3
WIRING
3.1
Encoder specification / terminating resistor switch setting
Encoder specification selection switch (SW3)
Selects either differential line driver or complementary.
It is initially set to the complementary. Switch its position according to the
output circuit.
Terminating resistor selection switch (SW1)
Selects "ON"/"OFF" of the internal terminating resistor.
Set the switch to "OFF (initial status)" when an encoder output type is
complementary and set to "ON" when differential line driver.
ON: with internal terminating resistor
OFF: without internal terminating resistor (initial status)
NOTE
• Set all switches to the same setting ("ON"/"OFF").
• Set the switch "OFF" when sharing an encoder with
another unit (NC (computerized numerical controller),
etc.) having a terminating resistor under the differential
line driver setting.
Complementary
(initial status)
Differential line
driver
3
Internal terminating
resistor-OFF
(initial status)
Internal terminating
resistor-ON
25