Page 1
2,0 mm E2EL-C2E1-DS 2M E2EL-C2E2-DS 2M E2EL-C2F1-DS 2M E2EL-C2F2-DS 2M Ø 45 mm Shielded 2,0 mm E2EL-C2E1-DSL 2M E2EL-C2E2-DSL 2M E2EL-C2F1-DSL 2M E2EL-C2F2-DSL 2M 30 mm Shielded 2,0 mm E2EL-X2E1-DS 2M E2EL-X2E2-DS 2M E2EL-X2F1-DS 2M E2EL-X2F2-DS 2M 45 mm Shielded...
Page 2
Operating: -25° to 70°C Humidity 35 to 95 % RH Influence of temperature ± 10 % max. of Sn at 23°C in temperature range of -25° to 70°C 1.500 VAC, 50/60 Hz for 1 min. between current carry parts and Dielectric strength case...
Page 3
1.500 VAC, 50/60 Hz for 1 min. between current carry parts and case Electromagnetic compatibility EMC EN 60947-5-2 Destruction: 10 to 70 Hz, 1,5 mm double amplitude for 1 hour each in X, Y Vibration resistance and Z directions Shock resistance Destruction: 300 m/s²...
Page 4
'switch-on' curve ' switch-off' curve lateral approach -0,8 -0,6 -0,4 -0,2 lateral distance related to radius of 'active surface' (r/r Output Circuit Diagram and Timing Chart E2EL-@E@ E2EL-@F@ NPN Output PNP Output Brown 1 Brown 1 Load...
Page 7
Wiring through Metal Conduit Power Reset Time If there is a power or high-tension line near the cord of the Prox- The Proximity Sensor is ready to operate within 100 ms after imity Sensor, wire the cord through an independent metal conduit power is supplied.
Page 8
Fig.2: Shielded SUS type ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. D06E-EN-01 In the interest of product improvement, specifications are subject to change without notice.