Ratings And Specifications - Omron TL-N Series Quick Start Manual

Rectangular standard proximity sensor
Table of Contents

Advertisement

Accessories (Order Separately)
Mounting Brackets
Type
Mounting Brackets
Mounting Brackets for Conduits

Ratings and Specifications

DC 2-Wire Models
Item
Model
Sensing distance
5 mm 10%
Set distance
0 to 4 mm
Differential travel
10% max. of sensing distance
Detectable object
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 5.)
Standard sensing
Iron, 18
object
Response
500 Hz
frequency
*
Power supply voltage
(operating voltage
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
range)
Leakage current
0.8 mA max.
Load
3 to 100 mA
current
Control
output
Residual
3.3 V max. (Load current: 100 mA, Cable length: 2 m)
voltage
D1 Models: Operation indicator (red), Setting indicator (green)
Indicators
D2 Models: Operation indicator (red)
Operation mode
D1 Models: NO
(with sensing object
D2 Models: NC
approaching)
Protection circuits
Load short-circuit protection, Surge suppressor
Ambient
Operating/Storage: 25 to 70 C (with no icing or condensation)
temperature range
Ambient
Operating/Storage: 35% to 95% (with no condensation)
humidity range
Temperature influence
10% max. of sensing distance at 23 C in the temperature range of 25 to 70 C
Voltage influence
2.5% max. of sensing distance at rated voltage in the rated voltage 15% range
Insulation resistance
50 M min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
1,000 VAC for 1 min between current-carrying parts and case
Vibration
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
resistance
Destruction: 500 m/s
Shock resistance
each in X, Y, and Z directions
Degree of protection
IEC 60529 IP67, in-house standards: oil-resistant
Connection method
Pre-wired Models (Standard cable length: 2 m)
Weight (packed state)
Approx. 45 g
Case
Materials
Heat-resistant ABS
Sensing
surface
Accessories
Instruction manual
* The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
http://www.ia.omron.com/
Model
Provided with these Sensors
Y92E-C5
TL-N5ME@, TL-N7MD@
Y92E-C10
TL-N10ME@, TL-N12MD@
Y92E-C20
TL-N20ME@, TL-N20MD@
Y92E-N5C15
Y92E-N10C15
TL-Q5MD@
TL-N7MD@
7 mm 10%
0 to 5.6 mm
18
1 mm
Iron, 30
30
Refer to the timing charts under I/O Circuit Diagrams on page 7 for details.
2
3 times
Destruction: 1,000 m/s
Approx. 145 g
Mounting Bracket, Instruction manual
Applicable Sensors
TL-N5MY@
TL-N10MY@
TL-N20MY@
---
TL-N5ME@, TL-N5MY@
---
TL-N10ME@, TL-N10MY@
TL-N12MD@
12 mm 10%
0 to 9.6 mm
1 mm
Iron, 40
40
1 mm
2
10 times each in X, Y, and Z directions
Approx. 170 g
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
TL-N/TL-Q/TL-G
Order separately
TL-N20MD@
20 mm 10%
0 to 16 mm
Iron, 50
50
1 mm
300 Hz
Approx. 240 g
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents