SenseFace 3 Series
Version: 1.0
Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the
actual product and the written information in this manual.

Advertisement

Table of Contents
loading

Summary of Contents for ZKTeco SenseFace 3 Series

  • Page 1 Quick Start Guide SenseFace 3 Series Version: 1.0 Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual.
  • Page 2 1.Overview 0.98"(25.0mm) Microphone Camera Near-Infrared Flash 2.8-inch Touch Screen Fingerprint Sensor Card Reading Area 2.48"(63.0mm) Reset USB Interface Speaker Tamper Switch Note: Not all products have the function with , the real product shall prevail. Terminal Block...
  • Page 3: Installation Environment

    2.Installation Environment INSTALL INDOORS AVOID INSTALLATION AVOID DIRECT AVOID USE OF ANY ONLY NEAR SUNLIGHT HEAT SOURCE GLASS WINDOWS AND EXPOSURE NEAR THE DEVICE 3.Device Installation Install on the wall Attach the mounting template sticker to the wall, and drill holes according to ① the mounting paper.
  • Page 4: Standalone Installation

    4.Standalone Installation Exit button Wiegand Smoke Door Sensor Detector Card Reader Wireless Doorbell RS485 Lock RS485 Reader ZKBio CVAccess TCP/IP 5.Terminal Block Network Interface Power In Auxiliary Input Lock Exit Button Door Sensor 485B RS485 485A Wiegand Out / In 12VOUT Power Out...
  • Page 5: Ethernet Connection

    6.Ethernet Connection Establish the connection between the device and the software using an Ethernet cable. An illustrative example is provided below: ZKBio CVAccess Default IP address: 192.168.1.201 IP address: 192.168.1.130 Subnet mask 255.255.255.0 Subnet mask : 255.255.255.0 Tap on to enter the main menu. And then click on [Comm.] > [Ethernet] > [IP Address] to input the IP address.
  • Page 6 8.Exit Button, Door Sensor & Auxiliary Connection +12V DC Smoke Detector Exit button Door Sensor 9.RS485 Connection 485+ 485B 485- 485A +12V 12VOUT RS485 Reader...
  • Page 7: Lock Relay Connection

    10.Lock Relay Connection The system supports both Normally Opened Lock and Normally Closed Lock. The NO LOCK (normally opened at power on) is connected with 'NO' and 'COM' terminals, and the NC LOCK (normally closed at power on) is connected with 'NC' and 'COM' terminals.
  • Page 8: User Registration

    12.User Registration Click to enter the Main Menu screen. When a super administrator is set up, administrator verif ication is required when entering the menu. For security purposes, it is recommended to register a super administrator when using it for the f irst time. Method 1: Registering on the device Click >...
  • Page 9 Method 2: Register on ZKBio CVAccess software Please set the IP address and cloud service server address in the COMM. menu option on the device. Click [Access] > [Access Device] > [Device] > [Search] to search the device on the software. When an appropriate server address and port is set on the device, the searched devices are displayed automatically.
  • Page 10 Method 3: Register on the phone Once the ZKBio CVAccess software is installed, the users could enroll their face via a browser application on their own mobile phone. Click [Personnel] > [Parameters], input ‘’http://Server address: Port’’ in the QR Code URL bar. The software will automatically generate a QR code. Scan the QR code or login onto ‘’http://Server address: Port/app/v1/adreg’’...
  • Page 11 13.Ethernet and Cloud Server Settings Click > [ COMM. ] > [ Ethernet ] to set the network parameters. If the TCP/IP communication of the device is successful, the icon will be displayed in the upper right corner of the standby interface. Click >...
  • Page 12 14.Con guring Wi-Fi ★ Tap on to view the menu. Click [COMM.] > [Wi-Fi Settings] to configuring Wi-Fi. When Wi-Fi is enabled, select the searched network. Enter the password, and click Connect to Wi-Fi (OK). The connection succeeds, with icon displayed on the status bar.
  • Page 13: Sip Settings

    After a successful pairing, clicking the icon of the device will ring the wireless doorbell. Note: Generally, each device connects to one wireless doorbell. 16.SIP Settings Setting call options on the device Click >[Intercom] > [SIP Settings] > [Call Options] to set the SIP common parameters.
  • Page 14 Network Accounts 1. Connection Mode Static IP Network 192.168.163.199 2. IP Address Security 255.255.255.0 3. Mask Maintenance 192.168.163.1 4. Gateway Device 5. Primary DNS 114.114.114.114 6. Secondary DNS 8.8.8.8 2. Click icon on the standby page to enter the call page, users can call the IP address of the indoor station.
  • Page 15 Enter Device Number Direct Calling Mode Click >[Intercom] > [SIP Settings] > [Contact List]. Cl ick [Add], input device number and call address to add a new contact member. Note: Call address and the device must be in the same network segment. Click [SIP Settings] >...
  • Page 16 Mode 2: SIP Server Click >[Intercom] > [SIP Settings] > [Local Settings] to enable the SIP server. Click [Master Account Setting] / [Backup Account Setting] to set the SIP server parameters. Click icon on the standby page to enter the call page, once the SIP is set up correctly, a green dot will appear in the upper right corner of the call page to indicate that the device is connected to the server.
  • Page 17: Onvif Settings

    17.ONVIF Settings This function needs to be used with the Network Video Recorder (NVR). Set the device to the same network segment as the NVR. Click > [Intercom] > [ONVIF Settings] to set the User Name and Password. Note: If the Authentication function is disabled, then there is no need to input the User Name and Password when adding the device to the NVR.
  • Page 18 Select the checkbox for the device you want to add and edit the parameters in the corresponding text field, then click on [OK] to add it to the connection list. After successfully adding, the video image obtaining from the device can be viewed in real-time.
  • Page 19 ZKTeco Industrial Park, No. 32, Industrial Road, Tangxia Town, Dongguan, China. Phone : +86 769 - 82109991 : +86 755 - 89602394 www.zkteco.com Copyright 2024 ZKTECO CO., LTD. All Rights Reserved.