Ratings And Specifications - Omron E3X-SD Datasheet

Easy-teach digital fiber amplifier
Hide thumbs Also See for E3X-SD:
Table of Contents

Advertisement

Ratings and Specifications

Amplifier Units
Item
Light source (wavelength) Red, 4-element LED (625 nm)
12 to 24 VDC 10%, ripple (p-p): 10% max.
Power supply voltage
Power consumption/
960 mW max. (Power supply voltage: 24 V,
Current consumption
Current consumption: 40 mA max.) (Power supply voltage: 12 V, Current consumption: 80 mA max.)
Open-collector output (NPN or PNP) Load power supply: 26.4 V max., Load current: 50 mA max. (Residual voltage: 1.5 V max.)
Control output
Light-ON/Dark-ON mode selector
Operate or reset: 200 s max.
Response time
Sensitivity adjustment
UP/DOWN direct key setting, teaching with/without a workpiece, automatic teaching
Protection circuits
Power supply reverse polarity protection, output short-circuit protection, output reverse polarity protection
Mutual interference
Up to 5 Amplifiers (optically synchronized)
prevention
Receiver side
Ambient illumination
Incandescent lamp: 10,000 lux max.
Sunlight: 20,000 lux max.
Number of gang-mounted
16 max. (The ambient temperature specification depends on the number of gang-mounted Amplifiers.)
Amplifiers
Operating: Groups of 1 to 3 Amplifiers:
Ambient temperature
range
Storage:
Ambient humidity range
Operating and storage: 35% to 85% (with no condensation)
Insulation resistance
20 M. min. (at 500 VDC)
Dielectric strength
1,000 VAC at 50/60 Hz for 1 minute
Vibration resistance
Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance
Destruction: 500 m/s
Degree of protection
IEC 60529 IP50 (with Protective Cover attached)
Connection method
Pre-wired (standard cable length: 2 m), or connector
Weight (packed state)
Pre-wired model: Approx. 100 g, Model with connector: Approx. 55 g
Case
Polybutylene terephthalate (PBT)
Material
Cover
Polycarbonate (PC)
Accessories
Instruction manual
*1.
Mutual interference prevention is effective when E3X-SD-series Amplifiers are gang-mounted without other E3X-series Amplifiers.
2
*1
25C to 55C
25C to 50C
Groups of 4 to 11 Amplifiers:
25C to 45C
Groups of 12 to 16 Amplifiers:
30C to 70C (with no icing or condensation)
2
, for 3 times each in X, Y and Z directions
E3X-SD@
Easy teach fiber amplifier

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents