Dishwasher Parameter Modification Procedure; Parameter Programming Procedure; Modifiable Parameters - Smeg CWG400B Manual

Professional dishwasher
Table of Contents

Advertisement

SETTINGS
During start-up, the functions/parameters listed below must be set or adjusted:
A series of operations can be carried out when the dishwasher is first installed to customise it to the user's
requirements. To perform these operations, access "programming mode" as explained below.

6.1 Dishwasher parameter modification procedure:

The two red digits provide the following information:
Appliance off but powered up: all decimal points on both digits
Appliance on: Boiler temperature
Washing phase: Tank temperature
Pause phase: Boiler temperature
Rinse phase: Boiler temperature
Programming phase: See parameter programming section
Error message: See error messages section

6.2 PARAMETER PROGRAMMING PROCEDURE

To access the programming menu, proceed as follows:
1) switch the appliance off with the (OnOff) key
2) Press the
appears on the display
3) Use the
key to select the parameter for modification
4) Press
to display the parameter for modification
5) Modify the parameter by pressing
6) Confirm the change by pressing
7) Select the other parameters for modification in the same way and proceed as described above
8) After setting all the appliance parameters, press the OnOff key to quit.
The modification sequence only considers the parameters declared in the software to be modifiable (letter M
in first column in table). The parameters not featured on the selected model are also ignored.

6.2.1 MODIFIABLE PARAMETERS

This table lists the model choice or cycle and temperature option parameters.
F/M
ID
Description
M
P0
Appliance Type
F
P1
Machine Model
M
P2
Boiler temperature
M
P3
Tank temperature
M
P4
Thermostop option
M
P5
Soft Start option
M
P6
Boiler temperature offset
M
P7
Tank temperature offset
M
P8
Real temperature display
F
P9
Tank probe type
Note P6 and P7: negative numbers are indicated by illumination of both decimal points (e.g.: -12
"1.2.")
6 SETTINGS
key 7 times within 6 seconds.. Wait for the 6 seconds to pass; at the end P0
Min
Max
Default
1
3
1
60C
90C
80C
48C
65C
56C
0
1
1
0
1
1
-20
+20
0
-20
+20
+6
0
1
1
0
1
1
10 
Notes
Construction version
Step 1 degree
Step 1 degree
0=off 1=on
0=off 1=on
Real=measured+Offset
0= filtered, 1= real
Do not modify