E3ZM-V

Ratings and Specifications

Sensing method
Model
NPN output
Item
PNP output
Sensing distance
Sensing range
Spot diameter
Light source (wavelength) White LED (450 to 700 nm)
Power supply voltage
Power consumption
Control output
Remote control input
Operating modes
Protection circuits
Response time
Sensitivity adjustment
Ambient illumination
Ambient temperature
range
Ambient humidity range
Insulation resistance
Dielectric strength
Vibration resistance
(destruction)
Shock resistance
(destruction)
Degree of protection
Connection method
Indicator
Weight (packed state)
Housing
Lens
Materials
Indication
Buttons
Cable
Accessories
*1. A deviation of ±2 mm (typical value) can be handled for combinations of
white, yellow, and black. Refer to page 7 for the detection capabilities for
other colors.
*2. Mark Sensor output switching:
When teaching, specify the ON color first and the OFF color second.
*3. Do not bend the cable in temperatures of −25°C or lower.
6
12±2 mm *1
Depends on the combination of colors. Refer to Engineering Data on page 7 for details.
2-mm dia. max.
10 to 30 VDC, including 10% ripple (p-p)
600 mW max. (current consumption for a 30-V power supply voltage: 20 mA max.)
Load power supply voltage: 30 VDC max., Load current: 100 mA max. (Residual voltage: 2 V max.)
Open-collector output (NPN/PNP output depending on model)
NPN output ON: Short-circuit to 0 V, or 1.5 V max. (source current: 1 mA max.)
NPN output OFF: Open or Vcc −1.5 V to Vcc (leakage current: 0.1 mA max.)
PNP output ON: Vcc −1.5 V to Vcc (sink current: 1 mA max.)
PNP output OFF: Open or 1.5 V max. (leakage current: 0.1 mA max.)
Set in the order of the teaching operation. *2
Reversed power supply polarity, Load short-circuit protection, and Reversed output polarity protection
Operate or reset: 50 μs max.
Teaching method
(Receiver side) Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max.
Operating: −40 to 60°C (*3), Storage: −40 to 70°C (with no icing or condensation)
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)
20 MΩ min. (at 500 VDC)
1,000 VAC at 50/60 Hz for 1 min
10 to 55 Hz, 1.5-mm double amplitude for 2 h each in X, Y, and Z directions
2
500 m/s
for 3 times each in X, Y, and Z directions
IEC 60529: IP67, DIN 40050-9: IP69K
Pre-wired cable (standard length: 2 m) or M8 4-pin connector
Operating indicator (yellow), Stability indicator (green), and Teaching indicator (red)
Pre-wired models (2-m cable): Approx. 85 g
Connector models: Approx. 35 g
SUS316L
PMMA (polymethylmethacrylate)
PES (polyethersulfone)
Fluoro rubber
PVC (polyvinyl chloride)
Instruction sheet Note: Mounting Brackets are purchased separately.
Diffuse reflective (mark detection)
E3ZM-V61/-V66
E3ZM-V81/-V86
Standard Sensing Object for the Mark Sensor
Color
White
Red
Yellow-red
Yellow
Yellow-green
Green
Blue-green
Blue
(Black)
Munsell color notation
N9.5
4R 4.5/12.0
4YR 6.0/11.5
5Y 8.5/11.0
3GY 6.5/10.0
3G 6.5/9.0
5BG 4.5/10.0
3PB 5.0/10.0