT Series...
Page 27
The UPS normally operates in an online or high efficiency mode. green The UPS is in battery mode. orange The UPS is in bypass mode. yellow The UPS has an active alarm or error. See the chapter on “Error messages” for further information. ADIRA LI RT Series...
Page 28
The operating unit or LC display can be used to read the status and other information about the system or to set important parameters. Due to continuous updates of the software, it is possible that additional information exists that is not addressed here in detail. ADIRA LI RT Series...
Page 29
The UPS conducts a battery test. The UPS identifies defective batteries, Battery error or a battery connection has been disrupted. Some unnecessary loads should be Overload switched off to reduce the overall load. Several serious problems have Error mode occurred. ADIRA LI RT Series...
This way, the possibility of the device tipping over is ruled out; – There is always a general risk of tipping or tilting in the case of devices with a high center of gravity. ADIRA LI RT Series...
Instead, notify the supplier and dealer immediately. The packaging is recyclable. Please save these materials after unpacking for later use or dispose of them properly. Scope of delivery 4.4.1 Rack/Tower model ADIRA LI RT Series...
UPS, it is advantageous to keep some space between the UPS and the battery bank. The battery bank can also be installed below the UPS. When installing in superior systems (e.g. machines, facilities), it must be noted that the UPS and battery bank must be operated in ADIRA LI RT Series...
Page 33
Note: The UPS charges the battery once it is it connected to the power source even if the on/off button is not pressed. When the UPS is connected to the AC power source, 8 hours of charging time is necessary before the battery can supply the specified interim period. ADIRA LI RT Series...
Before beginning with the connection work, please pay attention to the safety instructions ( 2 Connection) for connecting all components included the power supply. In general, check that all connections have no present voltage before beginning further work. ADIRA LI RT Series...
Connecting the UPS device The ADIRA LI RT series is equipped with cold device connections in accordance with IEC 60320. In this way, the UPS can be connected to the common wall socket (mains power supply) with the power cable provided.
Page 36
Furthermore, the load(s) can usually be connected to the UPS with an appropriate cold device cable. Attention must also be paid here that the PE protection connection and the corresponding fuse for the loads are present. Fig. 5-1 Block diagram of the UPS series ADIRA LI RT ADIRA LI RT Series...
Page 37
The loads will continue to be supplied for the duration of the UPS autonomous time. The UPS device contains components carrying high voltage and current. Improper handling could therefore lead to electrical accidents with potentially fatal outcomes or property damage. ADIRA LI RT Series...
Page 38
ADIRA LI RT 1000 VA – 3000 VA Communication 5.3.1 Installation of the ADIRA LI RT model 5.3.1.1 Rack installation Carry out Steps 1 through 4 for installation on the 19”-rails. ADIRA LI RT Series...
Page 39
ADIRA LI RT 1000 VA – 3000 VA Communication 5.3.1.2 Tower installation ADIRA LI RT Series...
If an emergency off button or similar is not used, you must bridge the contact directly to the plug. Connection data Connection type max. 1 mm² cable Specification of the external switch 60 V DC/30 V AC 20 mA max. ADIRA LI RT Series...
Page 41
60 V DC/30 V AC 20 mA max. Relay contact (output) The output contact can be configured in the menu under “Settings.” Connection data Connection type max. 1 mm² cable Internal relay specification 24 V DC / 1A ADIRA LI RT Series...
Page 42
(UPS) and other devices with serial, USB, or network ports and receives status information and measurement data through these. ® This UPS management software can be downloaded for all EFFEKTA AC-UPS for free under the following link. https://www.generex.de/partners/oem/32 The following display then appears: You must select “Software solutions”...
Page 43
ADIRA LI RT 1000 VA – 3000 VA Communication In the following window, please select “UPSMAN installer”: In the new window, you can then select your operating system (e.g. Windows). Please note the license key required for the installation. ADIRA LI RT Series...
Page 44
After extracting the zip file, you will have the following files: With the application “upsmaninstaller,” the installation is started and the UPS management software UPSMAN is installed. Enter the noted license key here. ADIRA LI RT Series...
– Switching from standard operating mode to autonomous mode and vice versa. The operation of the UPS or system generally assumes that all previous chapters in this operating manual have already been successfully handled and monitored. ADIRA LI RT Series...
Page 46
The switching on procedure is now completed. The UPS or system can remain in this state. The loads must possibly still be switched on. The start process or switching to a different operating mode can take a few seconds under circumstances as internal synchronization processes are occurring. ADIRA LI RT Series...
Page 47
The UPS device can also be started directly in the autonomous mode when a mains power supply is not available. Follow the instructions below for this: ✓ To begin, the device is completely switched off. There is no mains power supply! ADIRA LI RT Series...
Page 48
(LOAD) in the display here. Do not leave the device or system in this state. Either switch the device off or ensure that the mains power supply is present and the device switches to standard mode. ADIRA LI RT Series...
Reset to the factory settings Settings See Chapter 7.2.1 User settings [Product name], [Serial number], [Firmware Identification version], [IP/MAC address] 7.2.1 User settings Submenu Available settings Standard settings English, Italiano, Français, Deutsch, Español, Language English Русский, Polski, 简体中文 ADIRA LI RT Series...
Page 50
[Battery disconnected] occurs (default setting) (default setting) UPS outputs normally in [Bypass output] bypass mode The UPS does not have [UPS normal] any alarms or failures Ambient temp. alarm [activated], [not active] activated ADIRA LI RT Series...
Page 51
Device operation Submenu Available settings Standard settings Duration of battery test [activated], [not active] activated 01/01/2020 00:00 Date/time dd/mm/yyyy, hh:mm LCD contrast [-5 ~ +5] Modbus TCP [activated], [not active] not active [activated], [not active] not active ADIRA LI RT Series...
UPS; • Follow the order in reverse to shut down the UPS. In the event that errors occur during the initial operation, these must first be analyzed and eliminated before the initial operation can be continued. ADIRA LI RT Series...
Start a new battery test: If connected batteries, or the problem is still present, contact LED is on. the minimum voltage of your customer service agent. Continuous beep. the battery is achieved in the OBM cycle mode. ADIRA LI RT Series...
Page 54
1. Check the status of the RPO connection. Reset the RPO error on the LCD display. Reset the main menu – management – error status. Ventilation error Ventilation is abnormal. Check if the fan is operating normally. ADIRA LI RT Series...
Page 55
The IP address of the UPS is entered in correct. the PC browser. Default username/password: admin/Admin*1 Never attempt to start the UPS when there is an error status. First eliminate the error source and then switch the device on again. ADIRA LI RT Series...
0049 / (0) 741 – 17451-52 Telephone: You can also reach us via email at: kundendienst@effekta.com In addition, you can contact the relevant department or branch office directly as listed on our website: http://www.effekta.com ADIRA LI RT Series...
This means that the UPS must operate in the standard operating mode for several hours (min. 6 h) to recharge the battery bank accordingly before this is approximately 80% operational (capable of supporting loads) again. ADIRA LI RT Series...
Page 58
Always observe the safety guidelines for live-line working. In general, the devices of the ADIRA LI RT series are capable of a HOT SWAP. This means that the battery modules and the additional battery banks can be replaced in the operating UPS.
Page 59
Please perform the work for the battery module replacement in the following order 1-4. To replace the battery module, only access to the front panel of the UPS is required: ADIRA LI RT Series...
Page 60
Return the battery bank to us in the same packaging in which you received the new battery bank or take it to an appropriate recycling center. The assembly essentially follows the reverse order here as well. ADIRA LI RT Series...
Maintenance and Service 12.3 Maintenance and service contracts EFFEKTA Regeltechnik GmbH offers corresponding maintenance and service contracts to guarantee the best possible reliability and availability of the UPS. Under a maintenance contract, our service personnel can also support and assist you in the following areas: Regular inspection of the UPS, in particular, the accumulators and their timely replacement.
1 x for optional SNMP or relay card Display LCD-display and LED-displays USV (HxWxD in mm) 85,5(2HE) x 85,5(2HE) x 438 x 600 Measurements / 438 x 445 Weights Weight in kg 14,95 21,1 21,45 Protection class IP20 ADIRA LI RT Series...
Page 63
0-40° C (at 80% load up to 45° C) Ambient conditions Humidity 20~90% (non-condensing) Operation noise <45 dB, 1 m <50 dB, 1 m Safety IEC/EN62040-1, UN38.3 Schutz/Normen IEC/EN62040-2 class C2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5 Certificates ADIRA LI RT Series...
Type of plug: Type A, in accordance with type B RS232 cable (1:1) Serial EPO plug with bridge, screwable Software (download link) Software Chapter 6.4 UPS Management Software Operating manual English Operating manual translation from German V 1.1 ADIRA LI RT Series...
ADIRA LI RT 1000 VA – 3000 VA Optional accessories Optional accessories The components, devices, and/or equipment listed below are accessories that are suitable for the ADIRA LI RT series and have been tested and approved by EFFEKTA Regeltechnik GmbH. 15.1 External battery bank and connection cable Every UPS device requires an energy storage unit to supply the loads with its stored energy during a power failure.
The relay card also belongs to the intelligent extension cards and is used in the direct and potential-free coupling with external management and/or machines. This allows the UPS status to be transferred to superordinate controls in real time. Fig. 155-4 Relay card AS400 for real time control of the UPS. ADIRA LI RT Series...
Declaration of conformity Units labelled with a CE mark fulfill the EU harmonized standards and regulations. The EU declaration of conformity for this product is available upon request. Please contact our Chapter 11 Service-Hotline ADIRA LI RT Series...
Need help?
Do you have a question about the ADIRA LI RT Series and is the answer not in the manual?
Questions and answers