6.8 Regeneration frequency setup (models with softener)
(Default value: H03; modify the parameter to suit the mains water hardness.
At first use, the salt tank has to be filled. It is subsequently sufficient simply to fill up with
regenerating salt when necessary.
Regeneration cycle duration: 12 minutes
With values over 60°dF an external water treatment device must be used and the regeneration
frequency must be set on H00.
6.9 tStP (minimum rinsing temperature) function
Set at "on" for minimum rinsing temperature as set; set at "off" for rinsing regardless of boiler
temperature.
If the parameter is set as "off" and hot intake water is not used, the minimum rinsing temperature
might be a few degrees lower than the setting.
If the termostop device is set "off" the rinsing is no longer monitored and the user is responsible
for ensuring that the minimum correct T° are maintained for the tank and boiler. It is particularly
important
to
Also refer to the insufficient washing/drying / foam in tank point of the "troubleshooting" section:
restore T Stop ON and/or connect the appliance to a hot water supply
‐ CW 521/531
Modify the
value of the
parameter by
pressing .
Modify the parameter (ON/OFF) by pressing
check
the
20
Hardness
Hardness (°dF
(°dH
French
German
degrees)
degrees)
Regeneratio
Regeneration
n off
off
8,5
15
11
20
17
30
22,5
40
28
50
33,5
60
intake
water
Setting
level
H00
H01
H02
H03
H04
H05
H06
.
temperature.