Download Print this page

CDN DTP572 Quick Start Manual page 2

Dual probe thermometer

Advertisement

3. The green BATTERY ICON (
display when the battery is fully charged. The
thermometer will then operate continuously for
approximately 36 hours.
4. Unplug the cable and turn the thermometer on as
described in Section A: On/Off.
OPERATING INSTRUCTIONS
A. On/Off
1. Press and hold the POWER ( ) button for
2 seconds to turn on. The display shows all
segments and the thermometer sounds a beep
and the display flashes all segments before
returning to the last settings used. The default
temperature unit is Fahrenheit (°F). The
thermometer is in Active Mode.
2. Press and hold the POWER ( ) button for
2 seconds to turn off.
B. Low Light Mode
The thermometer automatically enters Low Light
Mode after 10 seconds of inactivity to conserve
power. In Low Light Mode the current temperature
appears dimmed on the display. Press any button
to wake up and enter Active Mode.
C. Auto-Off
The thermometer automatically turns off after
10 minutes of inactivity.
Note:
Auto-off is conditional on having both temperature
readings below 122°F/50°C at the same time, no buttons have
been pressed and the temperature change does not exceed
7.4 °F/3°C.
D. Temperature Scale
Press and hold the UP () button for 2 seconds
to select the temperature reading in Fahrenheit
or Celsius.
°F
or
°C
appears to the right of the
digits in both the PROBE 1 (P1) and PROBE 2 (P2)
portions of display.
E. Temperature Measurement
1. While in Active Mode, press and hold the
POWER ( ) button for 2 seconds to enter the
SETTINGS ICON
Set Mode. The
the display. Each time the POWER ( )
button is pressed, the display changes to:
P1 Set Temp Ø P1 Alert On/Off Ø P2 Set Temp
Ø P2 Alert On/Off Ø Exit Set Mode
Note:
The display will automatically exit the Set Mode and
return to Active Mode after 10 seconds of inactivity.
a. P1 Set Temp
1) When the P1 set temperature is flashing,
press the UP () or DOWN () button
to enter desired temperature from
-58 to +572°F (-50 to +300°C). Press and
hold the button for fast advance.
2) Press POWER ( ) button to confirm the
set temperature and advance to P1 Alert
On/Off.
b. P1 Alert On/Off
1) Press the UP () button to turn the alert on
) appears on the
F. Settings Check
( ) appears on
G. Error Messages
and off for P1.
2) Press POWER ( ) button to confirm the
alert status and advance to P2 Set Temp.
c. P2 Set Temp
1) When the P2 set temperature is flashing,
press the UP () or DOWN () button
to enter desired temperature from -58 to
572°F/-50 to 300°C. Press and hold the
button for fast advance.
2) Press POWER ( ) button to confirm the
set temperature and advance to P2 Alert
On/Off.
d. P2 Alert On/Off
1) Press the UP () button to turn the alert on
and off for P2.
2) Press POWER ( ) button to confirm
the alert status and exit the Set Mode,
returning to Active Mode.
2. Insert the probe tip halfway (at least half the
depth) into the thickest part of the food; making
sure that it is not inserted into a fatty deposit,
gristle, near the bone or the cooking surface.
CAUTION:
Probe may be
a heat resistant glove to touch the stainless steel probe or
sensor cable during or just after cooking.
with bare hands.
3. Gently close the oven door on the sensor cable
and insert the plug into the jack on the right
side of the case. Allow approximately 10 to
15 seconds for the probe tip to get accurate
temperature reading. The probe temperature
appears on the display respective of which
probe it is.
4. When the probe temperature reaches the set
temperature the alert sounds and the probe
temperature reading flashes.
5. Press any button to stop the alert. The reading
flashes until the probe temperature is lower than
the set temperature.
1. Press and hold the DOWN () button for
2 seconds to view the settings for P1.
2. Press the DOWN () button again to view the
settings for P2.
3. Press the DOWN () button again to exit and
return to Active Mode.
Note:
The display will automatically return to Active Mode
after 5 seconds of inactivity.
The DTP572 incorporates visual diagnostic
messages as follows:
1. Three dashes
(– –
–) are displayed when the
probe plug is not inserted into the jack.
2.
HI
or
LO
is displayed when the temperature
being measured is outside the range
of the instrument.
HI
a.
indicates that the temperature is
higher than +572°F (+300°C).
HOT
after use. Always wear
Do not touch