  • Page 1 Series Installation Guide Version:1.2.1 Date:Oct. 2010 About this Guide This guide provides actual installation instructions only. For information regarding user instructions, please refer to “iFace Series User Manual”.
  • Page 2: Table Of Contents

    Series Installation Guide Content 1 System Configuration................1 1.1. Notice about installing..............1 1.2. Installation Environment ............3 1.3 View of operation panel.............4 2 The illustration of system construction ...........6 2.1 The illustration of system construction........6 2.2 The sketch map of communication ..........7 3 Installation...................8...
  • Page 3: System Configuration

    Series Installation Guide 1 System Configuration 1.1. Notice about installing This product a mass-produced product. It strictly follows to the criteria of manufacture and inspection of China, U.S.A, and EU. This file contains important information. It is better for you to read it carefully prior to use.
  • Page 4 Series Installation Guide operation. 5. After installation finish, when go to test the exit-door button, please keep a personal in the outside, because sometimes the accidental issue can bring on you are not able to go outside. 6. Our equipment offer an automatically function, please after the installing finish.
  • Page 5: Installation Environment

    Series Installation Guide receiver, and its value is 120Ώ. For other matters not covered in detail herein, please refer to the User Manual, Software Instructions, and appendixes related to this equipment. 1.2. Installation Environment Recommended location: Install the iFace indoors at least 10 feet (3m) away from windows, and 6.5 feet (2m) away from light...
  • Page 6: View Of Operation Panel

    Series Installation Guide 1.3 View of operation panel Front view LED light TFT touch screen Fingerprint Sensor Baseline Integrated Card Module Read Section Touch Keypad Camera Side view Power key Reset...
  • Page 7 Series Installation Guide Back view Battery slot Power TCP/IP connection terminal Loudspeaker...
  • Page 8: The Illustration Of System Construction

    Series Installation Guide 2 The illustration of system construction 2.1 The illustration of system construction...
  • Page 9: The Sketch Map Of Communication

    Series Installation Guide 2.2 The sketch map of communication 1 Fingerprint machine directly connects with PC through RS232 or TCP/IP. TCP/IP or RS232 2 Fingerprint machine connects with PC through RS485 network. RS485 RS485 Switch … RS232 3 Fingerprint machine connects with PC through TCP/IP network.
  • Page 10: Installation

    Series Installation Guide 3 Installation 3.1. Installation Steps 1. Affix the paper template to the wall and drill holes within the three marked circles on the paper template. We recommend affixing the template about four (4) feet (1.2m) above the ground, assuming the average height of your users is 5-6 feet tall(1.5m-1.85m).
  • Page 11: Conect With Other Devices

    Series Installation Guide 3.2 Conect with other devices Caution: Do not to connect peripheral equipment before the power of the device is cut down, otherwise it is possible to damage the device badly. Please follow instruction to connect peripheral equipment。...
  • Page 12 Series Installation Guide The definition of terminal connection : From left to right Tie up Connect to Cable Bell COM2 together Sensor Connect to Door sensor For Door sensor and release Tie up button together Button Connect to Release button...
  • Page 13: Door Sensor Connection

    Series Installation Guide 3.2.1 Door sensor connection The door sensor is used to detect the door open-close state , terminal can monitor if the door has been unauthorized open through the door sensor, at this time it can output a alarm signal, moreover, terminal can trigger prompt warning if the door is not close tightly.
  • Page 14: Time Ring Connection

    Series Installation Guide 3.2.3 Time Ring connection Connect the electrical bell to the fingerprint machine, when arrive the appoint time, the fingerprint machine will send signal to trigger relay。The terminal supports both Normal-Open bells and Normal-Close bells at the same time.
  • Page 15: Door Lock Connection

    Series Installation Guide 3.2.4 Door lock connection The way of installing door lock depends on the type of lock and local condition. Internal resistor which comes from long distance transfer should be taken into consideration when selecting the cable of electric power. The door lock should be installed reliable and stable .Ensure the wiring is correct.
  • Page 16 Series Installation Guide to water or harsh condition, there are some other electric locks available, we don’t recommend you to use them. Connect with electric lock The Normal-Open lock is open when the power is on. The Normal-Close lock is closed when power is on. The machine supports both of the two kinds of locks at the same time.
  • Page 17 Series Installation Guide NC LOCK DC12V Picture1 Power by one supply NO LOCK DC12V Picture2 power by one supply...
  • Page 18 Series Installation Guide Lock Power DC12V NC LOCK Picture 3 The terminal and lock powered by independent adapters NO LOCK DC12V Lock Power Picture 4 The terminal and lock powered by independent adapters Note: Please use the diode FR107 delivered with the equipment as the diode indicated in the figure above.
  • Page 19: Ethernet Connection

    Series Installation Guide 3.2.5 Ethernet connection The background PC software can communicate with device via TCP/IP communication method to exchange data and remotely manage. The terminal provide two ways connect Ethernet. 1) The terminal connect with PC through cross cable。...
  • Page 20: Rs232 Connection

    Series Installation Guide 3.2.6 RS232 connection The background software can communicate with the equipment to upload and download records by the RS232 communication means. Terminal connection definition PC Serial Port iFace iFace PC Serial Port Note:Don’t upload or download facial module through RS232,...
  • Page 21: Rs485 Connection

    Series Installation Guide 3.2.7 RS485 connection When the RS485 is used for networking, the bus network architecture must be used for wiring. Any RS485 communication line consists of a group of twisted pairs, and signal is transferred with help...
  • Page 22: Wiegand Output Connection

    Series Installation Guide 3.2.8 Wiegand Output Connection The equipment provides standard Wiegand26 output, which can be connected to most of the current access controller, in the same way as connecting an IC reader or a password keyboard. Generally, it is preferable to limit the length of any connection line to an access controller within 90 meters.
  • Page 23: Power Connection

    Series Installation Guide 3.2.9 Power Connection The device’s working voltage is DC12V,,with working current 500mA, standby current 50mA has provided two ways to connect power, please select one referring to the actual. 1.Terminal connection, Make sure the connection as the Diagram (Don’t connect the poles in reverse.).
  • Page 24: Fix The Device

    Series Installation Guide 3.3 Fix the device 1. Ensure to plug all the patch correctly? 2. Hang the iFace on the mounting plate (top side first). Please see figure ①. 3. Then secure the iFace to the mounting plate with a screw from below.
  • Page 25: Check After Installation

    Series Installation Guide 4 Check after Installation Upon completion of installation of the whole system, check whether the installation is correct before power-on. Check whether the lock drive and other devices can work normally. For more information, please see the User Manual and Software Instructions.
  • Page 26: Others

    Series Installation Guide 5. Others 5.1 Reset Due to operation error or other accidence, which leads the machine not to work, you can restart machine through reset key。 ① take a small tool which diameter is no more than 2mm。...
  • Page 27: Anti-Dismantle Button

    Series Installation Guide 5.2 Anti-dismantle button Anti-dismantle button is on middle of device, whose function is realized by back-cover pressing the anti-dismantle button. When the device is being dismantled, it will send a alarm signal through the terminal. Anti-dismantle button U flash disk using ①...
  • Page 28: Reserve Battery

    Series Installation Guide USB Port 5.4 Reserve Battery Work principle Before use, make sure the reserve battery is installed properly. Whenever use power supply or reserve battery, you need press power key to turn on the terminal. In normal state, When the...
  • Page 29 Series Installation Guide Battery slot Power key Technical parameter: Charge time Less than 4 H Discharge More then 5.5 H time Working 0℃~50℃ Relative 10%~90% environment humidity Storing Please store the battery when the discharge environment capacity is full.,and the environment is 20℃±5℃。...
  • Page 30 Series Installation Guide Do Not throw batteries into fire or hot battery; Do Not use wire or other metal short the positive and negative terminal.

Table of Contents