Performance Characteristics - Endress+Hauser Proline Teqwave MW 300 Operating Instructions Manual

Total solids measurement via microwave transmission hart
Table of Contents

Advertisement

Proline Teqwave MW 300 HART
Cable entries
Pin assignment, device plug
Cable specification
Overvoltage protection
Accuracy of outputs
Endress+Hauser
• Cable gland: M20 × 1.5 with cable ⌀ 6 to 12 mm (0.24 to 0.47 in)
• Thread for cable entry:
• NPT ½"
• G ½"
• M20
Optional: M12 device plug for connection to the service interface
Order code for "Accessories mounted", option NB: "Adapter RJ45 M12 (service
interface)"→  175
Service interface for pin assignment, device plug
Order code for "Accessories mounted", option NB: Adapter RJ45 M12 (service interface)
Pin
2
1
2
1
3
3
4
4
Coding
A0032047
→  33
Mains voltage fluctuations
Overvoltage category
Short-term, temporary overvoltage
Long-term, temporary overvoltage
16.6

Performance characteristics

The outputs have the following base accuracy specifications.
Current output
Accuracy
±5 µA
Pulse/frequency output
Accuracy
Max. ±50 ppm of the measured value (over the entire ambient temperature
range)
+
+
-
-
D
→  174
Overvoltage category II
Between cable and ground up to 1200 V, for max. 5 s
Between cable and ground up to 500 V
Technical data
Assignment
Tx
Rx
Tx
Rx
Plug/socket
Socket
175

Advertisement