Motor Thermistor Parameter; Parameter List; Thermistor Setting - Mitsubishi Electric 800 Series Instruction Manual

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

6.3

Motor thermistor parameter

6.3.1

Parameter list

Parameters below are used for motor thermistor interface.
Following parameters are available only when used with FR-A8AZ.
Pr.
Pr. group
*1
G062
Motor temperature feedback reference
326
*1
T620
Motor temperature detection filter
407
*1
H023
Motor thermistor selection
408
*1
M061
Motor temperature detection level
750
*1
M046
Reference motor temperature
751
*1*2
H041
Motor temperature detection calibration (analog input)
C29(925)
*1
Setting can be made only when the FR-A8AZ is mounted.
*2
The parameter number in parentheses is the one for use with the LCD operation panel and the parameter unit.
6.3.2

Thermistor setting

When using the thermistor interface, set Pr.408 Motor thermistor selection according to the motor type.
Its initial value is "0" (SF-V5RUT). Set this parameter according to the motor.
Pr.
Pr. group
408
H023
Motor thermistor selection
Name
Name
Initial value
0
Setting range
0 to 150, 9999
0 to 100 s, 9999
0, 1
0 to 200
1 to 200
0 to 200%
Minimum
setting
Setting range
increments
0
1
1
MOTOR THERMISTOR INTERFACE
Minimum
setting
Initial value
increments
1
9999
1 s
9999
1
0
1
75
1
150
0.1%
100%
Description
SF-V5RUT
SF-V5RUA
39
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a8az

Table of Contents