Ratings and Specifications

Item
Sensing distance
Directional angle
Light source (wavelength)
Power supply voltage
Current consumption
Control output
Operating modes
Protective circuits
Response time
Sensitivity adjustment
Ambient illumination
Ambient temperature range
Ambient humidity range
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Indicator
Weight
Materials
Housing
Lens
Cable
Accessories
*1.
IP69K is a protection standard against high temperature and high-pressure water defined in the German standard DIN 40050,
Part 9. The test piece is sprayed with water at 80°C at a water pressure of 80 to 100 BAR using a specified nozzle shape at a
rate of 14 to 16 liters/min.
The distance between the test piece and nozzle is 10 to 15 cm, and water is sprayed horizontally for 30 seconds each at 0°, 30°,
60°, and 90° while rotating the test piece on a horizontal plane.
*2
For reflectors and mounting brackets refer to Accessories.

Engineering Data (Typical)

Parallel Operating Range

E3FZ-B
30
20
E39-RS2
10
0
-10
E39-RS2
-20
-30
-40
0
200
400
600
800
On-Point (right)
On-Point (left)
E3FZ-B
E3FZ-B_
0 to 700 mm (Using E39-R1S, other reflectors see diagram operating range)
Sensor: 3° to 10°
Reflector: 30° max.
Red LED (650 nm)
10 to 30 VDC, including 10% ripple (p-p)
25 mA max.
Load power supply voltage: 30 VDC max., Load current: 100 mA max. (Residual voltage: 2 V max.)
Open-collector output (NPN/PNP output depending on model)
Light-ON/Dark-ON selectable by wire
Reversed power supply polarity, load short-circuit protection, mutual interference prevention, reversed
output polarity protection
Operation or reset: 1 ms max.
one-turn adjuster
Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max.
Operating: −25 to 55°C, Storage: −40 to 70°C (with no icing or condensation)
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)
20 MΩ min. at 500 VDC
1,000 VAC, 50/60 Hz for 1 min
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
2
Destruction: 500 m/s
3 times each in X, Y, and Z directions
IEC 60529: IP67, DIN 40050-9: IP69K
Pre-wired cable (standard length: 2 m) or M12 4-pin connector
Operating indicator (yellow), Stability indicator (green)
Pre-wired models: Approx. 60 g
Connector models: Approx. 20 g
ABS
PMMA (polymethylmethacrylate)
PVC (polyvinyl chloride)
Instruction sheet, 2x M18 nuts
Excess Gain vs. Distance
E3FZ-B
100
E39-R1S
10
1
E39-R1S
0.1
0
1000
1200
1400
Distance (mm)
*1
*2
E39-RS2
E39-R1-S
0.5
1
1.5
Sensing distance (m)
2
3