CONTENTS | OPERATION GENERAL INfORMATION OPERATION OPERATION General information ��������������������������������������� 14 Safety instructions ���������������������������������������������� 14 Other symbols in this documentation ���������������������� 15 General information Units of measurement ����������������������������������������� 15 Safety �������������������������������������������������������� 15 The chapter "Operation" is intended for appliance users and heat- Intended use �����������������������������������������������������...
OPERATION SAfETY Safety Other symbols in this documentation Note Intended use General information is identified by the symbol shown The appliance is intended for heating and storing domestic hot on the left. water when operating a heat pump with a higher or a high out- f Read these texts carefully.
OPERATION | INSTALLATION CLEANING, CARE AND MAINTENANCE INSTALLATION Cleaning, care and maintenance f Have a contractor regularly check the appliance, the safety assembly and all fitted accessories. f Never use abrasive or corrosive cleaning agents. A damp Safety cloth is sufficient for cleaning all plastic parts. Only a qualified contractor should carry out installation, commis- Signal anode consumption indicator sioning, maintenance and repair of the appliance.
For this, ensure that there is enough space for the Minimum clearances installation task. You can then link the appliance into the heating and DHW system. SBB 600 WP SOL: 9.2.2 Fitting the signal anode Material losses When operating the cylinder without consumption indica- tor, leave the plug in the fitting.
INSTALLATION INSTALLATION Heating or solar installation Water connection and safety assembly f Prior to connecting the heating water lines or the solar ther- 9.2.1 Safety instructions mal system, flush the indirect coils with water. f You may connect both indirect coils to the "heat pump return" Note and "solar flow"...
INSTALLATION COMMISSIONING 10. Commissioning 13. Maintenance 10.1 Initial commissioning WARNING Electrocution Carry out all electrical connection and installation work f Open a draw-off point until the appliance has filled up and in accordance with relevant regulations. the pipework is free of air. f Adjust the flow rate.
INSTALLATION SPECIfICATION 14. Specification 14.1 Dimensions and connections SBB 600 WP SOL SBB 600 WP Cold water inlet Male thread G 1 ¼ A DHW outlet Male thread G 1 ¼ A DHW circulation Male thread G ½ A Heat pump flow Female thread G 1 ½...
Page 9
INSTALLATION SPECIfICATION SBB 800 WP SOL 1010 SBB 800 WP SOL Cold water inlet Male thread G 2 A DHW outlet Male thread G 2 A DHW circulation Male thread G 1 A Heat pump flow Female thread G 1 ½ Heat pump return Female thread G 1 ½...
Page 10
INSTALLATION SPECIfICATION SBB 1000 WP SOL 1010 SBB 1000 WP SOL Cold water inlet Male thread G 2 A DHW outlet Male thread G 2 A DHW circulation Male thread G 1 A Heat pump flow Female thread G 1 ½ Heat pump return Female thread G 1 ½...
In the event of a fault, temperatures of up to 95 °C at 1.0 MPa can occur depending on the type of heat sources used. 14.3 Data table SBB 600 WP SOL SBB 800 WP SOL SBB 1000 WP SOL 235906...