Regeneration Frequency Setup (Models With Softener) - Smeg CWG400B Manual

Professional dishwasher
Table of Contents

Advertisement

6.7 Regeneration frequency setup (models with softener)

6.7.1 Table of parameters
ID
Washing cycles between regenerations
H0
Function off (value set when dishwasher is supplied)
H1
94 washing cycles
H2
83 washing cycles
H3
53 washing cycles
H4
33 washing cycles
H5
27 washing cycles
H6
20 washing cycles
Hardness (°dH German degrees)
Regeneration off
8,5
11
17
22,5
28
33,5
Regeneration cycle duration: 12 minutes
6.7.2 Memorisation procedure
To access the programming menu, proceed as follows:
1) switch the appliance off by pressing the OnOff key
2) Hold down the
3) Use the
key to modify the parameter; H0,H1,H2,H3,H4,H5 and H0 will appear on the display in cyclic
sequence
4) Press the OnOff key to confirm the change and quit programming mode.
With values over 60°dF an external water treatment device must be used and the regeneration frequency
must be set on H00.
Hardness (°dF French degrees)
Regeneration off
keys simultaneously for 6 seconds; H0 appears on the display
and
15
20
30
40
50
60
12 
Setting level
H00
H01
H02
H03
H04
H05
H06

Advertisement