6.1.3 Rinsing temperature setup
6.1.4 Washing temperature setup
Indicator lights as follows:
6.1.5 Autostart function
Set at "on" to start the cycle when the door is closed.
Set at "off" for cycle start after confirmation with the start button
6.1.6 Regeneration frequency setup (models with softener)
•
Default value: H00; modify the parameter to suit the mains water hardness.
•
Generally H03 will be satisfactory for most users.
•
At first use, the salt tank has to be filled. It is subsequently sufficient simply to fill up with regenerating salt
when necessary.
Regeneration cycle duration: 12 minutes
With values over 60°dF an external water treatment device must be used and the regeneration frequency must be
set on H00.
off;
green;
orange;
Modify the value
of the parameter
by pressing
Modify the value of the parameter by pressing
(Default value: 85°C)
Min. 71°C – max. 85°C
Modify the value of the parameter by pressing
(Default value: 62 °C)
Min. 52°C – max. 62°C
flashing.
Modify the parameter (ON/OFF) by pressing
Hardness
(°dH german
degrees)
Regeneration off
.
8,5
11
17
22,5
28
33,5
10
Hardness
(°dF French
Setting level
degrees)
Regeneration off
15
20
30
40
50
60
.
.
.
H00
H01
H02
H03
H04
H05
H06