6.7 Autostart function 
Set at "on" to start the cycle when the hood is closed. 
Set at "off" for cycle start after confirmation with the start button  
 
6.8  Regeneration frequency setup (models with softener) 
 (Default value: H03; modify the parameter to suit the mains water hardness. 
 At  first  use,  the  salt  tank  has  to  be  filled.  It  is  subsequently  sufficient  simply  to  fill  up  with 
regenerating salt when necessary. 
 
 
 
 
Important: 
During normal operation, the dishwasher will perform 
a  number  of  washing  cycles  while  regeneration  is  in 
progress.  During  this  time  (5‐6  cycles)  the  intake 
water will not be treated, but this will not affect the 
washing quality. 
 
 
With values over 60°f an external water treatment device must be used and the regeneration frequency 
must be set on H00. 
‐ CW 620/630 
Modify the parameter (ON/OFF) by pressing
 
Hardness 
 
(°dH German 
Modify the 
degrees) 
value of the 
Regeneration 
parameter 
by pressing
 
 . 
 
22.5 
 
33.5 
18 
 
Hardness (°dF 
French 
degrees) 
Regeneration off 
off 
8.5 
15 
11 
20 
17 
30 
40 
28 
50 
60 
 . 
Setting 
level 
H00 
H01 
H02 
H03 
H04 
H05 
H06 

Hide quick links: