TROUBLE CODE WITH WARNING LIGHT/UNIT
STOPS WELDING BUT IS TURNED ON.
01
02
04
05
OTHER

Troubleshooting

Error Codes

OVER OR UNDER VOLTAGE. Check power input cable for length/size, check input voltage. Run-
ning on poor quality power supply or dirty power from generator.
OVER TEMPERATURE/ DUTY CYCLE EXCEEDED. Allow unit to rest for 15 minutes. Check for
obstacles, clean welder, and heat sinks. Make sure unit is unplugged for 30 minutes before opening
up for cleaning.
OVER CURRENT. Check to make sure input power cable is correct length and size. Internal unit
fault or low input voltage. Possible issue running on generator with dirty power. Identify cause,
plug directly into the receptacle. Cycle the switch one time. If the code does not clear, call Everlast
Tech Support.
TORCH SWITCH IS STUCK CLOSED. This simply means that the arc has been trying to start and
the HV start has been cycled on for too long. If this does not clear after releasing the foot pedal,
turn off welder immediately and check torch switch for stuck contact. Check foot pedal for com-
plete return or stuck micro-switch. Do not hold down the switch or pedal without attempting to
strike an arc. Doing so for more than 2 seconds without starting will cause this error code. If this
does not correct the issue, increase start time found in back ground menu.