Table of Contents

Advertisement

Available languages

Available languages

Quick Links

ATT
(Plus-E)
Antares Plus Tandem Dryer
(50Hz)
CABLE INLET
ATT+ 060
ATT+ 090
IT
Manuale d'uso
EN User Manual
DATE: 14.01.2023 - Rev. 00
CODE: 398H272219

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Antares Plus Tandem and is the answer not in the manual?

Questions and answers

Summary of Contents for Parker Antares Plus Tandem

  • Page 1 (Plus-E) Antares Plus Tandem Dryer (50Hz) CABLE INLET ATT+ 060 ATT+ 090 Manuale d’uso EN User Manual DATE: 14.01.2023 - Rev. 00 CODE: 398H272219...
  • Page 3 Sicurezza Indice ATTENZIONE: Il costruttore si riserva il diritto di modifi care le informazioni contenute nel presente manuale senza alcun preavvi- Sicurezza 1.1 Importanza del manuale so. Ai fi ni di una completa ed aggiornata informazione , si racco- 1.1 Importanza del manuale ..............1 manda all’utente di consultare il manuale a bordo dell’unità.
  • Page 4: Installazione

    ATT+ 060-090 2 / 14 Italiano Introduzione Versione ad acqua (Wc) Controllare il corretto defl usso degli scarichi condensa. Smaltire tutta la Se non previsto in fornitura, installare fi ltro a rete su ingresso acqua di condensa in conformità alle locali normative ambientali vigenti. Questo manuale si riferisce a essiccatori progettati per garantire alta condensazione.
  • Page 5: Messa In Servizio

    Messa in servizio 4.3 Funzionamento Controllo a) Lasciare in marcia l’essiccatore durante tutto il periodo di funziona- 5.1 Pannello di controllo (Home) 4.1 Controlli preliminari mento del compressore d’aria; b) L’essiccatore funziona in modo automatico, non sono quindi richie- Prima di avviare l’essiccatore verifi care che: ste tarature sul campo;...
  • Page 6: Menu Timer

    ATT+ 060-090 4 / 14 Italiano 5.2 Menu timer Tasti Touch Funzione Essiccatore Toccare per entrare nel menu “Timer”: ON/OFF Spento (grigio) Toccare per qual- che secondo per acceso (verde) partire/spegnere Locale remoto Toccare per accedere al menu informazioni: stato macchina, pressioni, temperature, impostazioni generali, consumi, password utente Toccare per verifi care l’allarme.
  • Page 7 5.4 Menu informazione 5.4.1 Stop immediato 5.4.3 Grafi ci Toccare per entrare nel menu “immediate stop”. Toccare per entrare nel menu“Trend selection”. Toccare per entrare nel menu “system information”. Grafi co 1 delle temperature Toccare per confermare e spegnere il dryer. impostazioni generali usare per scorrere sul grafi co.
  • Page 8 ATT+ 060-090 6 / 14 Italiano 5.4.4 Stato ingressi/uscite analogici/digitali Uscite digitali toccare per vedere il Grafi co delle pressioni Toccare per entrare nel menu“Status I/O”. Ingressi Analogici Attivo = bianco Non Attivo = nero usare per scorrere sul grafi co. toccare per vedere il successivo sare...
  • Page 9: Storico Allarmi

    5.4.5 Storico allarmi Tabella Allarmi/Avvisi Codice Descrizione Reset Stop Stop Note Toccare per entrare nel menu“Alarm Buffer”. dryer Adsorber aB8HH Allarme alta Temp. mandata (B8) aB0L Allarme bassa Temp. Dew Point (B0) aB2L Allarme bassa Temp. Evaporazione (B2) aP1EP Allarme pressione di mandata (P1) aCS1 Allarme scaricatore di condensa (CS1) si blocca dopo 3 tentativi...
  • Page 10: Impostazione Generale

    ATT+ 060-090 8 / 14 Italiano 5.4.7 Funzionamento cicli e tempi 5.4.9 Impostazione generale Toccare per entrare nel menu“Operation huors & Toccare per entrare nel menu“General setting”. cycles”. toccare per vedere il Grafi co successivo Toccare per tornare al menu precedente. Toccare per tornare al pannello di controllo.
  • Page 11 5.4.9.1 Lingua/unità di misura 5.4.9.4 Impostazione adsorbitore Toccare Toccare per entrare nel menu“Language setting”. Toccare per entrare nel menu“Adsober setting” HMI only = ON/OFF solo da touch HMI and WIRED = ON/OFF da touch e da remoto. Toccare per tornare al menu precedente. Toccare per tornare al pannello di controllo.
  • Page 12: Menu Rapido

    ATT+ 060-090 10 / 14 Italiano 5.4.9.6 Impostazione Data 5.4.9.8 Impostazione ausiliari 5.5 Menu rapido Raggiungere il menu in brevi passaggi: Toccare per entrare nel menu“Dryer setting”. Toccare per entrare nel menu“Auxiliaries settings”. Menu “tempi” Toccare Allarmi Toccare Stop immediato Toccare Toccare Matricola...
  • Page 13: Manutenzione

    Cambia lingua/unità di misura Impostazione allarmi Manutenzione a) La macchina è progettata e costruita per garantire un funzionamen- Toccare Toccare to continuativo; la durata dei suoi componenti è però direttamente Toccare legata alla manutenzione eseguita. Toccare In caso di richiesta di assistenza o ricambi, identifi care la mac- Toccare Toccare china (modello e numero di serie) leggendo la targhetta di identifi ca-...
  • Page 14: Programma Di Manutenzione Preventiva

    ATT+ 060-090 12 / 14 Italiano maschera antipolvere ed occhiali di protezione; cializzato e autorizzato. 6.5 Smantellamento b) se sparso a terra, raccogliere subito l’agente essiccante; Tutte le parti di ricambio e i loro rispettivi codici si possono trovare Il fl uido frigorigeno e l’olio lubrifi cante contenuto nel circuito dovranno elencati nel paragrafo 9.4.
  • Page 15: Ricerca Guasti

    Ricerca guasti RIMEDIO GUASTO CAUSA Termostato sicu- Picco di rumorosità in Alta pressione su rezza a riarmo manuale Avviso di cambio fi ltro Avviso sensore fase di purga colonna 1,2 attivo Passato 1 anno da Aria non suffi ciente per la Aumentare qtà...
  • Page 16 ATT+ 060-090 14 / 14 Italiano RIMEDIO GUASTO CAUSA Alta Temperatura Bassa pressione Allarme By-pass guasto/aperto Alta pressione pressostato sensore Pressostato Mancanza refrigeran- Alta temperatura aria di Ridurre Temp.aria di te ricaricare Basso assorbimento Pressostato LP guasto Sostituire raffreddamento raffreddamento Ridurre qtà/temp aria Carico termico eccessivo in ingresso...
  • Page 17 Safety indice IMPORTANT: The manufacturer reserves the right to modify this manual at any time. The most comprehensive and updated Safety 1.1 Importance of the manual information, the user is advised to consult the manual supplied 1.1 Importance of the manual ..............1 with the unit.
  • Page 18: Installation

    ATT+ 060-090 2 / 14 English Introduction If not provided in the supply, fi t a mesh fi lter on the condensation water Make the connection to the draining system, avoiding connection in inlet. a closed circuit shared by other pressurized discharge lines. Check the This manual refers to refrigeration dryers designed to guarantee high correct fl ow of condensate discharges.
  • Page 19: Operation

    Commissioning 4.3 Operation Control a) Leave the dryer on during the entire period the air compressor is 4.1 Preliminary checks working; 5.1 Home screen (Home) b) The dryer operates in automatic mode, therefore fi eld settings are Before starting the dryer, make sure: not required;...
  • Page 20 ATT+ 060-090 4 / 14 English 5.2 Menu timer Touch buttons Function Dryer ON/OFF Touch to enter on “Timer” menu: OFF (gray) Touch for few seconds for ON/OFF ON (green) Access to information menu: machine status, pressures, temperatures, general settings, con- sumption, user password Gray = no alarm Red = warning...
  • Page 21 5.4 System information menu 5.4.1 Immediate stop 5.4.3 Trend Touch to enter on “immediate stop” menu. Touch to enter on “Trend selection” menu. Touch to enter on “system information” menu. Temperatures trend Touch to confi rm and switch off the dryer. General setting to scroll on the graph.
  • Page 22 ATT+ 060-090 6 / 14 English 5.4.4 Status input/output analog/digital Digital output Touch to shows the pressure trend. Touch to enter on “Status I/O” menu. Analog input Active = blanc Not Active = black to scroll on the graph. Touch to enter on the next page.
  • Page 23: Event Buffer

    5.4.5 Alarms Buffer Alarm/Warning tabel Code Description Reset Stop Stop Note Touch to enter on “Alarm Buffer” menu. dryer Adsorber aB8HH High Temp. discharge alarm (B8) aB0L Low Temp. Dew Point alarm (B0) aB2L Low Temp. Evaporating alarm (B2) aP1EP Discharge pressure alarm (P1) aCS1 Condensate drain alarm (CS1)
  • Page 24: General Setting

    ATT+ 060-090 8 / 14 English 5.4.7 Operation Hours & cycles 5.4.9 General setting Touch to enter on “Operation huors & cycles” Touch to enter on “General setting” menu. menu. Touch to enter on the next page. Touch to return to the previous menu. Alarms setting Touch to enter on the next page.
  • Page 25 5.4.9.1 Language HMI only = ON/OFF only from touch 5.4.9.4 Adsorber setting HMI and WIRED = ON/OFF from touch and remote. Touch to enter on “Language setting” menu. Touch to enter on“Adsober setting” menu Touch to return to the previous menu. Touch to return to control panel.
  • Page 26: Alarm Settings

    ATT+ 060-090 10 / 14 English 5.4.9.6 Data time settings 5.4.9.8 Auxiliaries settings 5.5 Rapid menu Reach the manu in short steps: Touch to enter on “data time setting”. Touch to enter on “Auxiliaries settings” menu. Menu “Time” Touch Alarm Touch Immediate stop Touch...
  • Page 27: Maintenance

    Linguage/unit measure Alarm settings Maintenance a) The machine is designed and built to guarantee continuous opera- Touch Touch tion; however, the life of its components depends on the maintenan- Touch ce performed. Touch b) When requesting assistance or spare parts, identify the machine Touch (model and serial number) by reading the data plate located on the Touch...
  • Page 28: Recycling Disposal

    ATT+ 060-090 12 / 14 English 6.4 Preventive Maintenance Programme 6.5 Dismantling Contact supplier To guarantee lasting maximum dryer effi ciency and reliability: The refrigerant and the lubricant oil contained in the circuit must be re- For any maintenance please note the following warnings: covered in conformity with the current local environmental regulations.
  • Page 29: Troubleshooting

    Troubleshooting REMEDY FAULT CAUSE Heater Manual Warning Adsorber High pressure Column reset Noise in purge phases Warning Probe check fi lters Safety Thermostat Air is not suffi cient for Past 1 year from the Substitute the Increasing inlet air Drain solenoid defective regeneration replacement element fi lters...
  • Page 30 ATT+ 060-090 14 / 14 English REMEDY FAULT CAUSE High Temperature byt Low Pressure by Pressure High pressure by By-pass Alarm fail/open Pressure Switch Switch Pressure Switch Lower No refrigerant recharge Cooling air high Decrease cooling air Pressure switch defect current consumption substitute temperature...
  • Page 31 Appendice Anhang Apéndice Appendix CABLE INLET Appendice Bilaga Liittet Tillæg Anexo Bijlage Appendiks Aneks Příloha Tartalom Παράρτημα Приложение...
  • Page 33 CONTEST 8.1 LEGEND ..............................2 8.2 INSTALLATION DIAGRAM ........................9 8.3 TECHNICAL DATA ..........................11 SUPERVISOR PARAMETERS ....................... 13 8.4 SPARE PARTS ............................15 8.5 EXPLODED DRAWING ATT140 ......................18 ..EXPLODED DRAWING ATT260-340 ...................... 24 8.6 REFRIGERANT CIRCUIT ATT140 ......................25 ..REFRIGERANT CIRCUIT ATT260-340 Ac ....................
  • Page 34 8.1 LEGEND ATT+ 060-090 Symbol IT/DE/ES/EN FR/SV/FI/DA PT/NL/NO/PL CS/HU/EL/RU Peso Poids Peso Váha Gewicht Vikt Gewicht Súly Peso Paino Vekt Bάρος Weight Vægt Ciężar Hmotnost ’ Temperatura ambiente Température ambiante Temperatura ambiente Teplota prostředí Umgebungstemperatur Omgivningstemperatur Omgevingstemperatuur Környezeti hőmérséklet Temperatura ambiente Ympäristön lämpötila Omgivelsestemperatur Θερμοκραοία...
  • Page 35 Symbol IT/DE/ES/EN FR/SV/FI/DA PT/NL/NO/PL CS/HU/EL/RU Uscita aria compressa Sortie air comprimé Saída de ar comprimido Výstup stlačeného vzduchu Druckluftaustritt Tryckluftsutlopp Uitgang perslucht Sűrített levegő kimenet Salida del aire comprimido Paineilman poisto Trykkluftutgang Έξοδος πεπιεσμένου αέρα Compressed air outlet Udgang trykluft Wylot sprężonego powietrza Выход...
  • Page 36 8.1 LEGEND ATT+ 060-090 Symbol IT/DE/ES/EN FR/SV/FI/DA PT/NL/NO/PL CS/HU/EL/RU Condensatore refrigerante Condenseur réfrigérant Condensador refrigerante Kondenzátor chladivo Kältemittelkondensator Kylkondensator Condensor koelvloeistof Hűtő kondenzátor Condensador refrigerante Jäähdytyskondensaattori Kjølerkondensator Ψυκτικός συμπιεστής Refrigerant condenser Kølekondensator Kondensator czynnika chłodniczego Κοнденсатор хладагентаKondenzátor chladiva Elettroventilatore Électroventilateur Ventilador eléctrico Elektrický...
  • Page 37 Symbol IT/DE/ES/EN FR/SV/FI/DA PT/NL/NO/PL CS/HU/EL/RU Sonda temperatura IR11 Sonde température IR11 Sonda da temperatura IR11 Sonda teploty IR11 Temperatursensor IR11 Temperatursond IR11 Temperatuursonde IR11 Hõmérsékleti szonda IR11 Sonda de temperatura IR11 Lämpötila-anturi IR11 Trykksmålere IR11 Αισθητήρας Θερμ. IR11 Temperature sensor IR11 Temperaturføler IR11 Sonda temperatury IR11 Датчик...
  • Page 38 8.1 LEGEND ATT+ 060-090 Symbol IT/DE/ES/EN FR/SV/FI/DA PT/NL/NO/PL CS/HU/EL/RU Sonda temperatura evaporatore Sonde température évaporateur Sonda da temperatura do evaporador Sonda teploty výměníku Temperatursensor Verdampfer Evaporatortemperatursond Temperatuursonde verdamper Párologtató hőmérsékleti szonda Sonda de temperatura del evaporador Haihduttimen lämpötila-anturi Temperatursensor fordamper Αισθητήρας...
  • Page 39 Symbol IT/DE/ES/EN FR/SV/FI/DA PT/NL/NO/PL CS/HU/EL/RU Manometro Vessel Manomètre Réservoir Manómetro Reservatório Tlakoměr Zásobník Manometer Behälter Tankmanometer Manometer Reservoir Tartály nyomásmérő Manómetro Recipiente Säiliö painemittari Tank manometer Μανόμετρο Δεξαμενή Vessel Manometer Beholder manometer Manometr Zbiornik Манометр Резервуар Valvola spurgo aria Sortie air vanne Válvula purga de ar Odvzdušňovací...
  • Page 40 8.1 LEGEND ATT+ 060-090 Symbol IT/DE/ES/EN FR/SV/FI/DA PT/NL/NO/PL CS/HU/EL/RU Protezione termica Protection thermique Protecção térmica Tepelná ochrana Thermokontakt Överbelastningsskydd Overbelastingsbeveiliging Túlterhelésvédelem Protector térmico Ylikuormitussuoja Overspenningsvern Προστατευτικό υπερφόρτωσης Overload protector Overbelastningssikring Zabezpieczenie przeciążeniowe Устройство защиты от перегрузкиOchrana proti preťaženiu Trasformatore ausiliari Transformateur auxiliaires Transformadores auxiliares Transformátor pomocná...
  • Page 41: Installation Diagram

    Aria compressa Essiccatore Gruppo by-pass Filtro (filtrazione da 3 micron o inferiore) in ingresso aria dell’essiccatore Serbatoio in posizione A Luftverdichter Trocknereinheit Bypass-Gruppe Filter (mit Filterleistung bis 3 Mikron oder niedriger) nahe am Lufteintritt der Trocknereinheit Tank in Position A Compresor de aire Secador Grupo by-pass...
  • Page 42 8.2 INSTALLATION DIAGRAM ATT+ 060-090 Compressor de ar Secador Grupo de by-pass Filtro (para uma filtragem até 3 mícrones ou inferior) perto da entrada de ar do secador Depósito na posição A Luchtcompressor Droger Omloopleiding-groep Filter (voor filtering tot 3 micron of lager) dichtbij luchtingang droger Reservoir in stand A Luftkompressor Tørker...
  • Page 43: Technical Data

    MIN.- MAX Ambient Temperature Refrigerant Minimum Compressed Energy Weight R513a Desiccant Air - Side section air inlet Compres- Compressed supply air outlet Charge F.L.A. validated sor Oil air inlet (Silicant Working cable for Temperature Lub. During tran- After Gel) Pressure electrical Model spor...
  • Page 44 8.3 TECHNICAL DATA ATT+ 060-090 Thickness (Tank dessicant) Cyclic loading Shell “S” End cap “E” Model Nominal Minimum Nominal Minimum n° Cycles Critical area thickness thickness thickness thickness ATT+ 060 36000 ATT+ 090 36000 It is suggested to control the thickness of the tanks every 10 years unless the local law does not require more frequent controls Material Model P265GH EN 10028-2/...
  • Page 45 MODBUS BASED (0) ANALOG / INTEGER VARIABLES (HOLDING REGISTER) MODBUS CONFIGURATION Description Default "Read/ Variable name BUAD Parity Stop Data Holding Offset Write" Address RATE Bits register digital 40001 Adsorber Inlet Temperature ADInletTemp 40002 Purge Air Temperature PurgeAirTemp 0 = 1200 1 = 1200 40003 Dew Point Temperature...
  • Page 46 SUPERVISOR PARAMETER ATT+ 060-090 MODBUS BASED (0) Digital output DOut_HeaterContactor Digital output DOut_Compressor DIGITAL VARIABLES (READ COILS) Digital output DOut_ValvolaBypass Description Default "Read/ Variable name Digital output DOut_MoistureDrain Address Write" Digital output DOut_ADEVInColumnA Supervisor ON/OFF State SupervisorONOFFState Digital output DOut_ADEVInColumnB Air Pressure Switch 1 AirPressureSwitchA Digital output...
  • Page 47: Spare Parts

    COMPONENTS Pos. ATT+ 060 ATT+ 090 Fridge compressor 398H147285 Refrigerant condenser 398H114842 Fan motor 398H381730 Refrigerant filter 398H206218 Hot gas valve kit 398H378613 Heat exchabger 398H472111 Low/High pressure gauge 10 14 398H354042 Inlet Air filter element P030AO P035AO Heater air outlet temperature sensor IRII 398H275893 High pressure switch ET-398H354060...
  • Page 48 8.4 SPARE PARTS ATT+ 060-090 kit ETV Discharge column E321G37+ 483510P0 Electronic control Display control Main disconnector switch Phase monitor Compressor/fan automatic switch/ Electrical heater automatic switch Electrical heater automatic switch Despac adsorbent pack *...
  • Page 49 PREVENTIVE MAINTENANCE MODEL REPLACEMENT CODE COMPONENT DESCRIPTION P030AA P030AO Filter elements + Coil solenoid valve block + block pilot ATT+ 060 12 month SKATT060/V2/12 valvs ET-398H254061 RKK10-K95/V1-V4 P035AA P035AO Filter elements + Coil solenoid valve block + block pilot ATT+ 090 12 month SKATT090/V2/12 valvs...
  • Page 50: Exploded Drawing

    8.5 EXPLODED DRAWING ATT+ 060-090 P6.1 P5.2 P5.1 P3.3 P5.3 P3.2 P3.1 P1.5 P2.2 P1.3 P1.4 P1.1 P2.3 P1.2 P2.1 ATT+ 060-090...
  • Page 51 ATT+ 060-090 ATT+ 060-090 8.5 EXPLODED DRAWING...
  • Page 52 8.5 EXPLODED DRAWING ATT+ 060-090 Air piping Standard Oil filter Air filter A ( 1 : 2 ) B ( 1 : 2 ) MANOMETRO PARKER 20BAR P3D-KBA1AHN P3D-KAB1AHN ATT+ 060 Ac GOMITO 2" MF INOX 398H323740 ITEM DESCRIPTION U.M.
  • Page 53 Air piping By-pass Oil filter Air filter A ( 1 : 2 ) ( 1 : 2 ) MANOMETRO PARKER 20BAR P3D-KBA1AHN P3D-KAB1AHN ATTUATORE ELETTR.SLOOP 230V 2P 398H378764 ATT+ 060 Ac GOMITO 2" MF INOX 398H323740 ITEM DESCRIPTION U.M. PART NUMBER ATT+ 060-090 8.5 EXPLODED DRAWING...
  • Page 54 Air filter Oil filter A ( 1 : 2 ) B ( 1 : 2 ) TUBO RAME Ø6x1 L=100 398H370283 MANOMETRO PARKER 20BAR P3D-KBA1AHN P3D-KAB1AHN ATTACCO RAPIDO DIR.1/8"F x TUBO D.6 3114-06-10 ATTACCO RAP.90° M5 x TUBO D.6 3199-06-19 ATT+ 090 Ac GOMITO 2"...
  • Page 55 Oil filter Air filter TUBO RAME Ø6x1 L=100 398H370283 A ( 1 : 2 ) B ( 1 : 2 ) MANOMETRO PARKER 20BAR P3D-KBA1AHN P3D-KAB1AHN ATTACCO RAPIDO DIR.1/8"F x TUBO D.6 3114-06-10 ATTACCO RAP.90° M5 x TUBO D.6 3199-06-19 ATTUATORE ELETTR.SLOOP 230V 2P...
  • Page 56 8.5 EXPLODED DRAWING ATT+ 060-090 Purge line Drain line Gruppo_conden sante_SPS080-1 GUARNIZIONE FASIT 45x35 398H241315 PORTAGOMMA 1" Fx25 398H334316 PORTAGOMMA 1" Mx20 398H334325 ATT+ 060-090 PORTAGOMMA 1"M x TUBO D.int.25 398H334315P ITEM DESCRIPTION U.M. PART NUMBER...
  • Page 57: Refrigerant Circuit

    THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER HANNIFIN MANUFACTURING - GAS SEPARATION AND FILTRATION DIVISION EMEA.
  • Page 58 THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER HANNIFIN MANUFACTURING - GAS SEPARATION AND FILTRATION DIVISION EMEA.
  • Page 59: Dimensional Drawing

    THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER HANNIFIN MANUFACTURING - GAS SEPARATION AND FILTRATION DIVISION EMEA.
  • Page 60: Wiring Diagram

    8.8 WIRING DIAGRAM ATT+ 060-090 SHEET 1/18...
  • Page 61 Graphical Symbols in according to IEC 60617 destination - destinazione DATE 04/08/2022 Power Circuit ATT+ 60/90 Rev. Manufactured by DRAFT. V.Dante Parker Hannifin Manufacturing S.r.l. Circuito di Potenza Sheet Gas Separation and Filtration Division EMEA CHECK. drawing - disegno First Issue 04/08/2022 V.Dante D.Ardillica Strada Zona Industriale,4 - S.
  • Page 62 COMPRESSORE destination - destinazione DATE 04/08/2022 Power Circuit ATT+ 60/90 Rev. Manufactured by DRAFT. V.Dante Parker Hannifin Manufacturing S.r.l. Circuito di Potenza Sheet Gas Separation and Filtration Division EMEA CHECK. drawing - disegno First Issue 04/08/2022 V.Dante D.Ardillica Strada Zona Industriale,4 - S. Angelo di Piove (PD) Italy...
  • Page 63 SICHERHEITSTHERMOSTAT destination - destinazione DATE 04/08/2022 Power Circuit ATT+ 60/90 Rev. Manufactured by DRAFT. V.Dante Parker Hannifin Manufacturing S.r.l. Circuito di Potenza Sheet Gas Separation and Filtration Division EMEA CHECK. drawing - disegno First Issue 04/08/2022 V.Dante D.Ardillica Strada Zona Industriale,4 - S. Angelo di Piove (PD) Italy...
  • Page 64 5/1D destination - destinazione DATE 04/08/2022 Power Circuit ATT+ 60/90 Rev. Manufactured by DRAFT. V.Dante Parker Hannifin Manufacturing S.r.l. Circuito di Potenza Sheet Gas Separation and Filtration Division EMEA CHECK. drawing - disegno First Issue 04/08/2022 V.Dante D.Ardillica Strada Zona Industriale,4 - S. Angelo di Piove (PD) Italy...
  • Page 65 DATE 04/08/2022 Auxiliary Circuits ATT+ 60/90 Rev. Manufactured by DRAFT. V.Dante Circuito Ausiliario Parker Hannifin Manufacturing S.r.l. Sheet Gas Separation and Filtration Division EMEA CHECK. 04/08/2022 V.Dante drawing - disegno First Issue D.Ardillica Strada Zona Industriale,4 - S. Angelo di Piove (PD) Italy...
  • Page 66 CN18 destination - destinazione DATE 04/08/2022 Circuito Ausiliario ATT+ 60/90 Rev. Manufactured by DRAFT. V.Dante Parker Hannifin Manufacturing S.r.l. Circuito Ausiliario Sheet Gas Separation and Filtration Division EMEA CHECK. drawing - disegno First Issue 04/08/2022 V.Dante D.Ardillica Strada Zona Industriale,4 - S. Angelo di Piove (PD) Italy...
  • Page 67 NOTE1 destination - destinazione DATE 04/08/2022 Auxiliary Circuits ATT+ 60/90 Rev. Manufactured by DRAFT. V.Dante Parker Hannifin Manufacturing S.r.l. Circuito Ausiliario Sheet Gas Separation and Filtration Division EMEA CHECK. drawing - disegno First Issue 04/08/2022 V.Dante D.Ardillica Strada Zona Industriale,4 - S. Angelo di Piove (PD) Italy...
  • Page 68 AVC6200 destination - destinazione DATE 04/08/2022 Auxiliary Circuits ATT+ 60/90 Rev. Manufactured by DRAFT. V.Dante Parker Hannifin Manufacturing S.r.l. Circuito Ausiliario Sheet Gas Separation and Filtration Division EMEA CHECK. drawing - disegno First Issue 04/08/2022 V.Dante D.Ardillica Strada Zona Industriale,4 - S. Angelo di Piove (PD) Italy...
  • Page 69 CN15 3/6C 17/1E AVC6200 destination - destinazione DATE Rev. Manufactured by DRAFT. Parker Hannifin Manufacturing S.r.l. Sheet Gas Separation and Filtration Division EMEA CHECK. drawing - disegno Strada Zona Industriale,4 - S. Angelo di Piove (PD) Italy REV. DATE DESCRIPTION SIGN.
  • Page 70 8.8 WIRING DIAGRAM ATT+ 060-090 SHEET 11/18 EVE6000 EXP1 DIP SWITCH EVE6000 EXP_1 AC/DC ANALOGIC INPUT A2-CN6 A2-CN1 A2-CN3 5V(out) 24V(out) 0,5 mmq 0.75mm2 11.02 11.03 11.04 11.00 11.24 125Kbps 11.24 11.03 11.24 11.04 11.00 4.. 20mA 0..30bar 4.. 20mA 6/7A 7/2D CN6_EXP1...
  • Page 71 SHEET 12/18 EVE6000 EXP1 DIGITAL OUTPUT A2-CN5 DIGITAL INPUT C123 A2-CN2 COM DI 0,5 mmq 1 mmq 12.01 12.02 12.03 12.04 12.05 12.03 12.04 12.05 YV11 YV91 12.06 3/3B 12.06 G230 KA10 6/7B CN2_EXP1 6/7D CN2_EXP1 G230 G230 G230 5/5C 13/4D 230VAC 230VAC...
  • Page 72 8.8 WIRING DIAGRAM ATT+ 060-090 SHEET 13/18 EVE6000 EXP1 DIGITAL OUTPUT A2-CN4 C456 1 mmq 13.01 13.02 13.03 13.01 13.02 13.03 YV92 YV12 G230 G230 12/7D 230VAC 12/7D 230VAC 12/1E 15/1E EVE6000...
  • Page 73 SHEET 14/18 EVE6000 EXP2 DIP SWITCH EVE6000 EXP_2 AC/DC ANALOGIC INPUT A3-CN6 A3-CN1 A3-CN3 5V(out) 24V(out) 0,5 mmq 0,5 mmq 3.01 14.01 14.02 14.03 14.24 125Kbps 3.01 3/3A 14.24 3/3A 6/7B 7/2D CN6_EXP2 6/7E 7/2D 4.. 20mA 4.. 20mA 4.. 20mA CN6_EXP2 0..30bar 0..15bar...
  • Page 74 8.8 WIRING DIAGRAM ATT+ 060-090 SHEET 15/18 EVE6000 EXP2 DIGITAL OUTPUT A3-CN5 DIGITAL INPUT C123 A3-CN2 COM DI 0,5 mmq 1 mmq 15.01 15.02 4/5E 15.03 15.04 15.05 24VDC 15.03 15.04 15.05 KA10 12/4C 6/7B CN2_EXP2 6/7E CN2_EXP2 4/5F 24VDC 13/1E EVE6000...
  • Page 75 SHEET 16/18 EVE6000 EXP2 DIGITAL OUTPUT A3-CN4 C456 1 mmq 16.01 16.02 16.05 16.01 16.02 16.05 YV41 YV42 6/3B 6/3D EVE6000 ATT+ 060-090 8.8 WIRING DIAGRAM...
  • Page 76 8.8 WIRING DIAGRAM ATT+ 060-090 SHEET 17/18 FREE CONTACTS TERMINAL BLOCKS - MORSETTI COLLEGAMENTI CONTATTI PULITI GENERAL ALARM REMOTE ON/OFF ALLARME GENERALE ON/OFF REMOTO RS - 485-AVC6200 DIGITAL OUTPUT A1-CN6 D03- CN19 RS-485-1 A1-CN19 Belden 3105A I max = 1Amp 250Vac 9/1E Togliere il ponte se viene isntallato On/Off Remoto...
  • Page 77 SHEET 18/18 Terminal Block Terminal level down link down level up link up wire down wire up ATT+ 060-090 8.8 WIRING DIAGRAM...
  • Page 78 8.8 WIRING DIAGRAM ATT+ 060-090...
  • Page 80 A division of Parker Hannifin Corporation Parker Hannifin Manufacturing S.r.l. Sede Legale: Via Sebastiano Caboto 1, Palazzina “A” 20094 Corsico (MI) Italy Sede Operativa: Gas Separation and Filtration Division EMEA - Strada Zona Industriale, 435020 S.Angelo di Piove (PD) Italy tel +39 049 971 2111- fax +39 049 9701911 Web-site: www.

This manual is also suitable for:

Att+ 060Att+ 090

Table of Contents