Mitsubishi Electric 800 Series Instruction Manual page 31

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

 Filter of terminal 6 input
When giving the speed command or limiting the speed from terminal 6 input, settings of Pr.822 Speed setting filter 1 and
Pr.832 Speed setting filter 2 are valid.
When giving the torque command or limiting the torque from terminal 6 input, settings of Pr.826 Torque setting filter 1 and
Pr.836 Torque setting filter 2 are valid.
When "9999 (initial value)" is set in Pr.822, Pr.832, Pr.826, and Pr.836, Pr.74 Input filter time constant is valid.
For details on Pr.822, Pr.832, Pr.826, Pr.836, and Pr.74, refer to the Instruction Manual (Detailed) of the inverter.
 Calibration and adjustment of terminal 6
When "0" is set in Pr.406, terminal 6 is used for speed command and speed limit inputs, and terminal 2 becomes invalid for
those inputs.
Pr.242 Terminal 1 added compensation amount (terminal 2) becomes valid for terminal 6 and compensation of terminal 6
input is made by terminal 1 input.
Pr.252 Override bias and Pr.253 Override gain become valid for terminal 6, and the override compensation value is set for
terminal 6 input.
Pr.849 Analog input offset adjustment becomes valid for terminal 6 and terminal 6 input is provided with offset.
Refer to the Instruction Manual (Detailed) of the inverter for details of Pr.242, Pr.252, Pr.253 and Pr.849.
 Torque bias of terminal 6
When "6" is set in Pr.406, terminal 6 is used for torque bias input.
Pr.846 Torque bias balance compensation, Pr.847 Fall-time torque bias terminal 1 bias, Pr.848 Fall-time torque bias
5
terminal 1 gain become valid for terminal 6.
31
HIGH RESOLUTION ANALOG INPUT