Dentsply Sirona Xios XG Operating Instructions And Installation

Dentsply Sirona Xios XG Operating Instructions And Installation

Usb module and sensors
Hide thumbs Also See for Xios XG:
Table of Contents

Advertisement

Quick Links

2023-02
New as of:
Xios XG USB Module and
Sensors
Operating Instructions and Installation
English

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Xios XG and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dentsply Sirona Xios XG

  • Page 1 2023-02 New as of: Xios XG USB Module and Sensors Operating Instructions and Installation English...
  • Page 2: Table Of Contents

    2.12 Radiotelephones ......................2.13 Electrostatic discharge ....................System description ..................System setup [Xios XG with Xios XG USB module]............ System setup [Xios XG with Xios dentist unit USB module] ........USB module ........................ USB cable ........................Sensors ........................Sensor holder systems....................
  • Page 3 Dentsply Sirona Table of contents Operating Instructions and Installation Xios XG USB Module and Sensors 3.11 Certification, registration and standards..............3.12 Symbols........................3.13 Position of the labels ....................Installation ....................... Fitting a second protective ground conductor on the PC ..........
  • Page 4 Table of contents Dentsply Sirona Operating Instructions and Installation Xios XG USB Module and Sensors 5.8.1.3 Anterior tooth exposure ............... 5.8.1.4 Posterior tooth exposures............5.8.1.5 Bite wing exposures..............5.8.1.6 Endodontics exposures with the half-angle technique ....5.8.1.7 Measurement exposure for endodontics ........
  • Page 5 Dentsply Sirona Table of contents Operating Instructions and Installation Xios XG USB Module and Sensors Maintenance and inspection................100 Hygiene ........................100 9.1.1 Care, cleaning agents, and disinfectants ............100 9.1.2 USB module, WiFi interface and sensors ............. 100 Sensor holders....................102 9.1.3...
  • Page 6: General Information

    Xios XG can be operated with two types of sensor – the Xios XG Select and Xios XG Supremesensors. Both types of sensor are available in three sizes (0, 1 and 2). When using Xios XG Supreme sensors, enhanced image processing functions are available to you in Sidexis 4 / SIDEXIS XG through special filters.
  • Page 7: Contact Information

    Dentsply Sirona 1 General information Operating Instructions and Installation Xios XG USB Module and Sensors 1.2 Contact information Contact information Dentsply Sirona Product service Log in to register your units and make service requests: https://dentsplysirona.service-pacemaker.com/ Authorized agent in the EU...
  • Page 8: General Information About This Operating Manual

    1 General information Dentsply Sirona 1.3 General information about this operating manual Operating Instructions and Installation Xios XG USB Module and Sensors General information about this operating manual Follow the instructions for use Please familiarize yourself with the unit by reading through these instructions for use before putting it into operation.
  • Page 9: Intended Use

    Operating Instructions and Installation Xios XG USB Module and Sensors 1.5 Intended use Intended use The Xios XG X-ray system is designed for digital acquisition of intraoral X-ray images for diagnostic purposes. The system is used on patients by dental professionals. The digital images produced are transferred to a PC and displayed on a monitor.
  • Page 10: Structure Of The Document

    1 General information Dentsply Sirona 1.8 Structure of the document Operating Instructions and Installation Xios XG USB Module and Sensors Structure of the document 1.8.1 Identification of danger levels To prevent personal injury and material damage, please observe the warning and safety information provided in these operating instructions.
  • Page 11: Safety Instructions

    Do not use single use devices more than once. The sterilizable exposure accessories such as the rods and rings of the Xios XG sensor holder must be sterilized to prevent any possible transmission of infective agents which might under certain circumstances cause serious illnesses.
  • Page 12: Trouble-Free Operation

    2 Safety instructions Dentsply Sirona 2.6 Trouble-free operation Operating Instructions and Installation Xios XG USB Module and Sensors allocation of the X-rays to the patient data stored by Sidexis 4 / SIDEXIS XG. Trouble-free operation This unit may only be used in proper working condition. If trouble-free operation cannot be ensured, e.g., due to malfunctions, noticeable or...
  • Page 13: Modifications And Extensions Of The System

    Dentsply Sirona 2 Safety instructions Operating Instructions and Installation Xios XG USB Module and Sensors 2.10 Modifications and extensions of the system 2.10 Modifications and extensions of the system Modifications to this system which might affect the safety of the system owner, patients or other persons are prohibited by law.
  • Page 14 2 Safety instructions Dentsply Sirona 2.13 Electrostatic discharge Operating Instructions and Installation Xios XG USB Module and Sensors Areas at risk are indicated on the unit with the ESD warning label: We recommend that all persons working with this system are made aware of the significance of the ESD warning label.
  • Page 15: System Description

    Dentsply Sirona 3 System description Operating Instructions and Installation Xios XG USB Module and Sensors 3.1 System setup [Xios XG with Xios XG USB module] System description System setup [Xios XG with Xios XG USB module] USB module  [→ 17] USB cable  [→ 17] Sensor (size 0, 1 or 2) with cable and plug ...
  • Page 16: System Setup [Xios Xg With Xios Dentist Unit Usb Module]

    3 System description Dentsply Sirona 3.2 System setup [Xios XG with Xios dentist unit USB module] Operating Instructions and Installation Xios XG USB Module and Sensors SIDEXIS PC  [→ 22] with ● USB interface ● Sidexis 4 / SIDEXIS XG (SIDEXIS XG version 2.56 or higher) and Xios XG plugin ●...
  • Page 17: Usb Module

    PC via the USB module and USB cable. Further information can be found in the "Operation" section. The Xios XG Supreme sensors can be operated either with a Xios XG USB module or a Xios dentist element USB module. When using a Xios XG USB module, the USB cable is compatible with the USB 2 ports on a PC workstation.
  • Page 18: Sensors

    Operating Instructions and Installation Xios XG USB Module and Sensors Sensors Xios XG can be operated with two types of sensor – the Xios XG Select and Xios XG Supreme sensors. Both sensor types are available in three sizes (0, 1 and 2). Additionally, Xios XG Supreme sensors can be connected to either a standard USB 2 module or to the Xios dentist element USB module.
  • Page 19: Sensor Holder Systems

    Dentsply Sirona 3 System description Operating Instructions and Installation Xios XG USB Module and Sensors 3.6 Sensor holder systems Sensor holder systems 3.6.1 Single-use sensor holder system There are different sensor holders available depending on the type of exposure. The localizer rings and sensor holder tabs are color-coded.
  • Page 20 3 System description Dentsply Sirona 3.6 Sensor holder systems Operating Instructions and Installation Xios XG USB Module and Sensors Localizer ring Sensor holder for posterior tooth exposures right upper jaw / left lower jaw, yellow Sensor holder for bite wing exposures, red...
  • Page 21: Intraoral X-Ray Tube Assembly

    Dentsply Sirona 3 System description Operating Instructions and Installation Xios XG USB Module and Sensors 3.7 Intraoral X-ray tube assembly Intraoral X-ray tube assembly The following requirements apply to the intraoral X-ray tube assembly: Intraoral X-ray tube assembly with multipulse technology (direct current) 0.14 –...
  • Page 22: Pc System

    The digital X-ray exposures are transferred to a PC via a USB port. In addition to Sidexis 4 / SIDEXIS XG (SIDEXIS XG version 2.56 and above), the Xios XG Plugin must be installed. Information on the PC software can be found in the "SIDEXIS Plug-in for Xios XG Operator's Manual".
  • Page 23: Usb Hub (Optional)

    Dentsply Sirona 3 System description Operating Instructions and Installation Xios XG USB Module and Sensors 3.9 USB hub (optional) USB hub (optional) A USB module can be connected to the USB port of a PC either directly or via an active USB hub. An active USB hub is only required if there is inadequate power supply via the USB port of the PC.
  • Page 24: Technical Data

    3 System description Dentsply Sirona 3.10 Technical data Operating Instructions and Installation Xios XG USB Module and Sensors 3.10 Technical data USB module Protection class: Protection class II Type of protection against electric shock: Applied part type BF Degree of protection...
  • Page 25: Certification, Registration And Standards

    Operating altitude: ≤ 2000 m 3.11 Certification, registration and standards The Xios XG USB system complies with the following standards, among others. It complies with the requirements specified therein: EMC / Safety ● IEC 60601-1 (Medical electrical equipment – Part 1: General requirements for safety) ●...
  • Page 26: Symbols

    3 System description Dentsply Sirona 3.12 Symbols Operating Instructions and Installation Xios XG USB Module and Sensors 3.12 Symbols Unit with protection class II in accordance with IEC 60601-1 Type BF applied part according to IEC 60601-1 This symbol indicates the need for the user to consult the instructions for use before using the unit.
  • Page 27: Position Of The Labels

    Operating Instructions and Installation Xios XG USB Module and Sensors 3.13 Position of the labels 3.13 Position of the labels The following labels are attached to components of the Xios XG USB system: Xios XG USB module Xios dentist element USB module...
  • Page 28: Installation

    4 Installation Dentsply Sirona 4.1 Fitting a second protective ground conductor on the PC Operating Instructions and Installation Xios XG USB Module and Sensors Installation Fitting a second protective ground conductor on the PC Depending on whether the PC is operated inside or outside of the patient environment (up to 1.5 m around the patient), an additional...
  • Page 29 Dentsply Sirona 4 Installation Operating Instructions and Installation Xios XG USB Module and Sensors 4.1 Fitting a second protective ground conductor on the PC environment (A). This applies to all possible patient positions (B) during the examination or treatment. Version: PC located outside the patient environment CAUTION The PC must not then be moved closer to the patient.
  • Page 30 Dentsply Sirona 4.1 Fitting a second protective ground conductor on the PC Operating Instructions and Installation Xios XG USB Module and Sensors 6. Fasten the M4 connecting screw to the PC casing firmly with a toothed lock washer and nut.
  • Page 31: Install The Pc Software

    NOTE Refer to the following section if you are using Sidexis XG (version 2.56 or higher) and the Xios XG Plugin. For Sidexis 4 and the Sidexis 4 Sensor Plugin, please refer to the next section. The PC must be in a state of operational readiness before the installation of the Xios XG Intraoral System.
  • Page 32 Operating Instructions and Installation Xios XG USB Module and Sensors 5. Follow the additional instructions. 6. Restart the PC if you are required to do so. Ä The SIDEXIS plugin for Xios XG USB system is installed. 64 09 713 D3610 D3610.201.01.14.02    2023-02...
  • Page 33: Install The Pc Software [Sidexis 4 Sensor Plugin]

    Dentsply Sirona 4 Installation Operating Instructions and Installation Xios XG USB Module and Sensors 4.3 Install the PC software [Sidexis 4 Sensor Plugin] Install the PC software [Sidexis 4 Sensor Plugin] The Sidexis 4 sensor plugin must be installed in addition to Sidexis 4.
  • Page 34: Installing Intraoral Sensor Software For Usb And Wifi Devices

    4 Installation Dentsply Sirona 4.4 Installing Intraoral Sensor Software for USB and WiFi devices Operating Instructions and Installation Xios XG USB Module and Sensors Ä The Sidexis 4 sensor plugin is installed. Installing Intraoral Sensor Software for USB and WiFi devices...
  • Page 35 Dentsply Sirona 4 Installation Operating Instructions and Installation Xios XG USB Module and Sensors 4.4 Installing Intraoral Sensor Software for USB and WiFi devices 4. Click on "Install Intraoral Sensor Software" . 5. Follow the further instructions. 6. Restart the PC if you are required to do so.
  • Page 36: Connecting The Usb Module And Hub To The Pc

    "USB hub (optional)"  [→ 23]. IMPORTANT Only one Xios XG USB module may be connected to a PC. ü Sidexis 4 / SIDEXIS XG and the required plugin is installed on the 1. If an active USB hub is required, install it according to the manufacturer's instructions.
  • Page 37: Install Wall Holder For The Xios Xg Usb Module

    Dentsply Sirona 4 Installation Operating Instructions and Installation Xios XG USB Module and Sensors 4.6 Install wall holder for the Xios XG USB module Install wall holder for the Xios XG USB module A holder is supplied with the USB module. It can be screwed to a wall using the drywall screws provided or other mounting material.
  • Page 38: Install Wall Holder For The Xios Dentist Element Usb Module

    4 Installation Dentsply Sirona 4.7 Install wall holder for the Xios dentist element USB module Operating Instructions and Installation Xios XG USB Module and Sensors Install wall holder for the Xios dentist element USB module A holder is included in the scope of delivery of the USB module. It can be screwed to a wall using the drywall screws provided or other mounting material.
  • Page 39: Connect Sensor

    Operating Instructions and Installation Xios XG USB Module and Sensors 4.8 Connect sensor Connect sensor A calibration file is saved on the Xios XG Select and Xios XG Supreme sensors that is transferred to the PC the first time that the sensor is used.
  • Page 40: Operation

    5 Operation Dentsply Sirona 5.1 Establishing exposure readiness in SIDEXIS XG Operating Instructions and Installation Xios XG USB Module and Sensors Operation Establishing exposure readiness in SIDEXIS XG 1. Connect a sensor to the USB or WiFi module. 2. Register the patient in SIDEXIS XG. Detailed information can be found in the SIDEXIS XG operator's manual.
  • Page 41 5. Select the Xios XG USB/WiFi module. Ä The "Exposure readiness " window is displayed. SIDEXIS XG is ready for exposures when the green display is flashing there. "Exposure readiness " window when using a Xios XG Select sensor 64 09 713 D3610 D3610.201.01.14.02    2023-02...
  • Page 42: Establishing Exposure Readiness With Sidexis 4 Sensor Plugin

    Operating Instructions and Installation Xios XG USB Module and Sensors "Exposure readiness " window when using a Xios XG Supreme sensor 6. When using a Xios XG Supreme sensor: Select the desired filter to be applied to the x-ray image produced depending on the indication.
  • Page 43 Dentsply Sirona 5 Operation Operating Instructions and Installation Xios XG USB Module and Sensors 5.2 Establishing exposure readiness with Sidexis 4 sensor plugin Example of selecting an exposure series There are two types of templates: ● A template in which exposures of different anatomical regions are acquired, e.g., for "Bitewings"...
  • Page 44: Example Of Taking An Image (Series)

    5 Operation Dentsply Sirona 5.2 Establishing exposure readiness with Sidexis 4 sensor plugin Operating Instructions and Installation Xios XG USB Module and Sensors 5.2.1.1 Example of taking an image (series) ü The Sidexis 4 Sensor Plugin is now installed. ü The patient is registered.
  • Page 45 Dentsply Sirona 5 Operation Operating Instructions and Installation Xios XG USB Module and Sensors 5.2 Establishing exposure readiness with Sidexis 4 sensor plugin Exposure series "Bitewings" 4. Trigger the X-ray exposure. Ä Following the exposure, the X-ray image is displayed in the preview window.
  • Page 46 5 Operation Dentsply Sirona 5.2 Establishing exposure readiness with Sidexis 4 sensor plugin Operating Instructions and Installation Xios XG USB Module and Sensors Post-exposure options IMPORTANT Other actions are also available after each exposure. These include changing image orientation (A), using the exposure meter (B), performing an image retake (C), and changing the tooth numbering (D).
  • Page 47 Dentsply Sirona 5 Operation Operating Instructions and Installation Xios XG USB Module and Sensors 5.2 Establishing exposure readiness with Sidexis 4 sensor plugin Exposure series complete Exposure series (individual images and exam) in the "Timeline" Ä The individual exposures as well as the exposure series are displayed in the "Exposures"...
  • Page 48: Repeating An Exposure In The Series

    5 Operation Dentsply Sirona 5.2 Establishing exposure readiness with Sidexis 4 sensor plugin Operating Instructions and Installation Xios XG USB Module and Sensors 5.2.1.2 Repeating an exposure in the series Performing an image retake — a feature also available in the "Light Box"...
  • Page 49: Canceling An Exposure Series

    Dentsply Sirona 5 Operation Operating Instructions and Installation Xios XG USB Module and Sensors 5.2 Establishing exposure readiness with Sidexis 4 sensor plugin 5.2.1.3 Canceling an exposure series If some of the images of an exposure series are not needed, they can also be canceled prematurely.
  • Page 50 Dentsply Sirona 5.2 Establishing exposure readiness with Sidexis 4 sensor plugin Operating Instructions and Installation Xios XG USB Module and Sensors Ä Placeholders (B) are displayed in the "Light box" of the "Examination" work phase for the exposures of the series that are not used.
  • Page 51: Continuing An Exposure Series

    Dentsply Sirona 5 Operation Operating Instructions and Installation Xios XG USB Module and Sensors 5.2 Establishing exposure readiness with Sidexis 4 sensor plugin 5.2.1.4 Continuing an exposure series An exposure series that has been interrupted can be continued later at any time.
  • Page 52: Templates For The Exposure Series

    5 Operation Dentsply Sirona 5.2 Establishing exposure readiness with Sidexis 4 sensor plugin Operating Instructions and Installation Xios XG USB Module and Sensors Starting the series dialog / exposure series 4. Make the X-ray exposure to continue with the series.
  • Page 53: Establish Exposure Readiness With The Intraoral Sensor Software (Ioss)

    Dentsply Sirona 5 Operation Operating Instructions and Installation Xios XG USB Module and Sensors 5.3 Establish exposure readiness with the Intraoral Sensor Software (IOSS) Establish exposure readiness with the Intraoral Sensor Software (IOSS) 5.3.1 Enter indications Indications include information about the current exam, as listed below, which can be edited if needed.
  • Page 54: Select A Template

    Dentsply Sirona 5.3 Establish exposure readiness with the Intraoral Sensor Software (IOSS) Operating Instructions and Installation Xios XG USB Module and Sensors Connecting any compatible sensor makes it available immediately to acquire images. For convenience, the most recently used sensor is pre- selected.
  • Page 55: Determine Unit Status (Xios Xg Usb Module)

    Operating Instructions and Installation Xios XG USB Module and Sensors 5.4 Determine unit status (Xios XG USB module) Determine unit status (Xios XG USB module) The Xios XG USB module features three LED displays. They indicate the unit status. Sensor...
  • Page 56: Determine Unit Status

    5 Operation Dentsply Sirona 5.5 Determine unit status Operating Instructions and Installation Xios XG USB Module and Sensors Determine unit status The AE Sensor USB interface features two LEDs. They indicate the unit status. Connection Status LED Indications Interface Connection status LED...
  • Page 57: Select The Exposure Parameters For The X-Ray Tube Assembly

    5.6.2 Recommended dose for Xios XG sensors Xios XG sensors have a very wide effective dose area, so that, depending on the object and diagnostic question at hand, it is always possible to select optimal parameter settings. IMPORTANT...
  • Page 58: Heliodent Plus Exposure Times

    5 Operation Dentsply Sirona 5.6 Select the exposure parameters for the X-ray tube assembly Operating Instructions and Installation Xios XG USB Module and Sensors 5.6.3 HELIODENT Plus exposure times 5.6.3.1 Pre-programmed exposure times for XIOS XG sensors with 200 mm (8") FHA cone 0.01...
  • Page 59: Pre-Programmed Exposure Times For Xios Xg Sensors With 300

    Dentsply Sirona 5 Operation Operating Instructions and Installation Xios XG USB Module and Sensors 5.6 Select the exposure parameters for the X-ray tube assembly 5.6.3.2 Pre-programmed exposure times for XIOS XG sensors with 300 mm (12") FHA cone (round or square cone) 0.03...
  • Page 60: Sliding The Hygienic Protective Sleeve Over The Sensor

    Sliding the hygienic protective sleeve over the sensor Hygienic protective sleeves are available depending on the size of the sensor (0, 1 or 2). They fit both Xios XG Select and Xios XG Supreme sensors. To reorder the hygienic protective sleeves, see "Consumables and spare parts".
  • Page 61 ➢ Inspect the sensor cable visually for damage every day. NOTE The Xios XG USB components and Xios XG sensors must not be exposed to any mechanical influences, such as vibrations from impacts or falls.
  • Page 62: Position Sensor With Single-Use Sensor Holder System

    5 Operation Dentsply Sirona 5.8 Position the sensor Operating Instructions and Installation Xios XG USB Module and Sensors 5.8.1 Position sensor with single-use sensor holder system 5.8.1.1 Notes on the sensor holder tabs IMPORTANT The sensor holder tabs are single use devices and cannot be reused.
  • Page 63: Alignment Of The X-Ray Image

    Dentsply Sirona 5 Operation Operating Instructions and Installation Xios XG USB Module and Sensors 5.8 Position the sensor 5.8.1.2 Alignment of the X-ray image The sensor alignment is shown on the X-ray image by a small rectangle of inverted pixels.
  • Page 64: Anterior Tooth Exposure

    5 Operation Dentsply Sirona 5.8 Position the sensor Operating Instructions and Installation Xios XG USB Module and Sensors 5.8.1.3 Anterior tooth exposure For anterior tooth exposures use the blue sensor holder. 1. Place the blue localizer ring (B) onto the triple-angled guide rod (C).
  • Page 65: Posterior Tooth Exposures

    Dentsply Sirona 5 Operation Operating Instructions and Installation Xios XG USB Module and Sensors 5.8 Position the sensor 5.8.1.4 Posterior tooth exposures For posterior tooth exposures use the yellow sensor holder. 1. Place the yellow localizer ring (B) onto the double-angled guide rod (C).
  • Page 66: Bite Wing Exposures

    5 Operation Dentsply Sirona 5.8 Position the sensor Operating Instructions and Installation Xios XG USB Module and Sensors 5.8.1.5 Bite wing exposures For bite wing exposures use the red sensor holder. 1. Place the red localizer ring (B) onto the straight guide rod (C).
  • Page 67: Endodontics Exposures With The Half-Angle Technique

    Dentsply Sirona 5 Operation Operating Instructions and Installation Xios XG USB Module and Sensors 5.8 Position the sensor 5.8.1.6 Endodontics exposures with the half-angle technique For endodontics exposures with the half-angle technique use the green universal sensor holder tab. 1. Slide the sensor into the hygienic protective sleeve, see section "Slide the hygienic protective sleeve over the sensor".
  • Page 68: Measurement Exposure For Endodontics

    5 Operation Dentsply Sirona 5.8 Position the sensor Operating Instructions and Installation Xios XG USB Module and Sensors 5.8.1.7 Measurement exposure for endodontics Endodontic needles and files can remain in the root canal for the measurement exposure. For endodontics exposures use the grey sensor holder.
  • Page 69: Positioning The Sensor With The Aimright Reusable Sensor Holder System

    Dentsply Sirona 5 Operation Operating Instructions and Installation Xios XG USB Module and Sensors 5.8 Position the sensor 5.8.2 Positioning the sensor with the AimRight reusable sensor holder system 5.8.2.1 Anterior tooth exposure Preparing the sensor holder For anterior tooth exposures use the blue sensor holder.
  • Page 70 5 Operation Dentsply Sirona 5.8 Position the sensor Operating Instructions and Installation Xios XG USB Module and Sensors Positioning the sensor for exposures of the lower jaw 1. Look through the localizer ring to check the alignment of the sensor.
  • Page 71 Dentsply Sirona 5 Operation Operating Instructions and Installation Xios XG USB Module and Sensors 5.8 Position the sensor Positioning the sensor for exposures of the upper jaw 1. Look through the localizer ring to check the alignment of the sensor.
  • Page 72 5 Operation Dentsply Sirona 5.8 Position the sensor Operating Instructions and Installation Xios XG USB Module and Sensors 5. Align the cone of the X-ray tube assembly parallel to the sensor directly on the localizer ring. 6. Release an X-ray exposure. Refer to sections Select the exposure parameters for the X-ray tube assembly ...
  • Page 73: Posterior Tooth Exposures

    Dentsply Sirona 5 Operation Operating Instructions and Installation Xios XG USB Module and Sensors 5.8 Position the sensor 5.8.2.2 Posterior tooth exposures Preparing the sensor holder For posterior tooth exposures use the yellow sensor holders. 1. For the right upper jaw and left lower jaw: Fasten the guide rod for the sensor holder (C) in the perforation (B) of the localizer ring (A).
  • Page 74 5 Operation Dentsply Sirona 5.8 Position the sensor Operating Instructions and Installation Xios XG USB Module and Sensors Position the sensor 1. Look through the localizer ring to check the alignment of the sensor. The sensor must be located centrally in front of the opening in the localizer ring.
  • Page 75 Dentsply Sirona 5 Operation Operating Instructions and Installation Xios XG USB Module and Sensors 5.8 Position the sensor Ä Example: Positioning on the upper jaw 3. Align the cone of the X-ray tube assembly parallel to the sensor directly on the localizer ring.
  • Page 76: Horizontal Bite Wing Exposures

    5 Operation Dentsply Sirona 5.8 Position the sensor Operating Instructions and Installation Xios XG USB Module and Sensors 5.8.2.3 Horizontal bite wing exposures Preparing the sensor holder For bite wing exposures use the red sensor holder. 1. Fasten the guide rod for the sensor (C) in the perforation (B) of the localizer ring (A).
  • Page 77 Dentsply Sirona 5 Operation Operating Instructions and Installation Xios XG USB Module and Sensors 5.8 Position the sensor 2. Position the sensor directly on the dental arch. Ä The bite block of the sensor holder must be located between the upper molars, parallel to the occlusal plane.
  • Page 78: Releasing The Exposure

    5 Operation Dentsply Sirona 5.9 Releasing the exposure Operating Instructions and Installation Xios XG USB Module and Sensors Releasing the exposure ü The exposure parameters for the X-ray tube assembly are set. See "Setting exposure parameters for the X-ray tube assembly"  [→ 57].
  • Page 79: Example Of Taking An Image (Series) With Intraoral Sensor Software

    Dentsply Sirona 5 Operation Operating Instructions and Installation Xios XG USB Module and Sensors 5.10 Example of taking an image (series) with Intraoral Sensor Software 5.10 Example of taking an image (series) with Intraoral Sensor Software Menu selections for image acquisition ü...
  • Page 80: Repeating An Exposure In The Series

    5 Operation Dentsply Sirona 5.10 Example of taking an image (series) with Intraoral Sensor Software Operating Instructions and Installation Xios XG USB Module and Sensors 5.10.1 Repeating an exposure in the series Performing an image retake — a feature also available in the "Light Box"...
  • Page 81: Removing The Hygienic Protective Sleeve From The Sensor

    Dentsply Sirona 5 Operation Operating Instructions and Installation Xios XG USB Module and Sensors 5.11 Removing the hygienic protective sleeve from the sensor 5.11 Removing the hygienic protective sleeve from the sensor 5.11.1 With single-use sensor holder system Have the sensor holder tab and the sensor holder glued onto the hygienic protective sleeve.
  • Page 82 5 Operation Dentsply Sirona 5.11 Removing the hygienic protective sleeve from the sensor Operating Instructions and Installation Xios XG USB Module and Sensors 3. Slide the sensor further out of the hygienic protective sleeve with your thumb. 4. Hold the sensor cable firmly to prevent the sensor from falling out of the hygienic protective sleeve.
  • Page 83: With Aimright Reusable Sensor Holder System

    Dentsply Sirona 5 Operation Operating Instructions and Installation Xios XG USB Module and Sensors 5.11 Removing the hygienic protective sleeve from the sensor 5.11.2 With Aimright reusable sensor holder system NOTE The sensor cable is sensitive to mechanical influences. The cable may become damaged or may wear out prematurely.
  • Page 84: Edit And Enhance Exposures

    6 Edit and enhance exposures Dentsply Sirona 6.1 Working with images in Acquisition view Operating Instructions and Installation Xios XG USB Module and Sensors Edit and enhance exposures Item number Description Re-orient image (rotate left or right) Exposure meter Retake image...
  • Page 85: Changing Image Orientation

    Dentsply Sirona 6 Edit and enhance exposures Operating Instructions and Installation Xios XG USB Module and Sensors 6.1 Working with images in Acquisition view ü There is at least one image in the series and one or more additional exposure windows.
  • Page 86: Reading The Exposure Meter

    Dentsply Sirona 6.1 Working with images in Acquisition view Operating Instructions and Installation Xios XG USB Module and Sensors ü There is at least one image in the series. 1. Locate the edit button (after Tooth # ) and click on it.
  • Page 87: Enhancing Exposures (Xios Ae And Schick Ae)

    Dentsply Sirona 6 Edit and enhance exposures Operating Instructions and Installation Xios XG USB Module and Sensors 6.2 Enhancing exposures (Xios AE and Schick AE) Ä The "Retake" image window is displayed, consisting of two exposure windows— "Current Image" and "New Image" .
  • Page 88: Enhancing Exposures (Xios Xg Supreme And Schick 33)

    To apply an enhancement or to select a task, perform the following steps: 1. Open a Xios XG Supreme or Schick 33 image in the "Light Box" . 2. Click on the "Tools" docking window. 3. In the "Filter" tool kit, click on "Intraoral Enhancements" to expand it, then select a "Task"...
  • Page 89: Recovery Mode

    Dentsply Sirona 7 Recovery mode Operating Instructions and Installation Xios XG USB Module and Sensors 7.1 Resend images in Recovery mode (recommended) Recovery mode During normal use, Sidexis software saves patient data and images to the server and makes them available whenever needed. In some situations, however, communication with the Sidexis server may be disrupted, preventing images from being saved properly.
  • Page 90: Resend Images In Recovery Mode (Sidexis)

    7 Recovery mode Dentsply Sirona 7.2 Resend images in Recovery mode (Sidexis) Operating Instructions and Installation Xios XG USB Module and Sensors Resend images in Recovery mode (Sidexis) To recover unsaved images, please perform the following steps: ü Resolve the issue that caused "Sidexis 4" to enter "Recovery mode"...
  • Page 91 Dentsply Sirona 7 Recovery mode Operating Instructions and Installation Xios XG USB Module and Sensors 7.3 Export images in Recovery mode (alternate) 10. In the "Intraoral Sensor Configuration App" , if you have not attempted successfully to recover images by resending them, which is the recommended approach, this is an opportunity to do so.
  • Page 92: Configuration

    8 Configuration Dentsply Sirona 8.1 Intraoral Sensor Configuration App Operating Instructions and Installation Xios XG USB Module and Sensors Configuration Intraoral Sensor Configuration App The "Intraoral Sensor Configuration App" is an application that provides several features to ensure that intraoral devices, such as sensors and...
  • Page 93: Sensors

    Dentsply Sirona 8 Configuration Operating Instructions and Installation Xios XG USB Module and Sensors 8.1 Intraoral Sensor Configuration App Intraoral Sensor Software Configuration App Home 8.1.2 Sensors The Sensors page displays information about intraoral sensors, connected either by USB or by WiFi interface, to the PC workstation.
  • Page 94 8 Configuration Dentsply Sirona 8.1 Intraoral Sensor Configuration App Operating Instructions and Installation Xios XG USB Module and Sensors Interface. Additional troubleshooting can be performed if another USB Interface is available. In this case, connecting a different USB device to the USB cable and repeating the USB Interface Test may help to identify the possible cause of the problem.
  • Page 95 Dentsply Sirona 8 Configuration Operating Instructions and Installation Xios XG USB Module and Sensors 8.1 Intraoral Sensor Configuration App Sensor information for Schick 33 Sensor information for Xios AE 64 09 713 D3610 D3610.201.01.14.02    2023-02...
  • Page 96: Recovery

    8 Configuration Dentsply Sirona 8.1 Intraoral Sensor Configuration App Operating Instructions and Installation Xios XG USB Module and Sensors Sensor information for Schick 33 Wireless 8.1.3 Recovery The Recovery page provides a quick status of the "Intraoral Sensor Software" and the capability of the intraoral system to acquire images. It can also be used to close imaging sessions, if they were interrupted unexpectedly, and release the sensor for new exposures.
  • Page 97 Dentsply Sirona 8 Configuration Operating Instructions and Installation Xios XG USB Module and Sensors 8.1 Intraoral Sensor Configuration App Intraoral Sensor Software Configuration App Recovery Before Image Recovery 64 09 713 D3610 D3610.201.01.14.02    2023-02...
  • Page 98: About

    8 Configuration Dentsply Sirona 8.1 Intraoral Sensor Configuration App Operating Instructions and Installation Xios XG USB Module and Sensors After Image Recovery Closing Acquisition Session and Releasing Sensor for New Exposures 8.1.4 About The About page displays sensor and software version information.
  • Page 99 Dentsply Sirona 8 Configuration Operating Instructions and Installation Xios XG USB Module and Sensors 8.1 Intraoral Sensor Configuration App used also to check for updates to the "Intraoral Sensor Software" . An internet connection is required to perform this check.
  • Page 100: Maintenance And Inspection

    9 Maintenance and inspection Dentsply Sirona 9.1 Hygiene Operating Instructions and Installation Xios XG USB Module and Sensors Maintenance and inspection Hygiene Disinfect and sterilize accessories prior to initial use and after each patient. 9.1.1 Care, cleaning agents, and disinfectants...
  • Page 101 Dentsply Sirona 9 Maintenance and inspection Operating Instructions and Installation Xios XG USB Module and Sensors 9.1 Hygiene 2. The sensor and the sensor cable must be wiped clean with disinfectant completely and thoroughly at least twice. After this, wipe USB module or the WiFi interface and the charger clean with disinfectant.
  • Page 102: Sensor Holders

    Operating Instructions and Installation Xios XG USB Module and Sensors 9.1.3 Sensor holders The rods and rings of the Xios XG single-use sensor holder system and all parts of the AimRight reusable sensor holder system can be sterilized. The rods and rings or sensor holder and rings must be sterilized before initial use and once a treatment has ended.
  • Page 103: Regular Inspections

    Dentsply Sirona 9 Maintenance and inspection Operating Instructions and Installation Xios XG USB Module and Sensors 9.2 Regular inspections Regular inspections Inspections must be performed at scheduled intervals to protect the health and safety of patients, users and other persons.
  • Page 104: Replace The Sensor Cable

    9 Maintenance and inspection Dentsply Sirona 9.3 Replace the sensor cable Operating Instructions and Installation Xios XG USB Module and Sensors Replace the sensor cable The sensor cable can be replaced with a new one in the event of damage.
  • Page 105 Dentsply Sirona 9 Maintenance and inspection Operating Instructions and Installation Xios XG USB Module and Sensors 9.3 Replace the sensor cable 3. Using the screwdriver supplied with the set, remove the two screws that fasten the cable to the sensor.
  • Page 106 Initially tighten the screws only until a light resistance can be felt. After this tighten both screws carefully. 3. For Xios XG Select and Xios XG Supreme sensors: Place a silicone protective cap over every screw. For Xios AE sensors: For each screw that you just tightened, take a gel disk from the protective paper and place it on the screw.
  • Page 107: Cable Clips For The Xios Dentist Element Usb Cable

    Dentsply Sirona 9 Maintenance and inspection Operating Instructions and Installation Xios XG USB Module and Sensors 9.4 Cable clips for the Xios dentist element USB cable Cable clips for the Xios dentist element USB cable 9.4.1 Desktop surfaces 1. To attach a cable clip for an interface located on a desktop surface, we recommend disconnecting the USB cable from the USB interface.
  • Page 108 Dentsply Sirona 9.4 Cable clips for the Xios dentist element USB cable Operating Instructions and Installation Xios XG USB Module and Sensors 4. Connect the USB cable to the interface so it is positioned inside the loop of the cable clip.
  • Page 109: Wall Holders

    Dentsply Sirona 9 Maintenance and inspection Operating Instructions and Installation Xios XG USB Module and Sensors 9.4 Cable clips for the Xios dentist element USB cable 9.4.2 Wall holders 1. To attach a cable clip for an interface attached to a wall holder, we recommend disconnecting the USB cable from the USB iInterface.
  • Page 110 Dentsply Sirona 9.4 Cable clips for the Xios dentist element USB cable Operating Instructions and Installation Xios XG USB Module and Sensors 4. Connect the USB cable to the interface so it is positioned inside the loop of the cable clip.
  • Page 111: Consumables And Spare Parts

    Dentsply Sirona 10 Consumables and spare parts Operating Instructions and Installation Xios XG USB Module and Sensors Consumables and spare parts Hygienic protective sleeves for sensors Hygienic protective sleeves for sensor size 0 and 1, quantity 300 REF 64 09 960...
  • Page 112 10 Consumables and spare parts Dentsply Sirona Operating Instructions and Installation Xios XG USB Module and Sensors Aimright reusable sensor holder system Localizer ring (red), quantity 1 REF 65 45 599 Sensor holder for bite wing exposures (red), for sensor size 1, quantity...
  • Page 113 Dentsply Sirona 10 Consumables and spare parts Operating Instructions and Installation Xios XG USB Module and Sensors Sensor holder for posterior tooth exposures (yellow), for sensor size 1, quantity 4 (2 for right lower jaw / left upper jaw and 2 for left lower jaw / right upper...
  • Page 114 10 Consumables and spare parts Dentsply Sirona Operating Instructions and Installation Xios XG USB Module and Sensors Xios XG Supreme USB size 1, 270 cm REF 64 83 510 Xios XG Supreme USB size 2, 270 cm REF 64 83 528 Sensor cable for USB module...
  • Page 115: Electromagnetic Compatibility

    11.1 Accessories Electromagnetic compatibility Xios XG complies with the requirements for electromagnetic compatibility (EMC) according to IEC 60601-1-2. Xios XG is hereinafter referred to as "UNIT". Observance of the following information is necessary to ensure safe operation regarding EMC aspects. 11.1...
  • Page 116: Electromagnetic Emission

    11 Electromagnetic compatibility Dentsply Sirona 11.2 Electromagnetic emission Operating Instructions and Installation Xios XG USB Module and Sensors 11.2 Electromagnetic emission The UNIT is intended for operation in the electromagnetic environment specified below. The customer or user of the UNIT should make sure that it is used in such an environment.
  • Page 117: Interference Immunity

    Dentsply Sirona 11 Electromagnetic compatibility Operating Instructions and Installation Xios XG USB Module and Sensors 11.3 Interference immunity 11.3 Interference immunity The UNIT is intended for operation in the electromagnetic environment specified below. The customer or user of the UNIT should make sure that it is used in such an environment.
  • Page 118: Working Clearances

    11 Electromagnetic compatibility Dentsply Sirona 11.4 Working clearances Operating Instructions and Installation Xios XG USB Module and Sensors Interference immunity IEC 60601 1-2 test Compliance level Electromagnetic environment - tests level guidelines Conducted RF interfer- d= [1.2] √P ence 150 kHz to 80 MHz...
  • Page 119 Dentsply Sirona 11 Electromagnetic compatibility Operating Instructions and Installation Xios XG USB Module and Sensors 11.4 Working clearances Power rating of the transmitter Working clearance according to transmission frequency [m] 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2.5 GHz...
  • Page 120: Disposal

    12 Disposal Dentsply Sirona Operating Instructions and Installation Xios XG USB Module and Sensors Disposal In accordance with Directive 2012/19/EU and national disposal regulations regarding old electrical and electronic devices, please be advised that such items must be disposed of in a special way within the European Union (EU).
  • Page 121 Dentsply Sirona 12 Disposal Operating Instructions and Installation Xios XG USB Module and Sensors IMPORTANT Operators of equipment with storage functions for customer and patient data are responsible for deleting all personal data before disposing of the equipment. 64 09 713 D3610...
  • Page 122 We reserve the right to make any alterations which may be required due to technical improvements. © SIRONA Dental Systems GmbH Sprache: englisch Printed in Germany D3610.201.01.14.02      2023-02 Ä.-Nr.:  133 292 SIRONA Dental Systems GmbH 64 09 713 D3610 Fabrikstraße 31 Order No   ...

This manual is also suitable for:

Xios xg selectXios xg supreme

Table of Contents