8.3 TECHNICAL DATA

Refrigerant
Weight
Model
(lb)
(Kg)
(oz)
ATT+ 060
838
380
60
ATT+ 090
926
420
60
Calibration
Min.
Hot gas valve
values
Air -side
Working
5-HGV
Pressure
ATT+ 060
29 PSIg
35÷38 PSIg
2 barg
2.4÷2.6 barg
ATT+ 090
IMPORTANT:
The flow rate of the Dew point is set ( 2.5 NL/m) for a work pressure of 5÷12 bar; if the work pressure is lower of the range, regulate the flow of the dew point on (2.5 NL/min)
using the valve (43).
MIN.- MAX
Ambient Temperature
R513a
Desiccant
Charge
(Silicant
During tran-
Gel)
spor
Air
and stokage
(Kg)
CO
e(t)
(lb)
(Kg)
2
1.7
0.97
35
16
32-122° F
0-50°C
1.7
0.97
49
22
Fan pressure
Working
condensation
Pressure
15
ON: 159 PSIg
ON: 11 bar
101 PSIg
7 bar
OFF: 116 PSIg
OFF: 8 bar
Air - Side
Compressed
Amb
Max
air inlet
Working
Temperature
After
Pressure
installa-
tion
In
42-122°F
41-149°F
174 PSIg
5-50°C
5-65°C
12 bar
Max.
High
High
Operating
temperature
pressure switch
Pressure
Set
13-HP
174 PSIg
248°F
290 PSIg
12 bar
120°C
20 barg
ATT+ 060-090
Minimum
Energy
section
Compres-
supply
F.L.A.
validated
(A)
cable for
electrical
connection
Air
Type
Ø
ISO VG32
2
19.4
230V/1ph/50Hz
3G4mm
ESTER 1.1/2"
Sound
LOW SIDE
HIGH SIDE
pressure level
Max .
Max .
Refrigerant
Refrigerant
Pressure
Pressure
14 - 29 PSIg
290 PSIg
[dB (A)]
barg
20 barg
<75
1.0-2.0
Compressed
air inlet
air outlet
sor Oil
Lub.
Type
BSPP-F
1.1/2"
Electrical
Protection
Class
IP44