Specifications - Omron A22E Datasheet

Emergency stop switch
Hide thumbs Also See for A22E:
Table of Contents

Advertisement

Specifications

Approved Standards
Recognized
Standards
organization
UL (See note.)
UL508
AZCO
EN60947-5-1
Note: UL-approved for CSA C22.2 No. 14 and bears the
Approved Standard Ratings
• UL, cUL (File No. E41515)
6 A at 220 V, 10 A at 110 VAC
• EN60947-5-1 (Low Voltage Directive)
Rated current: 10 A; Rated voltage: 220 VAC
Ratings
Contacts (Standard Load)
Rated
Rated
AC15
carry
voltage
(induc-
current
tive load)
24 VAC
10
110 VAC
5
220 VAC
3
380 VAC
2
10
440 VAC
1
24 VDC
110 VDC
---
220 VDC
380 VDC
Note: 1. Rated current values are determined according to the test-
ing conditions. The above ratings were obtained by con-
ducting tests under the following conditions.
(1) Ambient temperature: 20×±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 20 operations/minute
2. Minimum applicable load: 10 mA at 5 VDC
Contacts (Microload)
Rated applicable load
50 mA at 5 VDC
(Resistive load)
G-310
File No.
E41515
C9805502
R mark.
c
Rated current (A)
AC12
DC13
DC12
(resistive
(induc-
(resis-
load)
tive load)
tive load)
10
10
6
---
---
3
2
1.5
10
0.5
2
---
0.2
0.6
0.1
0.2
Minimum applicable load
1 mA at 5 VDC
LED Indicators without Voltage Reduction Unit
Rated voltage
Rated current
6 VDC
60 mA
6 VAC
60 mA
12 VAC/VDC
30 mA
24 VAC/VDC
15 mA
Super-bright LED Indicator
Rated voltage
Rated current
24 VAC/VDC
15 mA
Incandescent Lamp
Rated voltage
Rated current
6 VAC/VDC
200 mA
14 VAC/VDC
80 mA
28 VAC/VDC
40 mA
130 VAC/VDC
20 mA
Voltage-reduction Lighting
Rated voltage
Operational voltage
110 VAC
95 to 115 VAC
220 VAC
190 to 230 VAC
Safety Sensors / Components
Operating voltage
6 VDC±5%
6 VAC/VDC±5%
12 VAC/VDC±5%
24 VAC/VDC±5%
Operating voltage
24 VAC/VDC ±5%
Operating voltage
5 VAC/VDC
12 VAC/VDC
24 VAC/VDC
100 VAC/VDC
Applicable lamp
(BA9S/13# gold)
LED Lamp
(A22-24A#)

Advertisement

Table of Contents
loading