Page 1
High quality for extra long life in daily use • wide portfolio range through modular concept • designed and tested for extra long life • IP67 and IP69k for highest protection in wet environments • continuously high quality level through specialized manufacturing process •...
Page 3
E2A-M30LN30-M3-C1 E2A-M30LN30-M3-C2 n.a. *1. Material specifications for stainless steel housing case: 1.4305 (W.-No.), SUS 303 (AISI), 2346 (SS). Please contact your OMRON representative for other stainless steel materials. *2. Please contact your OMRON representative for DC 2-wire models. *3. Stainless steel models are also available. Please contact your OMRON representative.
Page 4
Connectivity The E2A sensors are available with the following connectors and cable materials: Pre-wired models Pre-wired models with cable end connectors Standard cable lengths are 2m and 5m. All pre-wired models can be fitted with cable and connectors. For other cable lengths please contact your OMRON Standard cable end connectors: representative.
2. When using any model at an ambient temperature between − 40°C and − 25°C and a power voltage between 30 and 32 VDC, use a load current of 100 mA max.,...
Page 7
2. When using any model at an ambient temperature between − 40°C and − 25°C and a power voltage between 30 and 32 VDC, use a load current of 100 mA max.
Page 8
2. When using any model at an ambient temperature between − 40°C and − 25°C and a power voltage between 30 and 32 VDC, use a load current of 50 mA max.
Page 9
2. When using any model at an ambient temperature between -40°C and -25°C and a power voltage between 30 and 32 VDC, use a load current of 50 mA max.
E2A-M08@S02 E2A-S08@N04/ E2A-M08@N04 −50 −40 −30 −20 −10 −30 −20 −10 Distance Y (mm) Distance Y (mm) Influence of Sensing Object Size and Materials Shielded Models E2A-S08@S02 E2A-M12@S04/ E2A-S12@S04 E2A-M18@S08/E2A-S18@S08 Iron t = 1 mm t = 1 mm Iron...
Page 11
Brass Brass Aluminum Aluminum Aluminum Copper Copper Copper Side length of sensing object d (mm) Side length of sensing object d (mm) Side length of sensing object d (mm) E2A-M30LN30/E2A-S30LN30 E2A-M30KN20/E2A-S30KN20 t = 1 mm Iron t = 1 mm...
M8 Connector Pin Arrangement (3 pin) (4 pin) (See note 2.) Pin Arrangement Pin Arrangement (See note 2.) Note 2: Pin 2 of the M12 connector and M8 connector is not used. Non-sensing zone Sensing zone Brown Sensing object Black...
Page 13
M8 connector (4 pin) (3 pin) Pin Arrangement Pin Arrangement Pin Arrangement (See note 2.) (See note 2.) Note 2: Pin 2 of the M12 connector and M8 connector is not used. Non-sensing zone Sensing zone Brown Sensing object Load Proximity (See note 1.)
Page 14
Timing chart Output circuit Non-sensing zone Sensing zone Brown Load Sensing object E2A-@-D1 Blue Yellow indicator Load can be connected to +V or 0V side. Red indicator M12 Connector Control output Pin Arrangement Non-sensing zone Sensing zone Brown Load Sensing object...
Page 15
; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) 2. Operation indicator (yellow) 3. for NO+NC (-B3 / -C3) models the total length is 4 mm longer 3. for NO+NC (-B3 / -C3) models the total length is 4 mm longer E2A-M18KS08-WP-@@/E2A-S18KS08-WP-@ E2A-M18KN16-WP-@@/E2A-S18KN16-WP-@ 59.5...
Page 16
M8×1 Two, clamping nuts Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm ; insulator diameter: 1.3 mm); standard length: 2 m 0.3 mm...
Page 17
Two, clamping nuts Note 1: Operation indicator (yellow LED, 4×90°) Note 1: Operation indicator (yellow LED, 4×90°) Note 2: for NO+NC (-B3 / -C3) models the total Note 2: for NO+NC (-B3 / -C3) models the total length is 4 mm longer...
Precautions Safety Precautions Wiring Power Supply Be sure to wire the E2A and load correctly, otherwise it may be dam- aged. Do not impose an excessive voltage on the E2A, otherwise it may be Connection with No Load damaged. Do not impose AC current (100 to 240 VAC) on any DC model, otherwise it may be damaged.
180 Nm <SUITABILITY FOR USE> OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the customer’s application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used.